Literature DB >> 22527257

Shorter delay time reduces interpatient variability in coronary enhancement in coronary CT angiography using the bolus tracking method with 320-row CT.

Nobuo Tomizawa1, Takeshi Nojo, Masaaki Akahane, Rumiko Torigoe, Shigeru Kiryu, Kuni Ohtomo.   

Abstract

The purpose was to investigate the influence of shorter delay time on the interpatient variability in coronary enhancement and appropriateness of scan timing in coronary CT angiography (CTA) using bolus tracking method with 320-row CT. The bolus tracking scan was performed at the level of the bifurcation of the trachea for first 50 patients (group 1) and at the center level of the diagnostic scan for the last 50 patients (group 2). The CT number of the proximal coronary arteries was measured in the right coronary artery (RCA) and the left main trunk (LMT). The CT numbers of the right ventricle, left ventricle, ascending aorta, and descending aorta were also measured to consider the appropriateness of the scan timing. The delay time was longer in group 1 than in group 2 (7.0 vs. 2.6 s; p < 0.0001). The CT number within the RCA was 390 ± 75 HU for group 1 and 419 ± 42 HU for group 2. The CT number within the LMT was 396 ± 72 HU for group 1 and 420 ± 40 HU for group 2. The difference of average (p = 0.02 and 0.04) and standard deviation (p = 0.03 and 0.02) was statistically significant. The scan timing was early or late in 15 patients for group 1, but only 2 patients for group 2 (p = 0.0002). Shortening the delay time could reduce the interpatient variability in coronary enhancement with appropriate scan timing in coronary CTA.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22527257     DOI: 10.1007/s10554-012-0045-1

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  22 in total

Review 1.  Current contrast media delivery strategies for cardiac and pulmonary multidetector-row computed tomography angiography.

Authors:  Luis R Ramos-Duran; John F Kalafut; Michael Hanley; U Joseph Schoepf
Journal:  J Thorac Imaging       Date:  2010-11       Impact factor: 3.000

Review 2.  Intravenous contrast medium administration and scan timing at CT: considerations and approaches.

Authors:  Kyongtae T Bae
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

3.  Feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in 320-detector row coronary CT angiography.

Authors:  Fuminari Tatsugami; Mitsuru Matsuki; Yuki Inada; Shuji Kanazawa; Go Nakai; Yoshihiro Takeda; Hideaki Morita; Haruhiko Takada; Kenji Ashida; Shushi Yoshikawa; Katsunori Fukumura; Yoshifumi Narumi
Journal:  Acad Radiol       Date:  2009-11-17       Impact factor: 3.173

4.  Coronary enhancement for prospective ECG-gated single R-R axial 320-MDCT angiography: comparison of 60- and 80-mL iopamidol 370 injection.

Authors:  Kanako K Kumamaru; Michael L Steigner; Shigeyoshi Soga; Jason Signorelli; Arash Bedayat; Kimberly Adams; Dimitris Mitsouras; Frank J Rybicki
Journal:  AJR Am J Roentgenol       Date:  2011-10       Impact factor: 3.959

5.  Influence of hemodynamic parameters on coronary artery attenuation with 320-detector coronary CT angiography.

Authors:  Nobuo Tomizawa; Shuhei Komatsu; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Eur J Radiol       Date:  2011-01-14       Impact factor: 3.528

Review 6.  CT coronary angiography: 256-slice and 320-detector row scanners.

Authors:  Edward M Hsiao; Frank J Rybicki; Michael Steigner
Journal:  Curr Cardiol Rep       Date:  2010-01       Impact factor: 2.931

7.  Intracoronary transluminal attenuation gradient in coronary CT angiography for determining coronary artery stenosis.

Authors:  Jin-Ho Choi; James K Min; Troy M Labounty; Fay Y Lin; Dorinna D Mendoza; Dae Hee Shin; Nikki S Ariaratnam; Sunaina Koduru; Juan F Granada; Thomas C Gerber; Jae K Oh; Hyeon-Cheol Gwon; Yeon Hyeon Choe
Journal:  JACC Cardiovasc Imaging       Date:  2011-11

8.  Can differences in corrected coronary opacification measured with computed tomography predict resting coronary artery flow?

Authors:  Benjamin J W Chow; Malek Kass; Owen Gagné; Li Chen; Yeung Yam; Alexander Dick; George A Wells
Journal:  J Am Coll Cardiol       Date:  2011-03-15       Impact factor: 24.094

9.  Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography.

Authors:  Michael L Steigner; Hansel J Otero; Tianxi Cai; Dimitrios Mitsouras; Leelakrishna Nallamshetty; Amanda G Whitmore; Hale Ersoy; Noah A Levit; Marcelo F Di Carli; Frank J Rybicki
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-29       Impact factor: 2.357

Review 10.  The "post-64" era of coronary CT angiography: understanding new technology from physical principles.

Authors:  Hansel J Otero; Michael L Steigner; Frank J Rybicki
Journal:  Radiol Clin North Am       Date:  2009-01       Impact factor: 2.303

View more
  4 in total

1.  Coronary CT angiography using the second-generation 320-detector row CT: assessment of image quality and radiation dose in various heart rates compared with the first-generation scanner.

Authors:  Nobuo Tomizawa; Eriko Maeda; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2013-05-17       Impact factor: 2.357

2.  Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography.

Authors:  Fabian Stenzel; Matthias Rief; Elke Zimmermann; Johannes Greupner; Felicitas Richter; Marc Dewey
Journal:  Eur Radiol       Date:  2014-03-26       Impact factor: 5.315

3.  Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT.

Authors:  Nobuo Tomizawa; Shigeaki Kanno; Eriko Maeda; Masaaki Akahane; Rumiko Torigoe; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2014-04-28       Impact factor: 2.374

4.  Novel contrast-injection protocol for coronary computed tomographic angiography: contrast-injection protocol customized according to the patient's time-attenuation response.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Shinichi Nakamura; Kazuo Awai; Daisuke Utsunomiya; Tomohiro Namimoto; Kazunori Harada; Yasuyuki Yamashita
Journal:  Heart Vessels       Date:  2013-03-20       Impact factor: 2.037

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.