Literature DB >> 15565317

Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time.

Xavier L Hamoir1, Thomas Flohr, Vincent Hamoir, Laurent Labaki, Jean-Yves Tricquet, Alain Duhamel, Jacques Kirsch.   

Abstract

Our objective was to evaluate the image quality of a 16-slice CT system with a rotation time of 375 ms in the assessment of coronary arteries. One hundred patients underwent iodine-enhanced CT coronary angiography within a single breath hold. Images were reconstructed in diastole, 300, 350, 400, 450, 500 and 550 ms prior to the onset of the next R-wave using absolute reverse retrospective ECG gating. The 15 coronary segments of the AHA classification were consensually reviewed by two radiologists. On the whole, best quality imaging was obtained with reconstruction intervals of -350 ms and -400 ms in high percentages of each segment (P<0.0001). Only 6.2% of the arteries with a diameter greater than or equal to 1.5 mm were not assessable because of extensive calcifications (3.9%), cardiac motion artifacts (1.9%), lack of enhancement (0.2%) and stent artifacts (0.3%). In patients with a heart rate above 70 beats per minute, the percentage of assessable segments decreased to 88%, while at a lower heart rate it increased to 95%. In 61% of the patients, all segments were assessable. In conclusion, this generation of CT technique may allow visualization of coronary arteries with a low percentage of non-assessable segments.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15565317     DOI: 10.1007/s00330-004-2541-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  18 in total

1.  Coronary angiography with multi-slice computed tomography.

Authors:  K Nieman; M Oudkerk; B J Rensing; P van Ooijen; A Munne; R J van Geuns; P J de Feyter
Journal:  Lancet       Date:  2001-02-24       Impact factor: 79.321

Review 2.  Multislice computed tomography of the coronary arteries.

Authors:  Jens Rodenwaldt
Journal:  Eur Radiol       Date:  2003-01-22       Impact factor: 5.315

3.  Noninvasive assessment of coronary artery disease by multislice spiral computed tomography using a new retrospectively ECG-gated image reconstruction technique.

Authors:  Yuichi Sato; Naoya Matsumoto; Masahiko Kato; Fumio Inoue; Toshiyuki Horie; Junji Kusama; Akihiro Yoshimura; Takako Imazeki; Takahiro Fukui; Satoru Furuhashi; Motoichiro Takahashi; Katsuo Kanmatsuse
Journal:  Circ J       Date:  2003-05       Impact factor: 2.993

4.  Multislice CT coronary angiography: evaluation of an automatic vessel detection tool.

Authors:  M Dewey; D Schnapauff; M Laule; A Lembcke; A C Borges; W Rutsch; B Hamm; P Rogalla
Journal:  Rofo       Date:  2004-04

5.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

6.  Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart.

Authors:  T Flohr; B Ohnesorge
Journal:  J Comput Assist Tomogr       Date:  2001 Nov-Dec       Impact factor: 1.826

7.  Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate.

Authors:  K Nieman; B J Rensing; R-J M van Geuns; J Vos; P M T Pattynama; G P Krestin; P W Serruys; P J de Feyter
Journal:  Heart       Date:  2002-11       Impact factor: 5.994

8.  Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality.

Authors:  Christopher Herzog; Nasreddin Abolmaali; Joern O Balzer; Sabine Baunach; Hanns Ackermann; Selami Dogan; Martina B Britten; Thomas J Vogl
Journal:  Eur Radiol       Date:  2002-08-21       Impact factor: 5.315

9.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

10.  Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart.

Authors:  B Jung; A H Mahnken; A Stargardt; J Simon; T G Flohr; S Schaller; R Koos; R W Günther; J E Wildberger
Journal:  Eur Radiol       Date:  2003-10-21       Impact factor: 5.315

View more
  27 in total

1.  Computerized method for evaluating diagnostic image quality of calcified plaque images in cardiac CT: validation on a physical dynamic cardiac phantom.

Authors:  Martin King; Zachary Rodgers; Maryellen L Giger; Dianna M E Bardo; Amit R Patel
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

2.  Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system in 133 patients.

Authors:  Damien Delhaye; Martine Remy-Jardin; Randa Salem; Antoine Teisseire; Chadi Khalil; Valérie Delannoy-Deken; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2006-08-29       Impact factor: 5.315

3.  Congenital anomalies of the coronary arteries: imaging with contrast-enhanced, multidetector computed tomography.

Authors:  Rainer Schmitt; Steffen Froehner; Juergen Brunn; Matthias Wagner; Horst Brunner; Oleg Cherevatyy; Frank Gietzen; Georgios Christopoulos; Sebastian Kerber; Franz Fellner
Journal:  Eur Radiol       Date:  2005-03-09       Impact factor: 5.315

4.  Left ventricular function studied with MDCT.

Authors:  Kai Uwe Juergens; Roman Fischbach
Journal:  Eur Radiol       Date:  2005-08-20       Impact factor: 5.315

5.  Automatic determination of minimal cardiac motion phases for computed tomography imaging: initial experience.

Authors:  Martin H K Hoffmann; Jonathan Lessick; Robert Manzke; Florian T Schmid; Edward Gershin; Daniel T Boll; Shmuel Rispler; Andrik J Aschoff; Michael Grass
Journal:  Eur Radiol       Date:  2005-07-14       Impact factor: 5.315

6.  Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT.

Authors:  Sebastian Leschka; Lars Husmann; Lotus M Desbiolles; Oliver Gaemperli; Tiziano Schepis; Pascal Koepfli; Thomas Boehm; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

7.  Detection of a double right coronary artery with 16-row multidetector computed tomography.

Authors:  Stefan P Lemburg; Soeren A Peters; Michael Scheeler; Volkmar Nicolas; Christoph M Heyer
Journal:  Int J Cardiovasc Imaging       Date:  2006-08-22       Impact factor: 2.357

8.  Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients.

Authors:  Damien Delhaye; Martine Remy-Jardin; Céline Rozel; Catherine Dusson; Alain Wurtz; Valérie Delannoy-Deken; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2006-10-24       Impact factor: 5.315

9.  Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool.

Authors:  M Fawad Khan; Stefan Wesarg; Jessen Gurung; Selami Dogan; Adel Maataoui; Boris Brehmer; Christopher Herzog; Hanns Ackermann; Birgit Assmus; Thomas J Vogl
Journal:  Eur Radiol       Date:  2006-03-10       Impact factor: 5.315

10.  Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris.

Authors:  Francesca Pugliese; Nico R A Mollet; Giuseppe Runza; Carlos van Mieghem; Willem B Meijboom; Patrizia Malagutti; Timo Baks; Gabriel P Krestin; Pim J deFeyter; Filippo Cademartiri
Journal:  Eur Radiol       Date:  2005-11-16       Impact factor: 5.315

View more