X-ray characterization of breast phantom materials.

J W Byng1, J G Mainprize, M J Yaffe.   

Abstract

A pulse-height spectroscopic technique is used to measure the linear attenuation coefficients of commercially available composite phantom materials designed to simulate the attenuation characteristics of breast fat and breast glandular tissue. The manufacturers have specified the composition of these materials with the goal of matching the linear attenuation coefficients of breast tissues, calculated using the mixture rule. Over the energy range 18 to 100 keV, measurements from these materials are in close agreement with manufacturers' predictions and with previously measured linear attenuation coefficients of breast tissue samples.

Mesh:

Substances:

Year:  1998        PMID: 9623665     DOI: 10.1088/0031-9155/43/5/026

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; D Albagli; S Han; E J Tkaczyk; C E Landberg; B Opsahl-Ong; P R Granfors; I Levis; C J D'Orsi; R E Hendrick
Journal:  Med Phys       Date:  2000-03       Impact factor: 4.071

2.  Mammographic imaging with a small format CCD-based digital cassette: physical characteristics of a clinical system.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; I Levis; M Sayag; R Kleehammer; R Heidsieck; C J D'Orsi
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

3.  The myth of the 50-50 breast.

Authors:  M J Yaffe; J M Boone; N Packard; O Alonzo-Proulx; S Y Huang; C L Peressotti; A Al-Mayah; K Brock
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

4.  Validation of a method for measuring the volumetric breast density from digital mammograms.

Authors:  O Alonzo-Proulx; N Packard; J M Boone; A Al-Mayah; K K Brock; S Z Shen; M J Yaffe
Journal:  Phys Med Biol       Date:  2010-05-12       Impact factor: 3.609

5.  Tissue-mimicking phantom materials with tunable optical properties suitable for assessment of diffuse reflectance spectroscopy during electrosurgery.

Authors:  Sara Azizian Amiri; Pieter Van Berckel; Marco Lai; Jenny Dankelman; Benno H W Hendriks
Journal:  Biomed Opt Express       Date:  2022-04-04       Impact factor: 3.562

6.  Comparison study of reconstruction algorithms for prototype digital breast tomosynthesis using various breast phantoms.

Authors:  Ye-seul Kim; Hye-suk Park; Haeng-Hwa Lee; Young-Wook Choi; Jae-Gu Choi; Hak Hee Kim; Hee-Joung Kim
Journal:  Radiol Med       Date:  2015-09-18       Impact factor: 3.469

7.  The impact of calibration phantom errors on dual-energy digital mammography.

Authors:  Xuanqin Mou; Xi Chen; Lijun Sun; Hengyong Yu; Zhen Ji; Lei Zhang
Journal:  Phys Med Biol       Date:  2008-10-20       Impact factor: 3.609

8.  Internal breast dosimetry in mammography: Monte Carlo validation in homogeneous and anthropomorphic breast phantoms with a clinical mammography system.

Authors:  Christian Fedon; Marco Caballo; Ioannis Sechopoulos
Journal:  Med Phys       Date:  2018-06-29       Impact factor: 4.071

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.