Literature DB >> 24995593

3D and 2D marginal fit of pressed and CAD/CAM lithium disilicate crowns made from digital and conventional impressions.

Evanthia Anadioti1, Steven A Aquilino, David G Gratton, Julie A Holloway, Isabelle Denry, Geb W Thomas, Fang Qian.   

Abstract

PURPOSE: This in vitro study evaluated the 3D and 2D marginal fit of pressed and computer-aided-designed/computer-aided-manufactured (CAD/CAM) all-ceramic crowns made from digital and conventional impressions.
MATERIALS AND METHODS: A dentoform tooth (#30) was prepared for an all-ceramic crown (master die). Thirty type IV definitive casts were made from 30 polyvinyl siloxane (PVS) impressions. Thirty resin models were produced from thirty Lava Chairside Oral Scanner impressions. Thirty crowns were pressed in lithium disilicate (IPS e.max Press; 15/impression technique). Thirty crowns were milled from lithium disilicate blocks (IPS e.max CAD; 15/impression technique) using the E4D scanner and milling engine. The master die and the intaglio of the crowns were digitized using a 3D laser coordinate measurement machine with accuracy of ±0.00898 mm. For each specimen a separate data set was created for the Qualify 2012 software. The digital master die and the digital intaglio of each crown were merged using best-fitting alignment. An area above the margin with 0.75 mm occlusal-gingival width circumferentially was defined. The 3D marginal fit of each specimen was an average of all 3D gap values on that area. For the 2D measurements, the marginal gap was measured at two standardized points (on the margin and at 0.75 mm above the margin), from standardized facial-lingual and mesial-distal digitized sections. One-way ANOVA with post hoc Tukey's honestly significant difference and two-way ANOVA tests were used, separately, for statistical analysis of the 3D and 2D marginal data (alpha = 0.05).
RESULTS: One-way ANOVA revealed that both 3D and 2D mean marginal gap for group A: PVS impression/IPS e.max Press (0.048 mm ± 0.009 and 0.040 mm ± 0.009) were significantly smaller than those obtained from the other three groups (p < 0.0001), while no significant differences were found among groups B: PVS impression/IPS e.max CAD (0.088 mm ± 0.024 and 0.076 mm ± 0.023), C: digital impression/IPS e.max Press (0.089 mm ± 0.020 and 0.075 mm ± 0.015) and D: digital impression/IPS e.max CAD (0.084 mm ± 0.021 and 0.074 mm ± 0.026). The results of two-way ANOVA revealed a significant interaction between impression techniques and crown fabrication methods for both 3D and 2D measurements.
CONCLUSIONS: The combination of PVS impression method and press fabrication technique produced the most accurate 3D and 2D marginal fits.
© 2014 by the American College of Prosthodontists.

Entities:  

Keywords:  All-ceramic restoration; CAD/CAM; digital impression; marginal fit; technology; triple-scan protocol

Mesh:

Substances:

Year:  2014        PMID: 24995593     DOI: 10.1111/jopr.12180

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  19 in total

1.  Tooth substance removal for ceramic single crown materials-an in vitro comparison.

Authors:  Franz Sebastian Schwindling; Moritz Waldecker; Peter Rammelsberg; Stefan Rues; Wolfgang Bömicke
Journal:  Clin Oral Investig       Date:  2018-12-04       Impact factor: 3.573

2.  Evaluation of the Marginal Fit of CAD/CAM Crowns Fabricated Using Two Different Chairside CAD/CAM Systems on Preparations of Varying Quality.

Authors:  Walter Renne; Bethany Wolf; Raymond Kessler; Karen McPherson; Anthony S Mennito
Journal:  J Esthet Restor Dent       Date:  2015-07-14       Impact factor: 2.843

3.  Trueness of four different milling procedures used in dental CAD/CAM systems.

Authors:  Corinna Kirsch; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

4.  Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance.

Authors:  Mohammad A Atieh; André V Ritter; Ching-Chang Ko; Ibrahim Duqum
Journal:  J Prosthet Dent       Date:  2017-02-17       Impact factor: 3.426

5.  Bonding of Clear Aligner Composite Attachments to Ceramic Materials: An In Vitro Study.

Authors:  Bashair A Alsaud; Maher S Hajjaj; Ahmad I Masoud; Ensanya A Abou Neel; Dalia A Abuelenain; Amal I Linjawi
Journal:  Materials (Basel)       Date:  2022-06-10       Impact factor: 3.748

Review 6.  "Digitally Oriented Materials": Focus on Lithium Disilicate Ceramics.

Authors:  Fernando Zarone; Marco Ferrari; Francesco Guido Mangano; Renato Leone; Roberto Sorrentino
Journal:  Int J Dent       Date:  2016-08-18

7.  Comparison of marginal fit of cemented zirconia copings manufactured after digital impression with lava™ C.O.S and conventional impression technique.

Authors:  Rinet Dauti; Barbara Cvikl; Alexander Franz; Uwe Yacine Schwarze; Bledar Lilaj; Tina Rybaczek; Andreas Moritz
Journal:  BMC Oral Health       Date:  2016-12-08       Impact factor: 2.757

Review 8.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

9.  Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis.

Authors:  Jin-Young Park; So-Yeon Bae; Jae-Jun Lee; Ji-Hwan Kim; Hae-Young Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

10.  Effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin.

Authors:  Renato Roperto; Anna Akkus; Ozan Akkus; Lisa Lang; Manoel Damiao Sousa-Neto; Sorin Teich; Thiago Soares Porto
Journal:  Dent Res J (Isfahan)       Date:  2016 Mar-Apr
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.