Literature DB >> 19782828

Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns.

Yurdanur Ucar1, Tolga Akova, Musa S Akyil, William A Brantley.   

Abstract

STATEMENT OF PROBLEM: Difficulties encountered during casting of base metal dental alloys limit their use. Application of these alloys might be enhanced if new techniques are used.
PURPOSE: The purpose of this study was to compare the internal fit of laser-sintered Co-Cr alloy crowns with base metal restorations prepared from another Co-Cr alloy and a Ni-Cr alloy using conventional casting techniques.
MATERIAL AND METHODS: Internal fit of laser-sintered Co-Cr crowns was compared with the fit of conventionally cast Ni-Cr and Co-Cr alloy crowns. Twelve crown-shaped specimens were prepared on a stainless steel die representing a prepared maxillary right central incisor for each group. Fit of crowns was evaluated using 2 different techniques: (1) weighing the light-body addition silicone that simulated a cement material, and (2) measuring the internal gap width on a die for longitudinally sectioned specimens. One-way ANOVA followed by Tukey multiple comparison test was used for statistical analysis (alpha=.05).
RESULTS: Significantly higher mean (SD) light-body silicone weights (P<.001) were observed in the laser-sintered Co-Cr alloy group (14.34 (1.67) mg) compared to the conventionally cast Ni-Cr alloy group (9.36 (1.97) mg) and Co-Cr alloy group (7.85 (1.19) mg). Mean internal gap widths (SDs) were 58.21 (19.92) microm, 50.55 (25.1) microm, and 62.57 (21.62) microm, respectively, for the cast Ni-Cr and Co-Cr alloy groups and the laser-sintered Co-Cr alloy group. No significant difference was observed between the 3 groups for internal gap widths (P=.42).
CONCLUSIONS: Weighing the light-body addition silicone is a convenient method for evaluating the 3-dimensional internal fit of dental crowns. However, no significant difference was found among the 3 alloy groups evaluated for the internal gap width of sectioned crown specimens.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19782828     DOI: 10.1016/S0022-3913(09)60165-7

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  39 in total

1.  Evaluation of fit of cement-retained implant-supported 3-unit structures fabricated with direct metal laser sintering and vacuum casting techniques.

Authors:  Raquel Castillo Oyagüe; Andrés Sánchez-Turrión; José Francisco López-Lozano; Javier Montero; Alberto Albaladejo; María Jesús Suárez-García
Journal:  Odontology       Date:  2011-11-11       Impact factor: 2.634

Review 2.  Direct metal laser sintering: a digitised metal casting technology.

Authors:  K Vijay Venkatesh; V Vidyashree Nandini
Journal:  J Indian Prosthodont Soc       Date:  2013-02-05

3.  Retention strength between veneering resin composites and laser-sintered cobalt-chromium alloy.

Authors:  Kohji Kamada; Yohsuke Taira; Tadateru Sumi; Takashi Sawase
Journal:  Odontology       Date:  2016-06-20       Impact factor: 2.634

4.  Adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by selective laser melting technique.

Authors:  Ye Ye; Ting Jiao; Jiarui Zhu; Jian Sun
Journal:  Lasers Med Sci       Date:  2018-01-24       Impact factor: 3.161

5.  Comparative Evaluation of Marginal and Internal Gap of Co-Cr Copings Fabricated from Conventional Wax Pattern, 3D Printed Resin Pattern and DMLS Tech: An In Vitro Study.

Authors:  Eswaran Bhaskaran; N S Azhagarasan; Saket Miglani; T Ilango; G Phani Krishna; B Gajapathi
Journal:  J Indian Prosthodont Soc       Date:  2013-05-03

6.  Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents.

Authors:  Raquel Castillo-de-Oyagüe; Andrés Sánchez-Turrión; José-Francisco López-Lozano; Alberto Albaladejo; Daniel Torres-Lagares; Javier Montero; Maria-Jesús Suárez-García
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-07-01

7.  Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems.

Authors:  Jong-Kyoung Park; Wan-Sun Lee; Hae-Young Kim; Woong-Chul Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

8.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

9.  Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques.

Authors:  Ki-Baek Kim; Jae-Hong Kim; Woong-Chul Kim; Hae-Young Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

10.  Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions.

Authors:  Per Svanborg; Henrik Skjerven; Pablo Carlsson; Alf Eliasson; Stig Karlsson; Anders Ortorp
Journal:  Int J Dent       Date:  2014-03-03
View more