Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography.

Lars Husmann1, Hatem Alkadhi, Thomas Boehm, Sebastian Leschka, Tiziano Schepis, Pascal Koepfli, Lotus Desbiolles, Borut Marincek, Philipp A Kaufmann, Simon Wildermuth.   

Abstract

The purpose of this study was to evaluate the influence of ejection fraction (EF), stroke volume (SV), heart rate, and cardiac output (CO) on coronary artery opacification with 64-slice computed tomography (CT). Sixty patients underwent, retrospectively, electrocardiography-gated 64-slice CT coronary angiography. Left ventricular EF, SV, and CO were calculated with semi-automated software. Attenuation values were measured and contrast-to-noise ratios (CNRs) were calculated in the proximal right coronary artery (RCA) and left main artery (LMA). Mean EF during scanning was 61.5+/-12.4%, SV was 63.2+/-15.6 ml, heart rate was 62.5+/-11.8 beats per minute (bpm), and CO was 3.88+/-1.06 l/min. There was no significant correlation between the EF and heart rate and the attenuation and CNR in either coronary artery. A significant negative correlation was found in both arteries between SV and attenuation (RCA r=-0.26, P<0.05; LMA r=-0.34, P<0.01) and between SV and CNR (RCA r=-0.26, P<0.05; LMA r=-0.26, P<0.05). Similarly, a significant negative correlation was found between the CO and attenuation (RCA r=-0.42, P<0.05; LMA r=-0.56, P<0.001) and between the CO and CNR (RCA r=-0.39, P<0.05; LMA r=-0.44, P<0.001). The actual hemodynamic status of the patient influences the coronary artery opacification with 64-slice CT, in that vessel opacification decreases as SV and CO increase.

Entities:  

Mesh:

Year:  2006        PMID: 16607499     DOI: 10.1007/s00330-005-0110-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  26 in total

1.  Optimal contrast application for cardiac 4-detector-row computed tomography.

Authors:  Christoph R Becker; Cheng Hong; Andreas Knez; Alexander Leber; Roland Bruening; U Joseph Schoepf; Maximilian F Reiser
Journal:  Invest Radiol       Date:  2003-11       Impact factor: 6.016

2.  Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience.

Authors:  Kai Uwe Juergens; Matthias Grude; David Maintz; Eva Maria Fallenberg; Thomas Wichter; Walter Heindel; Roman Fischbach
Journal:  Radiology       Date:  2003-12-10       Impact factor: 11.105

Review 3.  Parameters affecting bolus geometry in CTA: a review.

Authors:  Filippo Cademartiri; Aad van der Lugt; Giacomo Luccichenti; Paolo Pavone; Gabriel P Krestin
Journal:  J Comput Assist Tomogr       Date:  2002 Jul-Aug       Impact factor: 1.826

Review 4.  Pitfalls, artifacts, and remedies in multi- detector row CT coronary angiography.

Authors:  Hyun Seok Choi; Byoung Wook Choi; Kyu Ok Choe; Donghoon Choi; Kyung-Jong Yoo; Myoung-In Kim; Jinna Kim
Journal:  Radiographics       Date:  2004 May-Jun       Impact factor: 5.333

5.  Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time.

Authors:  Xavier L Hamoir; Thomas Flohr; Vincent Hamoir; Laurent Labaki; Jean-Yves Tricquet; Alain Duhamel; Jacques Kirsch
Journal:  Eur Radiol       Date:  2004-11-24       Impact factor: 5.315

Review 6.  Performance evaluation of a 64-slice CT system with z-flying focal spot.

Authors:  T Flohr; K Stierstorfer; R Raupach; S Ulzheimer; H Bruder
Journal:  Rofo       Date:  2004-12

7.  Global and regional left ventricular function assessment with 16-detector row CT: comparison with echocardiography and cardiovascular magnetic resonance.

Authors:  Liesbeth P Salm; Joanne D Schuijf; Albert de Roos; Hildo J Lamb; Hubert W Vliegen; J Wouter Jukema; Raoul Joemai; Ernst E van der Wall; Jeroen J Bax
Journal:  Eur J Echocardiogr       Date:  2005-08-10

8.  Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time.

Authors:  Shi-Zheng Zhang; Xiu-Hua Hu; Qiao-Wei Zhang; Wen-Xin Huang
Journal:  Eur Radiol       Date:  2005-03-11       Impact factor: 5.315

9.  Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography.

Authors:  D Fleischmann; G D Rubin; A A Bankier; K Hittmair
Journal:  Radiology       Date:  2000-02       Impact factor: 11.105

10.  Time-effectiveness, observer-dependence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT.

Authors:  T Boehm; H Alkadhi; M Roffi; J K Willmann; L M Desbiolles; B Marincek; S Wildermuth
Journal:  Rofo       Date:  2004-04
View more
  29 in total

1.  Shorter delay time reduces interpatient variability in coronary enhancement in coronary CT angiography using the bolus tracking method with 320-row CT.

Authors:  Nobuo Tomizawa; Takeshi Nojo; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2012-04-22       Impact factor: 2.357

2.  Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.

Authors:  Andreas H Mahnken; Annabella Rauscher; Ernst Klotz; Georg Mühlenbruch; Marco Das; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

Review 3.  Cardiac CT: coronary arteries and beyond.

Authors:  Andreas H Mahnken; Georg Mühlenbruch; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-10-26       Impact factor: 5.315

4.  Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggering.

Authors:  Bernhard A Herzog; Lars Husmann; Ines Valenta; Fabian M Tay; Nina Burkhard; Oliver Gaemperli; Christophe A Wyss; Ulf Landmesser; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2009-04-19       Impact factor: 2.357

5.  Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose.

Authors:  Sebastian Leschka; Paul Stolzmann; Florian T Schmid; Hans Scheffel; Bjoern Stinn; Borut Marincek; Hatem Alkadhi; Simon Wildermuth
Journal:  Eur Radiol       Date:  2008-04-08       Impact factor: 5.315

6.  Validation of a new contrast material protocol adapted to body surface area for optimized low-dose CT coronary angiography with prospective ECG-triggering.

Authors:  Aju P Pazhenkottil; Lars Husmann; Ronny R Buechel; Bernhard A Herzog; René Nkoulou; Irene A Burger; Andrea Vetterli; Ines Valenta; Jelena R Ghadri; Patrick von Schulthess; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2010-02-04       Impact factor: 2.357

7.  Coronary CT angiography-derived fractional flow reserve correlated with invasive fractional flow reserve measurements--initial experience with a novel physician-driven algorithm.

Authors:  Stefan Baumann; Rui Wang; U Joseph Schoepf; Daniel H Steinberg; James V Spearman; Richard R Bayer; Christian W Hamm; Matthias Renker
Journal:  Eur Radiol       Date:  2014-11-18       Impact factor: 5.315

8.  A low-dose and an ultra-low-dose contrast agent protocol for coronary CT angiography in a clinical setting: quantitative and qualitative comparison to a standard dose protocol.

Authors:  Dominik C Benz; Christoph Gräni; Beatrice Hirt Moch; Fran Mikulicic; Jan Vontobel; Tobias A Fuchs; Julia Stehli; Olivier F Clerc; Mathias Possner; Aju P Pazhenkottil; Oliver Gaemperli; Ronny R Buechel; Philipp A Kaufmann
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

9.  Coronary 64-slice CT angiography predicts outcome in patients with known or suspected coronary artery disease.

Authors:  Oliver Gaemperli; Ines Valenta; Tiziano Schepis; Lars Husmann; Hans Scheffel; Lotus Desbiolles; Sebastian Leschka; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Eur Radiol       Date:  2008-02-20       Impact factor: 5.315

10.  Biphasic contrast medium injection in cardiac CT: moderate versus high concentration contrast material at identical iodine flux and iodine dose.

Authors:  Annemarieke Rutten; Matthijs F L Meijs; Alexander M de Vos; Peter R Seidensticker; Mathias Prokop
Journal:  Eur Radiol       Date:  2010-03-20       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.