Literature DB >> 17115164

Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.

Andreas H Mahnken1, Annabella Rauscher, Ernst Klotz, Georg Mühlenbruch, Marco Das, Rolf W Günther, Joachim E Wildberger.   

Abstract

The purpose of this study was to evaluate a new algorithm for the prediction of contrast enhancement from test bolus data in cardiac multislice spiral computed tomography (MSCT). An algorithm for the prediction of contrast enhancement using test bolus data was developed. A total of 30 consecutive patients (15 male, 69.5 +/- 9.6 years) underwent cardiac MSCT (12 x 0.75 mm, 120 kV, 500 mAs(eff.)) with a biphasic contrast material injection protocol. Contrast timing was derived from a standard 20 ml test bolus injection. Based on the test bolus time attenuation curves, expected enhancement values were computed for the ascending and descending aorta and the pulmonary trunk and compared with measured data from the cardiac CT scan. At the level of the test bolus measurement in the ascending aorta, the corresponding attenuation values were 309.4 +/- 49.6 Hounsfield Units (HU) for the predicted and 285.6 +/- 42.6 HU for the measured attenuation, respectively. The mean deviation between predicted and measured CT values was 32.8 +/- 48.2 HU (upper and lower limits of agreement 101.4/-53.8 HU), indicating a slight systematic tendency for overestimation. For 80% of the patients the prediction error was less than 50 HU. Prediction of contrast enhancement in cardiac MSCT from test bolus data is feasible with a relatively small mean deviation; 80% of the predictions were within a range that might be acceptable for routine clinical application.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17115164     DOI: 10.1007/s00330-006-0486-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  26 in total

1.  Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection.

Authors:  K Hittmair; D Fleischmann
Journal:  J Comput Assist Tomogr       Date:  2001 Mar-Apr       Impact factor: 1.826

2.  Coronary angiography with multi-slice computed tomography.

Authors:  K Nieman; M Oudkerk; B J Rensing; P van Ooijen; A Munne; R J van Geuns; P J de Feyter
Journal:  Lancet       Date:  2001-02-24       Impact factor: 79.321

3.  Optimal contrast application for cardiac 4-detector-row computed tomography.

Authors:  Christoph R Becker; Cheng Hong; Andreas Knez; Alexander Leber; Roland Bruening; U Joseph Schoepf; Maximilian F Reiser
Journal:  Invest Radiol       Date:  2003-11       Impact factor: 6.016

Review 4.  Parameters affecting bolus geometry in CTA: a review.

Authors:  Filippo Cademartiri; Aad van der Lugt; Giacomo Luccichenti; Paolo Pavone; Gabriel P Krestin
Journal:  J Comput Assist Tomogr       Date:  2002 Jul-Aug       Impact factor: 1.826

5.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

6.  Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience.

Authors:  Stephan Achenbach; Dieter Ropers; Axel Kuettner; Thomas Flohr; Bernd Ohnesorge; Herbert Bruder; Heike Theessen; Meri Karakaya; Werner G Daniel; Werner Bautz; Willi A Kalender; Katharina Anders
Journal:  Eur J Radiol       Date:  2006-01-19       Impact factor: 3.528

7.  Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris.

Authors:  Francesca Pugliese; Nico R A Mollet; Giuseppe Runza; Carlos van Mieghem; Willem B Meijboom; Patrizia Malagutti; Timo Baks; Gabriel P Krestin; Pim J deFeyter; Filippo Cademartiri
Journal:  Eur Radiol       Date:  2005-11-16       Impact factor: 5.315

8.  A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine.

Authors:  P M Joseph; C Ruth
Journal:  Med Phys       Date:  1997-10       Impact factor: 4.071

9.  A PC program for estimating organ dose and effective dose values in computed tomography.

Authors:  W A Kalender; B Schmidt; M Zankl; M Schmidt
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

10.  Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography.

Authors:  D Fleischmann; G D Rubin; A A Bankier; K Hittmair
Journal:  Radiology       Date:  2000-02       Impact factor: 11.105

View more
  8 in total

Review 1.  Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know.

Authors:  Charbel Saade; Ibrahim Alsheikh Deeb; Maha Mohamad; Hussain Al-Mohiy; Fadi El-Merhi
Journal:  Diagn Interv Radiol       Date:  2016 Mar-Apr       Impact factor: 2.630

2.  Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy.

Authors:  Rihyeon Kim; Eun-Ah Park; Whal Lee; Jin Wook Chung
Journal:  Eur Radiol       Date:  2016-02-23       Impact factor: 5.315

3.  Aortic CT angiography using the double region of interest timing bolus technique: feasibility of 80 kVp scanning in lean patients.

Authors:  Nobuo Tomizawa; Shingo Ito; Tastuya Nakao; Hiroaki Arakawa; Kodai Yamamoto; Shinichi Inoh; Takeshi Nojo; Sunao Nakamura
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-02       Impact factor: 2.357

4.  Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography.

Authors:  Harald Seifarth; Michael Puesken; John F Kalafut; Susanne Wienbeck; Johannes Wessling; David Maintz; Walter Heindel; Kai-Uwe Juergens
Journal:  Eur Radiol       Date:  2009-05-08       Impact factor: 5.315

5.  CTPA for the diagnosis of acute pulmonary embolism during pregnancy.

Authors:  Cornelia Schaefer-Prokop; Mathias Prokop
Journal:  Eur Radiol       Date:  2008-09-16       Impact factor: 5.315

6.  Novel contrast-injection protocol for coronary computed tomographic angiography: contrast-injection protocol customized according to the patient's time-attenuation response.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Shinichi Nakamura; Kazuo Awai; Daisuke Utsunomiya; Tomohiro Namimoto; Kazunori Harada; Yasuyuki Yamashita
Journal:  Heart Vessels       Date:  2013-03-20       Impact factor: 2.037

7.  Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography.

Authors:  Sock Keow Tan; Kwan Hoong Ng; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Fadhli Mohamed Sani; Yang Faridah Abdul Aziz; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2019-04

8.  Low contrast media volume in pre-TAVI CT examinations.

Authors:  Madeleine Kok; Jakub Turek; Casper Mihl; Sebastian D Reinartz; Robin F Gohmann; Estelle C Nijssen; Suzanne Kats; Vincent G van Ommen; Bas L J H Kietselaer; Joachim E Wildberger; Marco Das
Journal:  Eur Radiol       Date:  2015-11-11       Impact factor: 5.315

  8 in total