Literature DB >> 19178620

Metal-ceramic alloys in dentistry: a review.

Howard W Roberts1, David W Berzins, B Keith Moore, David G Charlton.   

Abstract

PURPOSE: The purpose of this article is to review basic information about the alloys used for fabricating metal-ceramic restorations in dentistry. Their compositions, properties, advantages, and disadvantages are presented and compared. In addition to reviewing traditional noble-metal and base-metal metal-ceramic alloys, titanium and gold composite alloys are also discussed.
MATERIALS AND METHODS: A broad search of the published literature was performed using Medline to identify pertinent current articles on metal-ceramic alloys as well as articles providing a historical background about the development of these alloys. Textbooks, the internet, and manufacturers' literature were also used to supplement this information.
RESULTS: The review discusses traditional as well as more recently-developed alloys and technologies used in dentistry for fabricating metal-ceramic restorations. Clear advantages and disadvantages for these alloy types are provided and discussed as well as the role that compositional variations have on the alloys' performance. This information should enable clinicians and technicians to easily identify the important physical properties of each type and their primary clinical indications.
CONCLUSIONS: A number of alloys and metals are available for metal-ceramic use in dentistry. Each has its advantages and disadvantages, primarily based on its specific composition. Continuing research and development are resulting in the production of new technologies and products, giving clinicians even more choices in designing and fabricating metal-ceramic restorations.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19178620     DOI: 10.1111/j.1532-849X.2008.00377.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  15 in total

1.  Confocal Raman microscopy and SEM/EDS investigations of the interface between the zirconia core and veneering ceramic: the influence of a liner and regeneration firing.

Authors:  Jean-Cédric Durand; Bruno Jacquot; Hamideh Salehi; Jacques Margerit; Frédéric J G Cuisinier
Journal:  J Mater Sci Mater Med       Date:  2012-03-24       Impact factor: 3.896

Review 2.  Additively manufactured metallic biomaterials.

Authors:  Elham Davoodi; Hossein Montazerian; Anooshe Sadat Mirhakimi; Masoud Zhianmanesh; Osezua Ibhadode; Shahriar Imani Shahabad; Reza Esmaeilizadeh; Einollah Sarikhani; Sahar Toorandaz; Shima A Sarabi; Rohollah Nasiri; Yangzhi Zhu; Javad Kadkhodapour; Bingbing Li; Ali Khademhosseini; Ehsan Toyserkani
Journal:  Bioact Mater       Date:  2021-12-30

3.  Air quality in a hospital dental department.

Authors:  Chien-Tien Hsu; Shih-Chang Hsu; Shau-Ku Huang; Chon-Lin Lee; Yi-Shing Shieh
Journal:  J Dent Sci       Date:  2022-04-07       Impact factor: 3.719

4.  Fracture behavior of metal-ceramic fixed dental prostheses with frameworks from cast or a newly developed sintered cobalt-chromium alloy.

Authors:  Klaus-Peter Krug; Andreas W Knauber; Frank P Nothdurft
Journal:  Clin Oral Investig       Date:  2014-03-26       Impact factor: 3.573

5.  Ceramic-Based 4D Components: Additive Manufacturing (AM) of Ceramic-Based Functionally Graded Materials (FGM) by Thermoplastic 3D Printing (T3DP).

Authors:  Uwe Scheithauer; Steven Weingarten; Robert Johne; Eric Schwarzer; Johannes Abel; Hans-Jürgen Richter; Tassilo Moritz; Alexander Michaelis
Journal:  Materials (Basel)       Date:  2017-11-28       Impact factor: 3.623

6.  Evaluation of marginal discrepancy in metal frameworks fabricated by sintering-based computer-aided manufacturing methods.

Authors:  Necati Kaleli; Çağrı Ural; Yeşim Ölçer Us
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

7.  Ion release from three different dental alloys - effect of dynamic loading and toxicity of released elements.

Authors:  Ketil Hegerstrøm Haugli; Morten Syverud; Jan Tore Samuelsen
Journal:  Biomater Investig Dent       Date:  2020-04-24

8.  Comparative Study of the Fit Accuracy of Full-Arch Bar Frameworks Fabricated with Different Presintered Cobalt-Chromium Alloys.

Authors:  Hang-Nga Mai; Tae-Yub Kwon; Min-Ho Hong; Du-Hyeong Lee
Journal:  Biomed Res Int       Date:  2018-08-05       Impact factor: 3.411

9.  Effect of metal conditioner on bonding of porcelain to cobalt-chromium alloy.

Authors:  Yoshito Minesaki; Sadaaki Murahara; Yutaro Kajihara; Yoshihisa Takenouchi; Takuo Tanaka; Shiro Suzuki; Hiroyuki Minami
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

10.  Comparative Analysis of Mechanical Properties and Metal-Ceramic Bond Strength of Co-Cr Dental Alloy Fabricated by Different Manufacturing Processes.

Authors:  Xingting Han; Tomofumi Sawada; Christine Schille; Ernst Schweizer; Lutz Scheideler; Jürgen Geis-Gerstorfer; Frank Rupp; Sebastian Spintzyk
Journal:  Materials (Basel)       Date:  2018-09-22       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.