Literature DB >> 2200878

A standardized method for determination of crown margin fidelity.

J A Sorensen1.   

Abstract

Previous research on crown margin fidelity is reviewed and methods of measurement are compared and scrutinized. A standardized method for the determination of crown margin fidelity is introduced. A biologically oriented rationale is presented for analysis of the measurement parameters. This system places a strong emphasis on measuring factors that impact upon accumulation of plaque and the microbiologic environment around crowns, ultimately affecting gingival health. Crown samples were cemented on master dies and were embedded for sectioning buccolingually and mesiodistally. Photographs of margins with plastic overlays indicating emergence profiles were used to determine vertical and horizontal marginal discrepancies. Three observers measured seven crown systems for the vertical and horizontal marginal discrepancies of each crown system. The interobserver variance was 10 microns for the horizontal and 9 microns for the vertical marginal discrepancy.

Mesh:

Year:  1990        PMID: 2200878     DOI: 10.1016/0022-3913(90)90147-5

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  33 in total

1.  The Effect of Various Finish Line Configurations on the Marginal Seal and Occlusal Discrepancy of Cast Full Crowns After Cementation - An In-vitro Study.

Authors:  Vaishali Nemane; Ravikumar Suryakanth Akulwar; Suresh Meshram
Journal:  J Clin Diagn Res       Date:  2015-08-01

2.  Evaluation of internal and marginal fit of two metal ceramic system - in vitro study.

Authors:  Harish V; Mohamed Ali S A; Jagadesan N; Mohamed Ifthikar; Siva Senthil; Debasish Basak; Febel Huda
Journal:  J Clin Diagn Res       Date:  2014-12-05

3.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

4.  Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents.

Authors:  Raquel Castillo-de-Oyagüe; Andrés Sánchez-Turrión; José-Francisco López-Lozano; Alberto Albaladejo; Daniel Torres-Lagares; Javier Montero; Maria-Jesús Suárez-García
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-07-01

5.  A comparison of marginal fit of glass infiltrated alumina copings fabricated using two different techniques and the effect of firing cycles over them.

Authors:  Hirasankar Bhowmik; Rambhao Parkhedkar
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

6.  Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems.

Authors:  Jong-Kyoung Park; Wan-Sun Lee; Hae-Young Kim; Woong-Chul Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

7.  The effect of porcelain firing and type of finish line on the marginal fit of zirconia copings.

Authors:  Mahroo Vojdani; Anahita Safari; Mina Mohaghegh; Soheil Pardis; Farideh Mahdavi
Journal:  J Dent (Shiraz)       Date:  2015-06

8.  Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns.

Authors:  Nayana Paul; K N Raghavendra Swamy; M R Dhakshaini; Sanjukta Sowmya; M B Ravi
Journal:  J Clin Exp Dent       Date:  2020-01-01

9.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

10.  The marginal and internal discrepancy of zirconia coping milled by two computer-aided design-computer-aided manufacturing systems.

Authors:  Somchai Urapepon
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.