Literature DB >> 26398106

Abutment Material Effect on Peri-implant Soft Tissue Color and Perceived Esthetics.

Aram Kim1, Stephen D Campbell1, Marlos A G Viana1, Kent L Knoernschild1.   

Abstract

PURPOSE: The purpose of this study was to evaluate the effect of implant abutment material on peri-implant soft tissue color using intraoral spectrophotometric analysis and to compare the clinical outcomes with patient and clinician perception and satisfaction.
MATERIALS AND METHODS: Thirty patients and four prosthodontic faculty members participated. Abutments were zirconia, gold-hued titanium, and titanium. Peri-implant mucosa color of a single anterior implant restoration was compared to the patient's control tooth. Spectrophotometric analysis using SpectroShadeTM Micro data determined the color difference (ΔE, ΔL*, Δa*, Δb*) between the midfacial peri-implant soft tissue for each abutment material and the marginal gingiva of the control tooth. Color difference values of the abutment groups were compared using ANOVA (α = 0.05). Patient and clinician satisfaction surveys were also conducted using a color-correcting light source. The results of each patient and clinician survey question were compared using chi-square analysis (α = 0.05). Pearson correlation analyses identified the relationship between the total color difference (ΔE) and the patient/clinician perception and satisfaction, as well as between ΔE and tissue thickness.
RESULTS: Zirconia abutments displayed significantly smaller spectrophotometric gingival color difference (ΔE) compared to titanium and gold-hued titanium abutments (respectively, 3.98 ± 0.99; 7.22 ± 3.31; 5.65 ± 2.11; p < 0.05). Among ΔL*, Δa*, and Δb*, only Δa* (red-green spectrum) showed significant difference between groups. There was no significant correlation between measured soft tissue thickness and ΔE, but thick gingival phenotype, determined by a probe test, demonstrated a smaller ΔE than thin phenotype (4.82 ± 1.49; 6.41 ± 3.27; p = 0.097). There was no statistical difference in patient or clinician satisfaction among abutment materials, and no correlation between ΔE and the patient and clinician satisfaction. Patient satisfaction was significantly higher than clinician, and patient-perceived differences were lower than clinicians' (p < 0.01). Clinicians' satisfaction was higher for gingival (pink) esthetics than crown (white) esthetics (p < 0.05).
CONCLUSIONS: Peri-implant mucosa with zirconia abutments demonstrated significantly lower mean color difference compared to titanium or gold-hued titanium abutments as measured spectrophotometrically; however, no statistical difference in patient or clinician perception/satisfaction among abutment materials was demonstrated. Patients were significantly more satisfied than clinicians.
© 2015 by the American College of Prosthodontists.

Entities:  

Keywords:  Peri-implant soft tissue; clinician perception; implant esthetics; implant restoration; patient satisfaction; titanium abutment; zirconia abutment

Mesh:

Substances:

Year:  2015        PMID: 26398106     DOI: 10.1111/jopr.12360

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  6 in total

1.  [Dental implant restoration abutment selection].

Authors:  Shi Bin; Zeng Hao
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2017-04-01

2.  Impact of abutment material on peri-implant soft tissue color. An in vitro study.

Authors:  Leticia Sala; Antonio Bascones-Martínez; Ana Carrillo-de-Albornoz
Journal:  Clin Oral Investig       Date:  2016-11-22       Impact factor: 3.573

Review 3.  Use of Xenogenic Collagen Matrices in Peri-Implant Soft Tissue Volume Augmentation: A Critical Review on the Current Evidence and New Technique Presentation.

Authors:  Carlo De Annuntiis; Luca Testarelli; Renzo Guarnieri
Journal:  Materials (Basel)       Date:  2022-05-31       Impact factor: 3.748

4.  The color masking ability of a zirconia ceramic on the substrates with different values.

Authors:  Farhad Tabatabaian; Mahdiye Javadi Sharif; Farhood Massoumi; Mahshid Namdari
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-03-15

5.  Evaluation of internal fit of press ceramic and porous structured cobalt-chromium crown fabricated by additive manufacturing.

Authors:  Eun-Jeong Bae; Ji-Hwan Kim; Joong Yeon Lim
Journal:  Dent Res J (Isfahan)       Date:  2022-08-16

Review 6.  The influence of thin as compared to thick peri-implant soft tissues on aesthetic outcomes: A systematic review and meta-analysis.

Authors:  Stefan P Bienz; Miha Pirc; Spyridon N Papageorgiou; Ronald E Jung; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2022-06       Impact factor: 5.021

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.