Mammographic imaging with a small format CCD-based digital cassette: physical characteristics of a clinical system.

S Vedantham1, A Karellas, S Suryanarayanan, I Levis, M Sayag, R Kleehammer, R Heidsieck, C J D'Orsi.   

Abstract

The physical characteristics of a clinical charge coupled device (CCD)-based imager (Senovision, GE Medical Systems, Milwaukee, WI) for small-field digital mammography have been investigated. The imager employs a MinR 2000 (Eastman Kodak Company, Rochester, NY) scintillator coupled by a 1:1 optical fiber to a front-illuminated 61 x 61 mm CCD operating at a pixel pitch of 30 microns. Objective criteria such as modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), and noise equivalent quanta (NEQ) were employed for this evaluation. The results demonstrated a limiting spatial resolution (10% MTF) of 10 cy/mm. The measured DQE of the current prototype utilizing a 28 kVp, Mo-Mo spectrum beam hardened with 4.5 cm Lucite is approximately 40% at close to zero spatial frequency at an exposure of 8.2 mR, and decreases to approximately 28% at a low exposure of 1.1 mR. Detector element nonuniformity and electronic gain variations were not significant after appropriate calibration and software corrections. The response of the imager was linear and did not exhibit signal saturation under tested exposure conditions.

Entities:  

Mesh:

Year:  2000        PMID: 10984230      PMCID: PMC4280185          DOI: 10.1118/1.1286720

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  A time-delay integration charge-coupled device camera for slot-scanned digital radiography.

Authors:  D W Holdsworth; R K Gerson; A Fenster
Journal:  Med Phys       Date:  1990 Sep-Oct       Impact factor: 4.071

2.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

3.  Restoration of digital multiplane tomosynthesis by a constrained iteration method.

Authors:  U E Ruttimann; R A Groenhuis; R L Webber
Journal:  IEEE Trans Med Imaging       Date:  1984       Impact factor: 10.048

4.  Analysis of clustered microcalcifications by using a single numeric classifier extracted from mammographic digital images.

Authors:  S S Buchbinder; I S Leichter; P N Bamberger; B Novak; R Lederman; S Fields; D J Behar
Journal:  Acad Radiol       Date:  1998-11       Impact factor: 3.173

5.  A genetic algorithm-based method for optimizing the performance of a computer-aided diagnosis scheme for detection of clustered microcalcifications in mammograms.

Authors:  M A Anastasio; H Yoshida; R Nagel; R M Nishikawa; K Doi
Journal:  Med Phys       Date:  1998-09       Impact factor: 4.071

6.  X-ray characterization of breast phantom materials.

Authors:  J W Byng; J G Mainprize; M J Yaffe
Journal:  Phys Med Biol       Date:  1998-05       Impact factor: 3.609

7.  Scanned-projection digital mammography.

Authors:  R M Nishikawa; G E Mawdsley; A Fenster; M J Yaffe
Journal:  Med Phys       Date:  1987 Sep-Oct       Impact factor: 4.071

8.  Effects of undersampling on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems.

Authors:  J T Dobbins
Journal:  Med Phys       Date:  1995-02       Impact factor: 4.071

9.  Image quality control for digital mammographic systems: initial experience and outlook.

Authors:  H Roehrig; T Yu; E Krupinski
Journal:  J Digit Imaging       Date:  1995-05       Impact factor: 4.056

10.  Automated seeded lesion segmentation on digital mammograms.

Authors:  M A Kupinski; M L Giger
Journal:  IEEE Trans Med Imaging       Date:  1998-08       Impact factor: 10.048

View more
  13 in total

1.  Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

2.  Solid-state fluoroscopic imager for high-resolution angiography: physical characteristics of an 8 cm x 8 cm experimental prototype.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan; Steven K Onishi
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

3.  Effects of exposure equalization on image signal-to-noise ratios in digital mammography: a simulation study with an anthropomorphic breast phantom.

Authors:  Xinming Liu; Chao-Jen Lai; Gary J Whitman; William R Geiser; Youtao Shen; Ying Yi; Chris C Shaw
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

4.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

5.  Visibility of microcalcification in cone beam breast CT: effects of X-ray tube voltage and radiation dose.

Authors:  Chao-Jen Lai; Chris C Shaw; Lingyun Chen; Mustafa C Altunbas; Xinming Liu; Tao Han; Tianpeng Wang; Wei T Yang; Gary J Whitman; Shu-Ju Tu
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

6.  Comparison of two detector systems for cone beam CT small animal imaging - a preliminary study.

Authors:  Yang Meng; Chris C Shaw; Xinming Liu; Mustafa C Altunbas; Tianpeng Wang; Lingyun Chen; Shu-Ju Tu; S Cheenu Kappadath; Chao-Jen Lai
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-03-02

7.  Comparison of slot scanning digital mammography system with full-field digital mammography system.

Authors:  Chao-Jen Lai; Chris C Shaw; William Geiser; Lingyun Chen; Elsa Arribas; Tanya Stephens; Paul L Davis; Geetha P Ayyar; Basak E Dogan; Victoria A Nguyen; Gary J Whitman; Wei T Yang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

8.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

9.  Dual resolution cone beam breast CT: a feasibility study.

Authors:  Lingyun Chen; Youtao Shen; Chao-Jen Lai; Tao Han; Yuncheng Zhong; Shuaiping Ge; Xinming Liu; Tianpeng Wang; Wei T Yang; Gary J Whitman; Chris C Shaw
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

10.  Receiver operating characteristic analysis for the detection of simulated microcalcifications on mammograms using hardcopy images.

Authors:  Chao-Jen Lai; Chris C Shaw; Gary J Whitman; Wei T Yang; Peter J Dempsey; Victoria Nguyen; Mary F Ice
Journal:  Phys Med Biol       Date:  2006-07-26       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.