Literature DB >> 28406318

A low-dose and an ultra-low-dose contrast agent protocol for coronary CT angiography in a clinical setting: quantitative and qualitative comparison to a standard dose protocol.

Dominik C Benz1, Christoph Gräni1, Beatrice Hirt Moch1, Fran Mikulicic1, Jan Vontobel1, Tobias A Fuchs1, Julia Stehli1, Olivier F Clerc1, Mathias Possner1, Aju P Pazhenkottil1, Oliver Gaemperli1, Ronny R Buechel1, Philipp A Kaufmann1.   

Abstract

OBJECTIVE: To evaluate the impact of a low-dose (LD) and an ultra-LD (ULD) contrast protocol for coronary CT angiography on qualitative and quantitative image parameters in a clinical setting.
METHODS: We scanned 120 consecutive patients with a 256-slice CT scanner applying a LD (60 patients, 35-55 ml) or ULD (60 patients, 25-45 ml) contrast protocol adapted to the body mass index. Visually assessed image quality and attenuation measured in each coronary segment were retrospectively compared in 20 consecutive patients scanned with a normal-dose (ND, 40-105 ml) contrast protocol.
RESULTS: Visually assessed image quality did not differ significantly among protocols. By contrast, attenuation obtained from the ULD protocol (median contrast volume 35 ml) differed significantly from the LD (median 45 ml) and ND (median 70 ml) protocols in the coronary segments (316 ± 52 vs 363 ± 60 and 359 ± 52 HU, p < 0.001). Attenuation did not differ significantly between the LD and ND protocol. The proportion of patients with inadequate coronary vessel attenuation was significantly higher (p < 0.001) in the ULD protocol (37%) than in the ND (5%) and LD (10%) protocols but did not differ significantly between the ND and LD protocols.
CONCLUSION: In a clinical setting, a LD contrast protocol with a median volume of 45 ml is feasible for the latest generation 256-slice coronary CT angiography as it yields attenuation comparable to a ND protocol. By contrast, the implementation of an ULD protocol remains challenging. Advances in knowledge: Although not perceived by the naked eye, an ULD contrast protocol in a clinical setting yields attenuation below a threshold for diagnostic image quality.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28406318      PMCID: PMC5602183          DOI: 10.1259/bjr.20160933

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  30 in total

1.  Optimal contrast application for cardiac 4-detector-row computed tomography.

Authors:  Christoph R Becker; Cheng Hong; Andreas Knez; Alexander Leber; Roland Bruening; U Joseph Schoepf; Maximilian F Reiser
Journal:  Invest Radiol       Date:  2003-11       Impact factor: 6.016

2.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

3.  Risks and benefits of cardiac imaging: an analysis of risks related to imaging for coronary artery disease.

Authors:  Juhani Knuuti; Frank Bengel; Jeroen J Bax; Philipp A Kaufmann; Dominique Le Guludec; Pasquale Perrone Filardi; Claudio Marcassa; Nina Ajmone Marsan; Stephan Achenbach; Anastasia Kitsiou; Albert Flotats; Eric Eeckhout; Heikki Minn; Birger Hesse
Journal:  Eur Heart J       Date:  2013-12-29       Impact factor: 29.983

4.  Feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in 320-detector row coronary CT angiography.

Authors:  Fuminari Tatsugami; Mitsuru Matsuki; Yuki Inada; Shuji Kanazawa; Go Nakai; Yoshihiro Takeda; Hideaki Morita; Haruhiko Takada; Kenji Ashida; Shushi Yoshikawa; Katsunori Fukumura; Yoshifumi Narumi
Journal:  Acad Radiol       Date:  2009-11-17       Impact factor: 3.173

5.  Coronary enhancement for prospective ECG-gated single R-R axial 320-MDCT angiography: comparison of 60- and 80-mL iopamidol 370 injection.

Authors:  Kanako K Kumamaru; Michael L Steigner; Shigeyoshi Soga; Jason Signorelli; Arash Bedayat; Kimberly Adams; Dimitris Mitsouras; Frank J Rybicki
Journal:  AJR Am J Roentgenol       Date:  2011-10       Impact factor: 3.959

6.  The prognostic implications of further renal function deterioration within 48 h of interventional coronary procedures in patients with pre-existent chronic renal insufficiency.

Authors:  L Gruberg; G S Mintz; R Mehran; G Gangas; A J Lansky; K M Kent; A D Pichard; L F Satler; M B Leon
Journal:  J Am Coll Cardiol       Date:  2000-11-01       Impact factor: 24.094

7.  Feasibility of contrast material volume reduction in coronary artery imaging using 320-slice volume CT.

Authors:  Patrick A Hein; Juliane May; Patrik Rogalla; Craig Butler; Bernd Hamm; Alexander Lembcke
Journal:  Eur Radiol       Date:  2009-12-17       Impact factor: 5.315

8.  Dual-source CT coronary angiography involving injection protocol with iodine load tailored to patient body weight and body mass index: estimation of optimal contrast material dose.

Authors:  Xiaomei Zhu; Yinsu Zhu; Hai Xu; Guanyu Yang; Lijun Tang; Yi Xu
Journal:  Acta Radiol       Date:  2012-11-21       Impact factor: 1.990

9.  High-pitch dual-source CT coronary angiography with low volumes of contrast medium.

Authors:  Alexander Lembcke; Carsten Schwenke; Patrick A Hein; Gesine Knobloch; Tahir Durmus; Bernd Hamm; Alexander Huppertz
Journal:  Eur Radiol       Date:  2013-08-15       Impact factor: 5.315

10.  Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT--a pooled analysis of two randomized trials.

Authors:  Henrik S Thomsen; Sameh K Morcos
Journal:  Eur Radiol       Date:  2008-11-11       Impact factor: 5.315

View more
  6 in total

1.  Performance evaluation of using shorter contrast injection and 70 kVp with deep learning image reconstruction for reduced contrast medium dose and radiation dose in coronary CT angiography for children: a pilot study.

Authors:  Jihang Sun; Haoyan Li; Jianying Li; Yongli Cao; Zuofu Zhou; Michelle Li; Yun Peng
Journal:  Quant Imaging Med Surg       Date:  2021-09

2.  Coronary artery volume index: a novel CCTA-derived predictor for cardiovascular events.

Authors:  Georgios Benetos; Ronny R Buechel; Marisa Gonçalves; Dominik C Benz; Elia von Felten; Georgios P Rampidis; Olivier F Clerc; Michael Messerli; Andreas A Giannopoulos; Cathérine Gebhard; Tobias A Fuchs; Aju P Pazhenkottil; Philipp A Kaufmann; Christoph Gräni
Journal:  Int J Cardiovasc Imaging       Date:  2020-01-01       Impact factor: 2.357

3.  Diagnostic accuracy of coronary opacification derived from coronary computed tomography angiography to detect ischemia: first validation versus single-photon emission computed tomography.

Authors:  Dominik C Benz; Fran Mikulicic; Christoph Gräni; Marvin Grossmann; Andreas A Giannopoulos; Michael Messerli; Catherine Gebhard; Oliver Gaemperli; Ronny R Buechel; Philipp A Kaufmann; Aju P Pazhenkottil
Journal:  EJNMMI Res       Date:  2017-11-25       Impact factor: 3.138

4.  Incidence of contrast-induced acute kidney injury (CI-AKI) in high-risk oncology patients undergoing contrast-enhanced CT with a reduced dose of the iso-osmolar iodinated contrast medium iodixanol.

Authors:  Sebastian Werner; Christian Bez; Clemens Hinterleitner; Marius Horger
Journal:  PLoS One       Date:  2020-05-21       Impact factor: 3.240

Review 5.  Clinical Applications of Wide-Detector CT Scanners for Cardiothoracic Imaging: An Update.

Authors:  Eun Ju Kang
Journal:  Korean J Radiol       Date:  2019-12       Impact factor: 3.500

6.  Contrast medium administration with a body surface area protocol in step-and-shoot coronary computed tomography angiography with dual-source scanners.

Authors:  Liang Jin; Yiyi Gao; Yingli Sun; Cheng Li; Pan Gao; Wei Zhao; Ming Li
Journal:  Sci Rep       Date:  2020-10-07       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.