| Literature DB >> 36159048 |
Eun-Jeong Bae1, Ji-Hwan Kim2, Joong Yeon Lim3.
Abstract
Background: The purpose of this in vitro study is to fabricate a novel metal-ceramic prosthesis with a porous structure, to compensate for the disadvantages associated with the design of existing prostheses, and to measure the internal fit of this prosthesis. Materials andEntities:
Keywords: Dental crown; internal fit; metal–ceramic restorations; porosity; prosthesis design
Year: 2022 PMID: 36159048 PMCID: PMC9490247
Source DB: PubMed Journal: Dent Res J (Isfahan) ISSN: 1735-3327
Figure 1Set cement gap values. 1: Margin cement gap (10 μm); 2: Extra cement gap (30 μm); 3: Distance to margin line (1000 μm); 4: Smooth distance (200 μm) and thickness of the metal frame was set to 500 μm (sky blue color).
Figure 2Porous frame design process. Three holes in each of the buccal and lingual sides and four holes in the occlusal surface (diameter: 3 mm).
Figure 3(a) Cobalt–chromium porous structure frame; (b) completed crown specimen; (c) porous inside crown; (d) laminating inside crown; (e) casting inside crown.
Figure 4Measurement of internal fit by region (four margins, four axial walls, one occlusal).
Mean and standard deviation descriptive statistics of internal fit (μm) for all groups (n=30)
| Discrepancy | Mean±SD |
| ||
|---|---|---|---|---|
|
| ||||
| PS | NPC | NPS | ||
| BA | 42.68a, b±22.77 | 84.98a±31.56 | 76.30b±33.21 | 0.008 |
| BM | 34.85a, b±24.26 | 148.74a±50.12 | 124.48b±65.00 | 0.000 |
| DA | 36.27a±34.45 | 62.07b±22.36 | 105.67a, b±48.26 | 0.001 |
| DM | 43.47a, b±25.72 | 95.55a±47.25 | 104.73b±51.74 | 0.008 |
| LA | 29.62a, b±17.26 | 80.29a±32.74 | 97.59b±40.44 | 0.000 |
| LM | 46.51a±14.74 | 105.06a, b±49.34 | 58.41b±24.74 | 0.001 |
| MA | 42.51a±22.79 | 66.90b±23.09 | 104.78a, b±38.19 | 0.000 |
| MM | 28.19a, b±20.76 | 96.83a±35.45 | 98.26b±62.76 | 0.001 |
| OD | 76.78a, b±19.74 | 227.46a±56.83 | 276.92b±87.41 | 0.000 |
| Total | 42.32±22.50 | 107.54±38.75 | 121.36±50.19 | |
Statistical significance between groups in rows followed by the same letters, Multiple comparisons, Tukey’s–Honest Significant Difference. BA: Buccal axial wall discrepancy; BM: Buccal margin discrepancy; DA: Distal axial wall discrepancy; DM: Distal margin discrepancy; LA: Lingual axial wall discrepancy; LM: Lingual margin discrepancy; MA: Mesial axial wall discrepancy; MM: Mesial margin discrepancy; OD: Occlusal discrepancy; PS-group: Porous structure selective laser sintering group; NPC-group: No-porous casting group; NPS-group: No-porous selective laser sintering group
Mean and standard deviation of margin and axial wall discrepancies (μm) for all groups
| Discrepancy | PS | NPC | NPS |
|---|---|---|---|
| Margin | 38.26±21.37 | 111.55±45.54 | 96.47±51.06 |
| Axial wall | 37.77±24.32 | 73.56±27.44 | 96.09±40.03 |
PS-group: Porous structure selective laser sintering group; NPC-group: No-porous casting group; NPS-group: No-porous selective laser sintering group
Figure 5Internal fit as measured using a digital microscope (100×). (a) Margin; (b) margin discrepancy measurement; (c) axial wall; (d) occlusal.