Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Srinivasan Vedantham1, Andrew Karellas, Sankararaman Suryanarayanan.   

Abstract

Cascaded linear systems based modeling techniques have been used in the past to predict important system parameters that have a direct impact on image quality. Such models are also useful in optimizing system parameters to improve image quality. In this work, detailed analysis of a solid-state fluoroscopic imaging system intended for high-resolution angiography is presented with the use of such a model. The imaging system analyzed through this model uses four 8 x 8 cm three-side buttable interlined charge-coupled devices (CCDs) specifically designed for high-resolution angiography and tiled in a seamless fashion to achieve a field of view (FOV) of 16 x 16 cm. Larger FOVs can be achieved by tiling more CCDs in a similar manner. The system employs a CsI:Tl scintillator coupled to the CCDs by straight (nontapering) fiberoptics and can potentially be operated in 78, 156, or 234 microm pixel pitch modes. The system parameters analyzed through this model include presampling modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE). The results of the simulations performed indicate that DQE(0) in excess of 0.6 is achievable, with the imager operating at 156 microm pixel pitch, 30 frames/s, and employing a 450-microm-thick CsI:Tl scintillator, even at a low fluoroscopic exposure rate of 1 microR/frame. Further, at a nominal fluoroscopic exposure rate of 2.5 microR/frame there was no noticeable degradation of the DQE even at the 78 microm pixel pitch mode suggesting that it is feasible to perform high-resolution angiography hitherto unattainable in clinical practice.

Mesh:

Year:  2004        PMID: 15191318      PMCID: PMC4280104          DOI: 10.1118/1.1689014

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  Self-normalizing method to measure the detective quantum efficiency of a wide range of x-ray detectors.

Authors:  K Stierstorfer; M Spahn
Journal:  Med Phys       Date:  1999-07       Impact factor: 4.071

2.  Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications.

Authors:  L E Antonuk; K W Jee; Y El-Mohri; M Maolinbay; S Nassif; X Rong; Q Zhao; J H Siewerdsen; R A Street; K S Shah
Journal:  Med Phys       Date:  2000-02       Impact factor: 4.071

3.  An experimental comparison of detector performance for computed radiography systems.

Authors:  Ehsan Samei; Michael J Flynn
Journal:  Med Phys       Date:  2002-04       Impact factor: 4.071

4.  Mammographic imaging with a small format CCD-based digital cassette: physical characteristics of a clinical system.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; I Levis; M Sayag; R Kleehammer; R Heidsieck; C J D'Orsi
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

5.  Micro-angiography for neuro-vascular imaging. II. Cascade model analysis.

Authors:  Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2003-11       Impact factor: 4.071

6.  Image quality in two phosphor-based flat panel digital radiographic detectors.

Authors:  Ehsan Samei
Journal:  Med Phys       Date:  2003-07       Impact factor: 4.071

7.  Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

Authors:  J H Siewerdsen; L E Antonuk; Y el-Mohri; J Yorkston; W Huang; I A Cunningham
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

8.  System considerations in CCD-based x-ray imaging for digital chest radiography and digital mammography.

Authors:  S Hejazi; D P Trauernicht
Journal:  Med Phys       Date:  1997-02       Impact factor: 4.071

Review 9.  Transfer function analysis of radiographic imaging systems.

Authors:  C E Metz; K Doi
Journal:  Phys Med Biol       Date:  1979-11       Impact factor: 3.609

10.  A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems.

Authors:  I A Cunningham; M S Westmore; A Fenster
Journal:  Med Phys       Date:  1994-03       Impact factor: 4.071

View more
  18 in total

1.  Solid-state fluoroscopic imager for high-resolution angiography: physical characteristics of an 8 cm x 8 cm experimental prototype.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan; Steven K Onishi
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

2.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Investigation of x-ray spectra for iodinated contrast-enhanced dedicated breast CT.

Authors:  Stephen J Glick; Andrey Makeev
Journal:  J Med Imaging (Bellingham)       Date:  2017-01-26

4.  Comparison of two detector systems for cone beam CT small animal imaging - a preliminary study.

Authors:  Yang Meng; Chris C Shaw; Xinming Liu; Mustafa C Altunbas; Tianpeng Wang; Lingyun Chen; Shu-Ju Tu; S Cheenu Kappadath; Chao-Jen Lai
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-03-02

5.  Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images.

Authors:  Samuel Richard; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

6.  Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

7.  Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: effect of 2D/3D apertures and sampling.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

8.  Accurate MTF measurement in digital radiography using noise response.

Authors:  Andrew Kuhls-Gilcrist; Amit Jain; Daniel R Bednarek; Kenneth R Hoffmann; Stephen Rudin
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

9.  A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.

Authors:  Amit Jain; D R Bednarek; Ciprian Ionita; S Rudin
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

10.  Scaling-law for the energy dependence of anatomic power spectrum in dedicated breast CT.

Authors:  Srinivasan Vedantham; Linxi Shi; Stephen J Glick; Andrew Karellas
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.