Literature DB >> 22265824

Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility.

Oliver Schaefer1, David C Watts, Bernd W Sigusch, Harald Kuepper, Arndt Guentsch.   

Abstract

OBJECTIVES: The objective of this in vitro study was to visualize and to quantify the marginal and internal fit of heat-pressed ceramic restorations by a novel three-dimensional procedure. Accuracy and reproducibility of the employed measuring method were determined.
METHODS: An acrylic model of a lower left first molar was prepared to receive a partial crown and duplicated by single step dual viscosity impressions. Corresponding working casts were formed from Type IV die stone and indirect restorations were fabricated from heat-pressable lithium disilicate ceramics (IPS e.max Press, Ivoclar Vivadent AG, Schaan, Liechtenstein). The acrylic tooth model and the ceramic partial crowns were digitized by a structure light scanner with a measurement-uncertainty of 4 μm and subjected to computer-aided quality inspection. Visual discrepancies in marginal and internal fit were displayed with colors. For quantitative analysis, mean quadratic deviations (RMS) were computed and analyzed by Student's t-test (n=5, α=0.05).
RESULTS: Mean RMS-values for accuracy (reproducibility) ranged from 34 (14) μm for internal areas to 78 (23) μm for marginal surfaces. Differences in accuracy (p=0.003) and reproducibility (p<0.001) were statistically significant. In general, areas with sharp internal line angles such as occlusal ridges and the preparation finish line exhibited oversized dimensions, whereas areas with rounded and soft internal line angles were undersized. SIGNIFICANCE: The viability of a computer-aided and three-dimensional approach for assessing marginal and internal fit of indirect restorations was demonstrated. Thereby, the obtained results track complex form changes as they occur during laboratory processing.
Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22265824     DOI: 10.1016/j.dental.2011.12.008

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  23 in total

1.  [Influence of trueness for local finish lines of a full crown preparation on that of complete finish line].

Authors:  N Jiang; X D Bao; L Yue
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-09-30

2.  Accuracy of digital and conventional impression techniques and workflow.

Authors:  Paul Seelbach; Cora Brueckel; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2012-10-21       Impact factor: 3.573

3.  Trueness of four different milling procedures used in dental CAD/CAM systems.

Authors:  Corinna Kirsch; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

4.  [Marginal features of CAD/CAM laminate veneers with different materials and thicknesses].

Authors:  Y Li; L Wong; X Q Liu; T Zhou; J Z Lyu; J G Tan
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2022-02-18

5.  Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue.

Authors:  Petra C Guess; Thaleia Vagkopoulou; Yu Zhang; Martin Wolkewitz; Joerg R Strub
Journal:  J Dent       Date:  2013-10-24       Impact factor: 4.379

6.  Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems.

Authors:  Brunna Mota Ferrairo; Fernanda Furtado Piras; Feranda Ferruzzi Lima; Heitor Marques Honório; Marco Antonio Hungaro Duarte; Ana Flávia Sanches Borges; José Henrique Rubo
Journal:  Clin Oral Investig       Date:  2020-08-11       Impact factor: 3.573

7.  White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions.

Authors:  Jin-Hun Jeon; Kyung-Tak Lee; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

8.  Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision.

Authors:  Jin-Hun Jeon; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

9.  Evaluation of marginal fit and internal adaptation of zirconia copings fabricated by two CAD - CAM systems: An in vitro study.

Authors:  Balaji N Rajan; Srinivasan Jayaraman; Baburajan Kandhasamy; Ilangkumaran Rajakumaran
Journal:  J Indian Prosthodont Soc       Date:  2015 Apr-Jun

10.  In vitro evaluation of the marginal and internal discrepancies of different esthetic restorations.

Authors:  Amal Abdelsamad Sakrana
Journal:  J Appl Oral Sci       Date:  2013 Nov-Dec       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.