Literature DB >> 10671582

Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography.

D Fleischmann1, G D Rubin, A A Bankier, K Hittmair.   

Abstract

PURPOSE: To compare the uniformity of aortoiliac opacification obtained from uniphasic contrast medium injections versus individualized biphasic injections at computed tomographic (CT) angiography.
MATERIALS AND METHODS: Thirty-two patients with an abdominal aortic aneurysm underwent CT angiography. In 16 patients (group 1), 120 mL of contrast material was administered at a flow rate of 4 mL/sec. In the other 16 patients (group 2), biphasic injection protocols were computed by using mathematic deconvolution of each patient's time-attenuation response to a standardized test injection. Attenuation uniformity was quantified as the "plateau deviation" of enhancement values, which were calculated as the SD of the time-contiguous attenuation values observed during the 30-second scanning period.
RESULTS: Group 2 patients received between 77 and 165 mL (mean, 115 mL) of contrast medium. Initial flow rates ranged from 4.1 to 10.0 mL/sec (mean, 6.8 mL/sec) for the first 4-6 seconds; continuing flow rates ranged from 2.0 to 4.8 mL/sec (mean, 3.1 mL/sec) for the remaining 24-26 seconds. The plateau deviation was significantly smaller in group 2 patients (19 HU) versus group 1 patients (38 HU, P <.001).
CONCLUSION: At CT angiography, tailored biphasic injections led to more uniform aortoiliac enhancement, compared with standard uniphasic injections of contrast medium.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10671582     DOI: 10.1148/radiology.214.2.r00fe18363

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  37 in total

1.  Measurement of cardiac output from a test-bolus injection in multislice computed tomography.

Authors:  Andreas H Mahnken; Ernst Klotz; Anja Hennemuth; Bettina Jung; Ralf Koos; Joachim E Wildberger; Rolf W Günther
Journal:  Eur Radiol       Date:  2003-08-06       Impact factor: 5.315

Review 2.  Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale.

Authors:  Dominik Fleischmann
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

3.  [CTA of carotid artery with different scanner types].

Authors:  M Lell; K Anders; C Leidecker; W Lang; W Bautz; M Uder
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

4.  Optimisation of contrast medium volume and injection-related factors in CT pulmonary angiography: 64-slice CT study.

Authors:  Selma Uysal Ramadan; Pinar Kosar; Iclal Sonmez; Sevilay Karahan; Ugur Kosar
Journal:  Eur Radiol       Date:  2010-05-01       Impact factor: 5.315

5.  64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model.

Authors:  N-S Holalkere; K Matthes; S P Kalva; W R Brugge; D V Sahani
Journal:  Br J Radiol       Date:  2010-11-16       Impact factor: 3.039

6.  Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.

Authors:  Andreas H Mahnken; Annabella Rauscher; Ernst Klotz; Georg Mühlenbruch; Marco Das; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

Review 7.  Diagnosis of aortic diseases using multidetector computed tomography.

Authors:  Kei Takase; Hideki Ota; Hiroya Rikimaru; Akihiro Sato; Takayuki Yamada; Shuichi Higano; Tadashi Ishibashi; Shoki Takahashi
Journal:  Radiat Med       Date:  2006-06

8.  Preliminary examination to determine the suitable contrast material injection protocol for CT angiography of the pelvis and lower extremities with a multidetector row helical scanner.

Authors:  Minoru Honda; Hideharu Sugimoto; Masao Obuchi; Takashi Narisawa
Journal:  Radiat Med       Date:  2006-05

Review 9.  Cardiac CT: coronary arteries and beyond.

Authors:  Andreas H Mahnken; Georg Mühlenbruch; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-10-26       Impact factor: 5.315

Review 10.  Multidetector computed tomographic angiography of the cardiovascular system.

Authors:  Joshua Burrill; Zaid Dabbagh; Frank Gollub; Mohamed Hamady
Journal:  Postgrad Med J       Date:  2007-11       Impact factor: 2.401

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.