Literature DB >> 35994520

The performance of using dried blood spot specimens for HIV-1 viral load testing: A systematic review and meta-analysis.

Lara Vojnov1, Sergio Carmona2, Clement Zeh3, Jessica Markby4, Debrah Boeras3, Marta R Prescott1, Anthony L H Mayne5, Souleymane Sawadogo6, Christiane Adje-Toure7, Guoqing Zhang3, Mercedes Perez Gonzalez4, Wendy S Stevens2,8, Meg Doherty4, Chunfu Yang3, Heather Alexander3, Trevor F Peter1, John Nkengasong3.   

Abstract

BACKGROUND: Accurate routine HIV viral load testing is essential for assessing the efficacy of antiretroviral treatment (ART) regimens and the emergence of drug resistance. While the use of plasma specimens is the standard for viral load testing, its use is restricted by the limited ambient temperature stability of viral load biomarkers in whole blood and plasma during storage and transportation and the limited cold chain available between many health care facilities in resource-limited settings. Alternative specimen types and technologies, such as dried blood spots, may address these issues and increase access to viral load testing; however, their technical performance is unclear. To address this, we conducted a meta-analysis comparing viral load results from paired dried blood spot and plasma specimens analyzed with commonly used viral load testing technologies. METHODS AND
FINDINGS: Standard databases, conferences, and gray literature were searched in 2013 and 2018. Nearly all studies identified (60) were conducted between 2007 and 2018. Data from 40 of the 60 studies were included in the meta-analysis, which accounted for a total of 10,871 paired dried blood spot:plasma data points. We used random effects models to determine the bias, accuracy, precision, and misclassification for each viral load technology and to account for between-study variation. Dried blood spot specimens produced consistently higher mean viral loads across all technologies when compared to plasma specimens. However, when used to identify treatment failure, each technology compared best to plasma at a threshold of 1,000 copies/ml, the present World Health Organization recommended treatment failure threshold. Some heterogeneity existed between technologies; however, 5 technologies had a sensitivity greater than 95%. Furthermore, 5 technologies had a specificity greater than 85% yet 2 technologies had a specificity less than 60% using a treatment failure threshold of 1,000 copies/ml. The study's main limitation was the direct applicability of findings as nearly all studies to date used dried blood spot samples prepared in laboratories using precision pipetting that resulted in consistent input volumes.
CONCLUSIONS: This analysis provides evidence to support the implementation and scale-up of dried blood spot specimens for viral load testing using the same 1,000 copies/ml treatment failure threshold as used with plasma specimens. This may support improved access to viral load testing in resource-limited settings lacking the required infrastructure and cold chain storage for testing with plasma specimens.

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35994520      PMCID: PMC9447868          DOI: 10.1371/journal.pmed.1004076

Source DB:  PubMed          Journal:  PLoS Med        ISSN: 1549-1277            Impact factor:   11.613


Introduction

Although an estimated nearly 37 million HIV–positive people are currently eligible for antiretroviral treatment (ART) according to the 2016 WHO Consolidated guidelines on the use of antiretroviral drugs for treating and preventing HIV infection, only 19.5 million people are on ART worldwide [1]. The global community is focused on the goal of achieving universal access to affordable and effective ART with the intention of moving toward elimination of HIV infection. To address this gap, UNAIDS released global HIV targets of 90-90-90, in which the third 90 target represents achieving viral suppression in 90% of those receiving ART. Suppressed or undetectable viral loads improve the health of patients as well as significantly reduce the likelihood of HIV transmission [2-5]. To reach these goals, there is substantial impetus to ensure HIV–positive people receive high-quality care, which includes accurate monitoring of viral load. Accurate routine viral load testing is essential for assessing the efficacy of ART regimens in preventing morbidity, mortality, and transmission as well as treatment adherence and is an indicator of the potential emergence of drug resistance [2,6-13]. Routine viral load testing has also been strongly recommended by WHO as the preferred method for monitoring patients on ART based on evidence indicating that viral load detects ART failure earlier compared to clinical and immunological assessments [14-18]. Testing using plasma separated from EDTA anti-coagulated whole blood has been used in developed countries for many years as the gold standard for treatment monitoring [8,9,11,13]. Unfortunately, the high costs of viral load equipment, the requirement for highly specialized and well-equipped laboratories, and particularly the difficulty of fresh blood specimen collection, storage, and transportation logistics have restricted testing to centralized laboratories and slowed the scale-up of viral load testing in resource-limited countries. Though viral load testing using plasma is the gold standard, alternative specimen types may enable expansion of access to viral load testing in resource-limited countries. Dried blood spot specimens for HIV testing are well established in resource-limited settings and have been routinely used for collecting and shipping early infant HIV diagnosis specimens for testing by polymerase chain reaction in centralized laboratories. They are beneficial as they do not require centrifuges, refrigerators, or freezers at the specimen collection site, can be stored and transported for weeks at ambient temperature, and require a simple finger-prick or heel-stick blood specimen that can be prepared by lower cadres of health care facility staff. Similar benefits could be achieved by using dried blood spot specimens for viral load testing programs in resource-limited settings. Dried blood spot specimens for viral load testing using nucleic acid-based detection methods utilize whole blood as the input specimen, which can result in extraction and detection of intracellular HIV proviral DNA and cell-associated HIV RNA in addition to the biomarker target of free viral RNA circulating in the plasma. Due to this potential over-quantification of HIV nucleic acids using dried blood spot specimens, the 2013 WHO Consolidated ART Guidelines recommended a higher threshold of 3,000 to 5,000 copies/ml to identify treatment failure using dried blood spot specimens, while maintaining a threshold of 1,000 copies/ml to identify treatment failure with plasma specimens [18]. The uncertainty of the performance of dried blood spot specimens for viral load testing has triggered significant interest and controversy as countries are contemplating the scale-up of viral load testing using dried blood spot specimens. Individual studies conducted to date comparing the performance of dried blood spot specimens to plasma on viral load technologies have not provided a consistent picture of performance to inform testing policy [19-69]. Additionally, differences in analytical approaches between studies have made it difficult to compare the data on key criteria such as clinical misclassification and dried blood spot specimen performance at lower thresholds as these have not been presented consistently. This study is a systematic review and meta-analysis using primary data from studies reporting on the currently available viral load technologies and a standardized analysis methodology to better understand the performance and limitations of this specimen collection type across all commonly used viral load testing platforms.

Materials and methods

Search strategy

Fig 1 shows a PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) diagram demonstrating the study selection and data acquisition process [70]. An initial search was conducted on May 29, 2013 in the PubMed, EMBASE, Google Scholar, and Medline databases to identify peer-reviewed original research with appropriate data for this systematic review and meta-analysis. Conference abstracts within the search dates from the Conference on Retroviruses and Opportunistic Infections (CROI), International Conference on AIDS and STIs in Africa (ICASA), International AIDS Society (IAS), and AIDS Conferences as well as extensive bibliography and gray literature were screened for possible inclusion. Only English titles and manuscripts were included. A full final search was conducted again on April 20, 2018 (S1 Fig). For inclusion, studies must have compared viral load values using dried blood spot and plasma specimens measured by 1 or more of the following 6 commonly used technologies—Abbott RealTime HIV-1 on the m2000 platform (Abbott Molecular, Abbott Park, Illinois, United States of America), Generic HIV Charge Virale (Biocentric, Bandol, France), bioMérieux NucliSENS EasyQ HIV-1 v2.0 (bioMérieux, Craponne, France), Hologic Aptima (Hologic, Marlborough, Massachusetts, USA), Roche Amplicor HIV-1 Monitor Test, v1.5 or COBAS Ampliprep/COBAS TaqMan HIV-1 Test, v2.0 using both specimen preextraction reagent (SPEX) and free virus elution (FVE) dried blood spot specimen protocols (Roche Molecular Systems, Basel, Switzerland), and Siemens VERSANT HIV-1 RNA 1.0 assay (kPCR) (Siemens Healthcare Diagnostics, Munich, Germany). Search terms included “dried blood spot,” “plasma,” “technical performance,” “comparison,” “evaluation,” “viral load testing,” and each of the proprietary respective technology names.
Fig 1

PRISMA flow chart.

Study selection

Studies were included if they included technical evaluation data comparing dried blood spot samples to plasma, were pertaining to viral load testing, and were performed using HIV–positive blood. Studies were excluded if they used spike blood samples or panels, compared dried blood spot samples to plasma with a different assay, performed a qualitative analysis of dried blood spot samples, or the comparator was a sample type other than plasma. Sixty studies were identified through online searches and expert notification (Fig 1). We contacted the corresponding authors of all studies that met the inclusion criteria to explain the analysis plan and request original data and obtained original data from 4 studies that were not yet published. For the meta-analysis, a total of 40 studies provided 45 data sets across the 6 technologies resulting in a total of 10,831 paired dried blood spot and plasma viral load results. Correction factors were applied as suggested by the manufacturers for the Hologic Aptima and Roche COBAS TaqMan FVE technologies. Due to the discontinuation of the Roche Amplicor HIV-1 Monitor test, v1.5, data using this technology were excluded from the analysis. Study characteristics were extracted from each manuscript or through author contact.

Quality assessment

The Standards for Reporting Studies of Diagnostic Accuracy (STARD) criteria and Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) were followed and each study graded for quality [71,72]. The PRISMA reporting guideline was followed (S1 PRISMA Checklist).

Statistical analyses

All analyses performed were prespecified in the protocol. Study variables analyzed for each study included study sample size, viral load mean and median, proportion of patient specimens within specific viral load ranges, and sensitivity and specificity. Sensitivity was calculated as the proportion of dried blood spot specimens correctly identified as failing or above the defined treatment failure threshold. Specificity was calculated as the proportion of dried blood spot specimens correctly identified as not failing or below the treatment failure threshold. Forest plots were developed to analyze the between-study heterogeneity of diagnostic performance for each technology. Primary data were then pooled to analyze the performance of dried blood spot specimens for each technology. The median pooled viral load was calculated accounting for between-study heterogeneity using a random effects model. Viral load values were log-transformed because of the non-normal distribution of the data. Patients with 2 consecutive viral loads 3 months apart above 1,000 copies/ml with adherence counseling after the first viral load are to be considered failing their ART regimen [18]. The performance (sensitivity, specificity, and clinical misclassification) of dried blood spot specimens compared with plasma on each platform was assessed. Since longitudinal data on dried blood spot specimen performance were not available, cross-sectional comparisons were performed. In addition, alternate treatment failure thresholds for viral load using dried blood spot specimens were assessed including 1,000, 3,000, 5,000, 7,500, and 10,000 copies/ml to understand the threshold that best compares to the gold standard plasma specimens for each technology. Each treatment failure threshold of dried blood spot specimens was compared to 1,000 copies/ml for plasma with measurements of true positives, true negatives, false positives, and false negatives calculated for each technology to create pooled estimates of diagnostic accuracy of dried blood spot specimens for each platform across all studies. Using these treatment failure thresholds, the sensitivity, specificity, upward and downward misclassification rates, and positive and negative predictive values were also calculated. Misclassification was calculated as the proportion of dried blood spot specimens incorrectly identified as above or below 1,000 copies/ml compared to the plasma specimens. Upward misclassification was defined as the number of dried blood spot specimens incorrectly identified as above the tested treatment failure threshold divided by the total number of matched plasma specimens with viral load results below 1,000 copies/ml. Downward misclassification was defined as the number of dried blood spot specimens incorrectly identified as below the tested treatment failure threshold divided by the total number of matched plasma specimens with viral load results above 1,000 copies/ml. Pooled estimates of accuracy and misclassification were calculated using a series of methods to first quantify and then account for the presence of study heterogeneity when calculating pooled estimates. To determine the presence of between-study heterogeneity, the Q-statistic was calculated for each treatment failure threshold comparison (for example, 1,000 copies/ml using dried blood spot specimens to 1,000 copies/ml using plasma specimens; 3,000 copies/ml using dried blood spot specimens to 1,000 copies/ml using plasma specimens, etc.) [73]. After confirming the presence of heterogeneity, random effects models were used to estimate the pooled summary measures for bias, accuracy, and fit hierarchical summary receiver-operator curves (HSROCs) accounting for between-study variation. For sensitivity and specificity values and corresponding 95% confidence intervals, bivariate random effects modeling was used to simultaneously determine the pooled estimates, accounting for the covariance of sensitivity and specificity as well as study specific heterogeneity [74]. Univariate random effects models were used when less than 4 studies were included in the model methods, as bivariate random effects models were unstable. To obtain pooled estimates of misclassification, univariate random effects models were used to obtain the point estimates and corresponding 95% confidence intervals [75]. All statistics were calculated overall, for each technology, and for each study data set. We included a continuity correction to all of the diagnostic values of a study if at least 1 diagnostic value had a zero value. Bland–Altman plots were created to assess mean bias values. In these plots, the mean viral load value was assessed by dried blood spot specimens and plasma (x axis) compared to the mean difference between paired dried blood spot specimens and plasma specimens (y axis) to evaluate the degree of agreement between the 2 methods. Several sub-analyses were conducted to further examine the diagnostic accuracy and clinical misclassification of dried blood spot specimens by specific populations or technologies. First, the diagnostic accuracy statistics were calculated for the comparison of 1,000 copies/ml using dried blood spot specimens to 1,000 copies/ml using plasma specimens limiting the analysis to studies that included only patients on antiretroviral therapy. Second, the diagnostic accuracy statistics were measured stratifying those studies that processed dried blood spot specimens and performed viral load testing according to the manufacturer’s recommended protocol and those that did not. Additionally, sub-analyses were analyzed by specimen collection method (capillary versus venous blood collection), specimen storage method (fresh versus frozen), geography, and dried blood spot card type. Finally, in a third sub-analysis only data from the most recent version of the specified technologies were included. Three researchers independently performed the statistical analysis to ensure accuracy. Graphic representations were completed in GraphPad Prism (La Jolla, California, USA) and analyses were completed in Stata 13 (College Station, Texas, USA) and SAS version 9.2 (Cary, North Carolina, USA).

Protocol

The prepared protocol was reviewed by the World Health Organization and approved by Chesapeake Institutional Research Review Board (Columbia, Maryland, USA; www.chesapeakeirb.com) (S1 Text).

Results

Systematic review

A total of 60 studies were identified for inclusion (Fig 1 and Table 1) [19-69]. Thirteen studies were excluded due to using a qualitative assay, 8 studies were drug resistance testing studies, 2 studies used panels as primary sample types, 2 studies were review manuscripts lacking primary data, 2 studies used spike blood samples, and 1 study used an incorrect comparator. There was low to moderate heterogeneity in the analytical and clinical performance comparisons within technologies as well as in the viral load medians and distributions (Table 2).
Table 1

Study characteristics and dried blood spot specimen preparation process.

First authorReferenceManuscript dateTechnologyDBS paper typevDBS blood type/volumeDBS drying timeNumber spots usedDBS storageDBS prep: buffer/mix timeSample/NAT isolationLocationSample sizeVenous or finger-prickAll patients on ART?
Abravaya[19]2008Abbott m2000rt RealTime HIV-1Whatman 90350 ulUnknown2Unknown1.7 ml Abbott lysis buffer/2 hAbbott m2000spUnknownNRVenousUnknown
Arredondo[23]March 2011Abbott m2000rt RealTime HIV-1Whatman 90350 ul4–6 h at RT2Bag with silica -20C2 ml Abbott lysis buffer/2 hAbbott m2000spSpain157Venous30%
Carmona[26]UnknownAbbott m2000rt RealTime HIV-1Munktell TFN70 ul EDTAO/N at RT2Bag at RT1.7 ml Abbott lysis buffer/30 minAbbott m2000spSouth Africa113VenousUnknown
David[27]June 2012Abbott m2000rt RealTime HIV-1Whatman 90350 ul EDTA6–8 h at RT2Bag with desiccant -20C1.7 ml Abbott lysis buffer/2 hAbbott m2000spIndia62VenousUnknown
Erba[28]Dec 2015Abbott m2000rt RealTime HIV-1Unknown50 ul EDTAO/N at RT2Bag with desiccant at RT1.7 ml Abbott lysis buffer/15 minAbbott m2000spMalawi and Mozambique277VenousUnknown
Garrido[31]Nov 2008Abbott m2000rt RealTime HIV-1Whatman 90350 ul EDTAO/N at RT14C until processed2 ml NucliSens lysis buffer/2 hAbbott m2000spSpain81VenousUnknown
Lofgren[37]Nov 2009Abbott m2000rt RealTime HIV-1Whatman 90350 ul EDTA>4 h RT2Bag with desiccant1.7 ml Abbott lysis buffer/2 hAbbott m2000spTanzania313Venous53%
Marconi[38]June 2008Abbott m2000rt RealTime HIV-1Whatman 90350 ul1–170 days at RT2Unknown2 ml Abbott lysis buffer/ 2 hAbbott m2000spItaly163VenousUnknown
Mbida[39]Dec 2008Abbott m2000rt RealTime HIV-1Whatman 90350 ulO/N at RT2Bag at RT1.7 ml Abbott lysis buffer/2 hAbbott m2000spCameroon; DBS France45Venous12 of 27
Monleau[42]Dec 2013Abbott m2000rt RealTime HIV-1Whatman 90350 ul EDTA3 h at RT2Silica 2–4 weeks RT, -20C1.7 ml Abbott lysis buffer/30 minAfrica, Asia173VenousYes, >24 m
MwauUnknownAbbott m2000rt RealTime HIV-1UnknownKenya216Venous
Neogi[45]Nov 2011Abbott m2000rt RealTime HIV-1Whatman 90350 ul EDTAO/N at RT2Bag with silica RT1.7 ml Abbott lysis buffer/2 hAbbott m2000spIndia125Venous71 of 125
Rutstein[54]May 2014Abbott m2000rt RealTime HIV-1Munktell TFN50 ul3 h at RT2Bag with desiccant at RT1.7 ml Abbott lysis buffer/30 minAbbott m2000spMalawi547VenousYes
Schmitz[57]April 2017Abbott m2000rt RealTime HIV-1Whatman 90350 ul EDTAO/N at RT2Bag with desiccant at RTAbbott lysis bufferAbbott m2000spKenya416BothMost
Taieb[58]2018Abbott m2000rt RealTime HIV-1Munktell TFN70 ul EDTA3 h at RT1Bag with desiccant -20C1.3 ml Abbott lysis buffer/30 minAbbott m2000spVietnam401Venous76%
Tang[59]2017Abbott m2000rt RealTime HIV-1Munktell TFN70 ulUnknown1RT or -20C1.3 ml Abbott lysis buffer/30 minAbbott m2000spCote d’Ivoire, Uganda, South Africa497Both49%
Vidya[63]Oct 2011Abbott m2000rt RealTime HIV-1Whatman 90350 ulO/N at RT2Bag with silica RT1.7 ml Abbott lysis buffer/2 hAbbott m2000spIndia100VenousUnknown
Zeh[69]2017Abbott m2000rt RealTime HIV-1Whatman 90350 ulO/N at RT2Bag at 2-8C1.7 ml Abbott lysis buffer/30 minAbbott m2000spKenya200VenousYes
MonleauJan 2010Biocentric G2 GenericWhatman 90350 ul3 h at RT4Bag with silica -20C4 ml NucliSens lysis buffer/2 hNucliSens miniMAGFrance34VenousUnknown
Monleau[42]Dec 2013Biocentric G2 GenericWhatman 90350 ul EDTA3 h at RT2Silica 2–4 weeks RT, -20C2 ml NucliSens lysis buffer/30 minNucliSens miniMAGAfrica, Asia118VenousYes, >24 m
Reigadas[52]Feb 2009BiocentricWhatman 90350 ul EDTA1 h at RT5Bag with desiccant at 4C220 ul lysis buffer/1 h, QIAampQIAampFrance86Venous17
Viljoen[64]Jan 2010BiocentricWhatman 90350 ul EDTAO/N at RT1 or 2Bag with silica -20C1: 9 ml NucliSens/1 h 2: 2ml NucliSens/1 hNucliSens miniMAGSouth Africa, Burkina Faso327VenousSome
Yapo[67]July 2013BiocentricWhatman 903UnknownUnknown3-80C180 ul buffer/1 hQIAampCote d’Ivoire138VenousNone
Alvarez-Munoz[21]Sep 2004bioMerieux NucliSens HIV-1 QTWhatman 90350 ul EDTAO/N at RT2Bag with silica RT9 ml NucliSens lysis buffer/2 hNucliSens extractionMexico124VenousUnknown
Ayele[24]Sep 2006bioMerieux NucliSens HIV-1 QTWhatman 90350 ul EDTAUnknown4Bag with desiccant at RT3 ml lysis buffer/2 h or O/NNucliSens extraction/Boom methodEthiopia19VenousUnknown
Brambilla[25]July 2002bioMerieux NucliSens HIV-1 QTWhatman 90350 ulO/N at RTUnknownBag with silica -20C9 ml NucliSens lysis buffer/2 hNucliSens extraction/Boom methodUnknown76VenousUnknown
Fajardo[29]Feb 2014bioMerieux NucliSens EasyQ HIV-1 v2.0Whatman 90350 ulO/N at RT2Bag with desiccant at RT2 ml NucliSens lysis buffer/30 minNucliSens easyMAGMalawi770VenousSome
Fiscus[30]May 1997bioMerieux NucliSens HIV-1 QTWhatman 90350 ul/100 ul EDTAO/N at RT2 of 50 ul eachRT until processed9 ml NucliSens lysis buffer/2 hNucliSens extractionUSA76VenousUnknown
Garrido[31]Nov 2008bioMerieux NucliSens EasyQ HIV-1 v1.1Whatman 90350 ul EDTAO/N at RT14C until processed2 ml NucliSens lysis buffer/2 hNucliSens extraction/Boom methodSpain97VenousUnknown
Johannessen[33]Jan 2009bioMerieux NucliSens EasyQ HIV-1 v1.2Whatman 903PPT:DBS, plasmaO/N at RT2Bag with silica -20C9 ml NucliSens lysis buffer/2 hNucliSens extraction/Boom methodTanzania98VenousYes, >6 months
Lira[36]Nov 2009bioMerieux NucliSens HIV-1 QTWhatman 90350 ul EDTA4 h at RT2Bag with silica -70C9 ml NucliSens lysis buffer/2 hNucliSens extractionMexico57Venous84.50%
Mercier-Delarue[40]Oct 2013bioMerieux NucliSens EasyQ HIV-1 v2.0Whatman 90350 ul EDTART2Bag at RT2 ml NucliSens lysis buffer/2 hNucliSens easyMAGNiger192VenousSome
Monleau[42]Dec 2013bioMerieux NucliSens EasyQ HIV-1 v1.2Whatman 90350 ul EDTA3 h at RT2Silica 2–4 weeks RT, -20C2 ml NucliSens lysis buffer/30 minNucliSens miniMAGAfrica, Asia91VenousYes, >24 m
Mwaba[44]Dec 2003bioMerieux NucliSens HIV-1 QT?Whatman 90350 ul3 h at RTUnknownBag with silica RT9 ml NucliSens lysis buffer/2 hNucliSens extraction/Boom methodZambia; DBS Canada51VenousNone
Rottinghaus[53]Oct 2011bioMerieux NucliSens EasyQ HIV-1 v1.1Whatman 903100 ul EDTAO/N at RT1Bag with desiccant at RT2 ml NucliSens lysis buffer/30 minNucliSens easyMAGNigeria; DBS Atlanta173VenousYes
Toure Kane[34]Apr 2007bioMerieux NucliSens EasyQ HIV-1 v1.2Whatman 90350 ul EDTAO/N at RT2Bag with silica RT2 ml Abbott lysis buffer/30 minNucliSens miniMAG/Boom methodFrance, Senegal41VenousUnknown
Uttayamakul[61]Jan 2005bioMerieux NucliSens HIV-1 QTWhatman 90350 ul EDTAO/N at RT1Bag with desiccant -20C1 ml lysis buffer/30 minNucliSens extraction/Boom methodThailand209VenousNo
van Deursen[62]July 2009bioMerieux NucliSens EasyQ HIV-1 v2.0Whatman 90350 ul EDTA3 h—O/N at RT2Bag with desiccant at RT2 ml Abbott lysis buffer/30 minNucliSens easyMAGNetherlands and France218VenousYes
GousOct 2016Hologic Aptima HIV-1 Quant DxWhatman 90370 ul EDTAO/N at RT1Bag with desiccant -70C1 ml Hologic buffer for 30 at RTIntegrated into Aptima PantherSouth Africa20VenousSome
Sahoo[55]Aug 2016Hologic Aptima HIV-1 Quant DxWhatman 90350 ul EDTAUnknown1-80C1 ml Hologic buffer for 30 at RTIntegrated into Aptima PantherUSA162VenousUnknown
Yek[68]Aug 2017Hologic Aptima HIV-1 Quant DxWhatman 90350 ul EDTAO/N at RT1Bag with desiccant at RT or -20C1 ml Hologic buffer for 30 at RTIntegrated into Aptima PantherUSA104VenousSome
Aitken[20]Jan 2013Roche COBAS Ampliprep/TaqMan v2Unknown50 ul EDTAUnknown2Varied700 ul elution buffer, QIAampRoche COBAS AmpliprepUganda409VenousUnknown
Andreotti[22]Aug 2009Roche COBAS TaqMan RT-PCRWhatman 90375 ul EDTA4 h at RT1Bag with desiccant -20C2 ml NucliSens lysis buffer/O/NNucliSens miniMAG/Boom methodMalawi; DBS Italy129Venous18
Brambilla[25]July 2002Roche Amplicor Monitor v1.5Whatman 90350 ulO/N at RTUnknownBag with silica -20C0.75 ml CORD solution/30 minMonitor specimen diluentUnknown3VenousUnknown
Carmona[26]2011Roche COBAS Ampliprep/TaqMan v2Munktell TFN70 ul EDTA3 h at RT1Bag at RT1 ml SPEX/10 min at 56CRoche COBAS AmpliprepSouth Africa107VenousUnknown
CarmonaUnknownRoche COBAS Ampliprep/TaqMan v2Munktell TFN70 ul EDTAO/N at RT1Bag at RT1 ml PBS/1 h at RTRoche COBAS AmpliprepSouth Africa281VenousUnknown
Ikomey[32]UnknownRoche Amplicor Monitor v1.5Whatman 90350 ul EDTA2 h—O/N at RT4Bag900 ul lysis buffer/cen 20 mRocheCameroon60VenousUnknown
Leelawiwat[35]July 2008Roche Amplicor Monitor v1.5Whatman 903≈50 ul heel-prick24–48 h at RT1Bag with desiccant0.9 ml NucliSens lysis buffer/2 hNucliSens extractionThailand56VenousMono or dual therapy
Mercier-Delarue[40]Oct 2013Roche COBAS Ampliprep/TaqMan v2Whatman 90350 ul EDTART2Bag at RT2 ml NucliSens lysis buffer/2 hRoche COBAS AmpliprepNiger197VenousSome
Onkendi[47]2017Roche COBAS Ampliprep/TaqMan v2Whatman 90370 ul EDTA4 h at RT1Bag with desiccant1 ml PBS/1 h at RTRoche COBAS AmpliprepKenya180VenousSome
Ouma[48]Nov 2012Roche COBAS Amplicor v1.5/TaqMan v2Whatman 90375 ul EDTAO/N at RT1Bag with desiccant -20C600 ul Qiagen elution buffer/15 min at 56CRoche COBAS AmpliprepKenya432VenousNo
Pannus[49]2016Roche COBAS Ampliprep/TaqMan v2Whatman 90370 ul EDTAO/N at RT1Bag with desiccant -20C1 ml PBS/1 h at RTRoche COBAS AmpliprepBelgium261VenousUnknown
Pollack[51]2018Roche COBAS Ampliprep/TaqMan v2Whatman 90370 ul4 h at RT1Bag with desiccant -4C1 ml SPEX/10 min at 56C and 1 ml PBS/1 h at RTRoche COBAS AmpliprepVietnam876VenousSome
Sawadogo[56]Aug 2014Roche COBAS Amplicor v1.5/TaqMan v2Whatman 90350 ul EDTAUnknown1Bag with desiccant -70C1.1 ml SPEX/10minRoche COBAS AmpliprepNamibia823VenousYes, >6 months
Tariro Makadzange[60]May 2017Roche COBAS Ampliprep/TaqMan v2Whatman 90350 ulO/N at RT1Bag with dessicant at RT1 ml PBS/1 h at RTRoche COBAS AmpliprepZimbabwe272VenousUnknown
Waters[65]Feb 2007Roche COBAS TaqMan RT-PCRWhatman 903Not indicatedRTUnknownBag at RTUnknownPrimagenUganda; DBS Europe307VenousYes
Wu[66]UnknownRoche COBAS Ampliprep/TaqMan v2Whatman 90370 ulUnknown1Unknown1 ml PBS/30 minRoche COBAS AmpliprepUSA196VenousUnknown
ZehUnknownRoche COBAS Ampliprep/TaqMan v2Whatman 90350 ulO/N at RT1Bag at 2–8C1.1 ml SPEX/10 minRoche COBAS AmpliprepKenya200VenousYes
ZehUnknownRoche COBAS Ampliprep/TaqMan v2Whatman 90350 ulO/N at RT1Bag at 2–8C1.1 ml PBS/30 minRoche COBAS AmpliprepKenya171VenousYes
ZhangUnknownRoche COBAS Ampliprep/TaqMan v2Whatman 90370 ul EDTAO/N at RT1Bag at RT1 ml PBS/1 h at RTRoche COBAS AmpliprepCote d’Ivoire1093VenousYes
Zinyowera[43]2013Roche COBAS TaqMan RT-PCRMunktell TFN70 ul finger-prick3 h at RT1Unknown1 ml SPEX/10 min at 56CRoche COBAS AmpliprepZimbabwe119Finger-prickYes
Pirollo[50]May 2011Siemens VERSANT HIV-1 RNA 1.0 (kPCR)Whatman 90350 ul EDTART1Bag with desiccant at RT1.25 Siemens lysis bufferVERSANT Sample Preparation ModuleItaly98VenousUnknown
SiemensSiemens VERSANT HIV-1 RNA 1.0 (kPCR)Unknown46Venous
Table 2

Analytical and clinical metrics for each study.

ReferenceR2bias (95% CI)Median plasmaMedian DBSDifference in mediansProportion undetectableProportion 1–10,000 cp/mlProportion > 10,000 cp/ml
AbravayaAbbott m2000rt RealTime HIV-1[19]Quantitative data not reported
AitkenRoche COBAS Ampliprep/TaqMan v2[20]NR
Alvarez-MunozbioMerieux NucliSens HIV-1 QT[21]0.9025NR
AndreottiRoche COBAS TaqMan RT-PCR[22]0.8328−0.474 (−1.98–1.03)4.073.760.3114.7%34.1%51.2%
ArredondoAbbott m2000rt RealTime HIV-1[23]0.82810.13 (−1.00–1.25)0.35
AyelebioMerieux NucliSens HIV-1 QT[24]0.5524−0.794 (2.90–1.31)4.643.900.740.0%31.6%68.4%
BrambillabioMerieux NucliSens HIV-1 QT[25]Three patients included, viral loads >3.5 log copies/ml
CarmonaAbbott m2000rt RealTime HIV-1[26]0.5877−0.218 (−2.95–2.51)3.763.150.6126.6%27.4%46.0%
Roche COBAS Ampliprep/TaqMan v2[26]0.74260.747 (−1.34–2.83)3.954.08−0.137.5%43.0%49.5%
Roche COBAS Ampliprep/TaqMan v2 FVE0.7951−0.096 (−1.81–1.62)3.253.27−0.0211.2%54.6%34.2%
DavidAbbott m2000rt RealTime HIV-1[27]0.94090.47 (−0.18–1.12)0.41
ErbaAbbott m2000rt RealTime HIV-1[28]0.78090.01 (−0.75–0.77)4.114.030.070.0%44.2%55.8%
Fajardo—capillarybioMerieux NucliSens EasyQ HIV-1 v2.0[29]0.658−0.35 (−1.26–0.56)
venousbioMerieux NucliSens EasyQ HIV-1 v2.0[29]0.689−0.22 (−1.13–0.69)
FiscusbioMerieux NucliSens HIV-1 QT[30]0.5988−0.424 (−3.30–2.46)4.484.200.2822.4%14.5%63.2%
GarridoAbbott m2000rt RealTime HIV-1[31]0.89540.147 (−0.39–0.68)3.814.15−0.3436.1%43.3%20.6%
bioMerieux NucliSens EasyQ HIV-1 v1.1[31]0.7585−0.577 (−2.59–1.43)3.040.003.0436.1%33.0%30.9%
GousHologic Aptima0.7874−0.134 (−1.30–1.03)4.043.970.0710.0%40.0%50.0%
JohannessenbioMerieux NucliSens EasyQ HIV-1 v1.2[33]0.6538−0.672 (−3.10–1.76)2.000.002.0033.7%45.9%20.4%
LirabioMerieux NucliSens HIV-1 QT[36]0.801−0.060 (−0.71–0.59)4.614.530.070.0%24.6%75.4%
LofgrenAbbott m2000rt RealTime HIV-1[37]0.9477−0.083 (−1.26–1.10)0.000.000.0052.7%15.0%32.3%
MarconiAbbott m2000rt RealTime HIV-1[38]0.7812−0.407 (−2.56–1.75)3.453.93−0.4815.2%40.8%44.0%
MbidaAbbott m2000rt RealTime HIV-1[39]0.8787−0.272 (−1.87–1.32)3.623.70−0.0820.0%35.6%44.4%
Mercier-DelaruebioMerieux NucliSens EasyQ HIV-1 v2.0[40]0.7602−0.544 (−2.54–1.45)2.772.560.2224.5%42.2%33.3%
Roche COBAS Ampliprep/TaqMan v2[40]0.51570.217 (−2.47–2.91)2.993.44−0.4418.8%40.6%40.6%
Monleau 2010Biocentric G2 Generic[41]NR0.45
Monleau 2013Abbott m2000rt RealTime HIV-1[42]0.47590.089 (−3.21–3.39)0.000.000.0059.3%19.0%21.7%
Biocentric G2 Generic[42]0.33860.926 (−2.38–4.24)2.583.11−0.5346.6%30.5%22.9%
bioMerieux NucliSens EasyQ HIV-1 v1.2[42]0.8000−0.476 (−1.89–0.93)3.763.360.4011.0%48.4%40.7%
MwauAbbott m2000rt RealTime HIV-10.6517−1.169 (−3.44–1.11)2.190.002.1943.2%37.0%19.8%
NeogiAbbott m2000rt RealTime HIV-1[45]0.7169−0.485 (−2.81–1.84)1.770.001.7739.3%38.7%22.0%
OnkendiRoche COBAS Ampliprep/TaqMan v2 FVE[47]0.917−0.200 (−0.63–0.23)
OumaRoche COBAS Amplicor v1.5/TaqMan v2[48]0.65750.206 (−0.88–1.30)4.334.54−0.211.2%32.4%66.4%
PannusRoche COBAS Ampliprep/TaqMan v2 FVE[49]0.74180.296 (−1.06–1.65)3.543.63−0.0110.7%59.1%39.9%
PirolloSiemens VERSANT HIV-1 RNA 1.0 (kPCR)[50]0.7697−0.318 (−2.06–1.42)3.573.250.3313.3%44.9%41.8%
PollackRoche COBAS Ampliprep/TaqMan v2 SPEX[51]0.37011.813 (−0.91–4.54)1.723.73−2.0134.5%50.4%15.1%
Roche COBAS Ampliprep/TaqMan v2 FVE[51]0.60830.382 (−1.58–2.34)3.063.30−0.2414.2%64.0%21.8%
ReigadasBiocentric[52]0.1312−0.536 (−4.83–3.76)4.103.990.1114.0%32.6%53.5%
RottinghausbioMerieux NucliSens EasyQ HIV-1 v1.1[53]0.75270.054 (−1.36–1.47)0.000.000.0085.0%7.5%7.5%
Rutstein—capillaryAbbott m2000rt RealTime HIV-1[54]0.81NR1.14
venousAbbott m2000rt RealTime HIV-1[54]0.8649NR1.14
SahooHologic Aptima[55]−0.075 (−0.62–0.48)
SawadogoRoche COBAS Amplicor v1.5/TaqMan v2[56]0.36511.715 (−1.20–4.63)1.513.76−2.2639.9%44.6%15.6%
SchmitzAbbott m2000rt RealTime HIV-1[57]0.07–0.09
SiemensSiemens VERSANT HIV-1 RNA 1.0 (kPCR)0.78300.002 (−1.24–1.24)3.633.68−0.050.0%67.4%32.6%
TaiebAbbott m2000rt RealTime HIV-1[58]0.84320.090 (−0.82–0.99)3.224.30−1.0858.6%25.3%16.2%
Abbott m2000rt RealTime HIV-1 one-spot[58]0.7631−0.001 (−0.08–0.08)0.610.62−0.0134.8%65.2%0.0%
Roche COBAS Ampliprep/TaqMan v2 FVE[58]0.6393−2.090 (−4.44–0.26)2.7802.7841.9%39.9%18.2%
TangAbbott m2000rt RealTime HIV-1 one-spot[59]0.91660.087 (−0.53–0.71)4.294.020.2765.0%12.3%22.7%
Tariro MakadzangeRoche COBAS Ampliprep/TaqMan v2 FVE[60]0.782−1.07 (−0.06–2.16)5.334.261.0758.1%
Toure KanebioMerieux NucliSens EasyQ HIV-1 v1.2[34]0.9334−0.108 (−1.02–0.80)3.763.600.1614.6%41.5%43.9%
UttayamakulbioMerieux NucliSens HIV-1 QT[61]0.6670.17
van DeursenbioMerieux NucliSens EasyQ HIV-1 v2.0[62]0.7750−0.544 (-2.24–1.15)1.910.001.9133.0%49.5%17.4%
VidyaAbbott m2000rt RealTime HIV-1[63]0.7069−0.141 (−1.61–1.32)4.374.39−0.020.0%39.0%61.0%
ViljoenBiocentric[64]0.59580.277 (−0.64–1.20)4.334.65−0.320.0%29.7%70.3%
WatersRoche COBAS TaqMan RT-PCR[65]0.84020.209 (−1.33–1.75)3.242.740.5081.3%9.7%9.0%
WuRoche COBAS Ampliprep/TaqMan v2 FVE[66]0.8003−1.055 (−3.07–0.96)3.240.003.2481.3%9.7%9.0%
YapoBiocentric[67]0.920.65 (−1.35–0.06)0.77
YekHologic Aptima[68]0.74180.075 (−1.56–1.71)3.343.49−0.1559.6%26.9%13.5%
ZehAbbott m2000rt RealTime HIV-1[69]0.88400.264 (−1.33–1.86)3.684.45−0.7723.0%34.5%42.5%
Roche COBAS Ampliprep/TaqMan v2[69]0.63681.002 (−1.80–3.81)4.014.36−0.3525.0%25.0%50.0%
Roche COBAS Ampliprep/TaqMan v2 FVE0.6210−0.364 (−2.44–1.71)0.000.000.0063.2%28.1%8.8%
ZhangRoche COBAS Ampliprep/TaqMan v2 FVE0.8615−0.058 (−1.67–1.56)1.400.001.4048.3%22.5%29.2%
ZinyoweraRoche COBAS TaqMan RT-PCR[43]0.30800.573 (−2.01–3.51)0.000.000.0089.9%5.5%4.6%

NR: not reported.

Gray shading: studies included in the meta-analysis.

NR: not reported. Gray shading: studies included in the meta-analysis.

Quality of studies

There was some risk of bias in patient selection, however, low risk of bias with the reference standard and index test (S2 Fig). Participants in most studies were not consecutively recruited or failed to report the process of patient recruitment and only 5% of studies reported the process of patient recruitment. There was a high applicability in patient selection, index test, and reference standard; however, there were some concerns as most studies (58%) were carried out in Africa; most studies (>90%) used venous blood prepared in the laboratory with a pipet; and most studies (>90%) used only 1 dried blood spot filter paper (Whatman 903).

Systematic review analysis

Mean bias was the most commonly reported analytical measurement across all studies included in the systematic review (82%); therefore, forest plots of each study were developed by technology (S3 Fig). Half of the studies included patients on antiretroviral therapy [21-23,29,33,35-37,39,40,42,43,45-47,51-54,56-59,62,64,65,68,69], whereas the remaining studies either included patients not on antiretroviral therapy or did not indicate such information. The study characteristics such as sample size, viral load medians, and patient viral load distributions are summarized in Table 2.

Meta-analysis

A total of 40 studies provided 45 data sets across the 6 technologies resulting in a total of 10,871 paired dried blood spot and plasma viral load results [22,24,26,28,30,31,33,34,36-45,48-53,56,58,59,62-66,68,69]. Those studies not included from the systematic review were due to primary authors’ inability to sharing data. Of these 58% of pairs were analyzed with the Roche COBAS TaqMan technology [22,26,40,43,48,49,51,56,58,65,66,69], 25% with the Abbott RealTime HIV-1 technology [26,28,31,37-39,42,45,58,59,63,69], 10% with the bioMérieux NucliSENS EasyQ technology [24,30,31,33,34,36,40,42,53,62], 5% with the Biocentric Generic HIV Charge Virale technology [41,52,64], 1% with the Hologic Aptima [68], and 1% with the Siemens VERSANT HIV-1 RNA technology [50]. Approximately 70% of the paired data points were from studies conducted in Africa [22,24,26,28,33,34,37,39,40,42,43,48,53,56,58,59,64,65,74], of which 36% were from the Southern African Development Community region [22,26,28,42,43,56,59,64] and 24% from the East African Community region [24,33,37,48,65,69]. The viral load distribution for the 10,871 plasma specimens tested was relatively equally distributed across all viral load ranges (Fig 2A). While approximately 41% of all plasma specimens were undetectable (below the technology’s limit of detection), 30% of all plasma study specimens were between detectable (at or greater than the technology’s limit of detection) and 10,000 copies/ml. Furthermore, when including only plasma specimens from patients known to be on ART, we observed that just over 40% of patients had undetectable levels of viral load (Fig 2B). Approximately 31% of plasma specimens from patients on ART were between detectable and 10,000 copies/ml.
Fig 2

Patient plasma viral load distribution from all studies (a) and including only patients on antiretroviral therapy (b).

Patient plasma viral load distribution from all studies (a) and including only patients on antiretroviral therapy (b). The median dried blood spot viral loads were higher than the median plasma viral loads for all but 2 technologies. Overall, the median difference was 1.03 log copies/ml (Table 3). The Abbott RealTime HIV-1 two-spot, Abbott RealTime HIV-1 one-spot, Biocentric Generic HIV Charge Virale, bioMérieux NucliSENS EasyQ HIV-1, Hologic Aptima, Roche COBAS TaqMan FVE, Roche COBAS TaqMan SPEX, and Siemens VERSANT HIV-1 RNA technologies had a difference between the median dried blood spot and plasma specimen viral loads of 0.09, 0.04, 0.17, −0.30, 0.12, 0.33, 1.99, and −0.13 log copies/ml, respectively. The mean bias for each technology was calculated by pooling all primary data for each technology as though one study (Table 3). The mean biases between the dried blood spot and plasma viral load values varied significantly depending on the technology. The overall mean bias was 0.30 log copies/ml. The Abbott RealTime HIV-1 two-spot (−0.12 log copies/ml), Abbott RealTime HIV-1 one-spot (0.02 log copies/ml), and Roche COBAS TaqMan FVE (0.06 log copies/ml) assay biases were closest to zero, while the bioMerieux NucliSENS EasyQ HIV-1 (−0.41 log copies/ml) and Roche COBAS TaqMan SPEX (1.03 log copies/ml) assay biases were furthest from zero. The Abbott RealTime HIV-1 two-spot, bioMerieux NucliSENS EasyQ HIV-1, and Siemens VERSANT HIV-1 RNA technologies had negative mean biases indicating under-quantification compared to the plasma viral load result, which is expected due to the lower input sample volume. The positive mean biases of Biocentric Generic HIV Charge Virale and Roche COBAS TaqMan SPEX reflect over-quantification compared to the plasma viral load result, likely due to processing and extraction chemistries resulting in amplification of total intracellular and extracellular nucleic acids.
Table 3

Meta-analysis of clinical metrics overall and for each viral load technology.

All technologiesAbbott RealTime HIV-1 two-spotAbbott RealTime HIV-1 one-spotBiocentric Generic HIV Charge ViralebioMerieux NucliSENS EasyQ HIV-1Hologic AptimaRoche COBAS TaqMan HIV-1 FVERoche COBAS TaqMan HIV-1 SPEXSiemens VERSANT HIV-1 RNA
n10,8312,0047005311,0621243,0763,190144
Dried blood spot
Median viral load (log copies/ml)3.043.340.684.342.363.651.653.483.46
Plasma
Median viral load (log copies/ml)2.013.250.644.172.663.531.321.493.59
Difference in medians (log copies/ml)1.030.090.040.17−0.300.120.331.99−0.13
Mean bias (log copies/ml)0.30−0.120.020.29−0.410.040.061.03−0.22
DBS:plasma threshold comparisons
Sensitivity (UCL-LCL) 1,000:1,00093.33 (89.85–95.68)93.13 (83.72–97.27)88.26 (49.64–98.28)94.86 (71.14–99.28)82.95 (78.38–86.71)84.61 (43.55–97.51)94.77 (84.59–98.36)98.23 (95.85–99.26)90.97 (69.20–97.83)
3,000:1,00084.41 (79.07–88.59)85.41 (69.54–93.75)83.00 (72.34–90.11)91.29 (64.11–98.40)73.93 (64.92–81.29)71.32 (51.01–85.58)81.65 (73.29–87.83)93.32 (88.38–96.25)74.71 (65.03–82.44)
5,000:1,00076.84 (72.36–80.80)79.13 (60.68–90.31)81.60 (70.79–89.03)80.19 (51.31–93.96)64.54 (55.34–72.78)62.45 (45.82–76.58)73.63 (66.69–79.56)88.32 (81.47–92.85)68.30 (58.27–76.88)
7,500:1,00069.89 (64.96–74.40)70.30 (52.22–83.68)76.01 (64.72–84.55)74.36 (46.21–90.73)55.96 (46.24–65.25)54.15 (37.98–69.49)67.13 (58.14–75.01)78.66 (69.74–85.49)62.56 (50.11–73.53)
10,000:1,00062.38 (56.42–67.99)64.52 (46.58–79.13)71.81 (60.28–81.04)66.26 (38.27–86.15)52.76 (42.82–62.48)51.35 (35.37–67.06)61.22 (51.90–69.78)72.15 (63.05–79.74)54.74 (44.67–64.43)
Specificity (UCL-LCL) 1,000:1,00086.76 (77.83–92.44)91.11 (82.35–95.75)99.07 (68.38–99.98)55.16 (35.01–73.75)95.06 (89.29–97.80)73.44 (31.27–94.38)93.93 (71.95–98.94)48.49 (22.63–75.18)87.76 (75.28–94.41)
3,000:1,00095.47 (92.18–97.42)96.29 (92.16–98.28)99.81 (98.64–99.97)71.56 (31.04–93.36)97.16 (91.06–99.14)90.49 (53.53–98.74)98.47 (95.47–99.49)81.68 (54.59–94.29)97.95 (86.81–99.71)
5,000:1,00096.95 (94.60–98.29)97.15 (94.35–98.59)99.81 (98.64–99.97)89.43 (59.20–98.01)97.45 (92.16–99.20)94.92 (27.42–99.89)99.12 (98.02–99.61)91.37 (75.19–97.37)97.95 (86.81–99.71)
7,500:1,00097.79 (96.17–98.74)97.80 (95.61–98.91)99.81 (98.64–99.97)92.17 (65.70–98.64)97.57 (93.93–99.05)96.71 (57.66–99.84)99.39 (98.58–99.74)93.14 (84.52–97.13)97.95 (86.81–99.71)
10,000:1,00098.17 (97.08–98.86)97.96 (95.87–99.00)99.81 (98.64–99.97)92.17 (65.70–98.64)98.18 (94.90–99.37)96.71 (57.66–99.84)99.60 (99.18–99.81)96.92 (90.37–99.06)97.95 (86.81–99.71)
Total misclassification (UCL-LCL) 1,000:1,00010.69 (7.79–14.50)8.50 (5.23–13.52)1.27 (0.04–27.05)13.71 (3.55–40.67)9.92 (7.58–12.88)NS8.85 (3.85–19.04)21.16 (11.45–35.78)9.34 (2.93–26.06)
3,000:1,00010.30 (7.65–13.73)9.27 (5.51–15.17)1.26 (0.04–26.75)9.57 (2.46–30.74)14.05 (9.94–19.51)NS7.12 (3.98–12.39)13.67 (6.05–28.01)16.89 (11.68–23.81)
5,000:1,00012.47 (9.87–15.64)11.72 (7.32–18.26)1.31 (0.04–29.26)14.03 (5.66–30.71)18.74 (13.10–26.09)NS8.94 (5.29–14.71)11.95 (6.03–22.30)20.99 (15.16–28.30)
7,500:1,00014.97 (12.30–18.10)14.51 (9.41–21.71)1.50 (0.04–38.69)16.74 (8.28–30.94)22.78 (16.46–30.62)NS10.62 (6.26–17.47)13.25 (8.01–21.14)25.12 (18.77–32.76)
10,000:1,00016.98 (14.13–20.27)16.99 (11.22–24.91)1.63 (0.03–45.03)21.43 (12.95–33.33)24.79 (18.12–32.93)NS12.35 (7.28–20.18)13.82 (8.93–20.77)29.74 (22.93–37.59)
Upward misclassification (UCL-LCL) 1,000:1,00014.21 (9.09–21.54)9.65 (5.00–17.81)0.93 (0.02–31.62)44.84 (26.25–64.99)4.94 (2.20–10.71)NS7.63 (1.40–32.52)51.00 (28.06–73.53)12.24 (5.59–24.72)
3,000:1,0004.78 (2.68–8.38)4.24 (2.05–8.54)0.19 (0.03–1.36)28.44 (6.64–68.96)2.34 (0.83–6.40)NS1.58 (0.45–5.42)19.63 (7.07–43.97)2.05 (0.29–13.19)
5,000:1,0003.05 (1.71–5.40)3.39 (1.67–6.78)0.19 (0.03–1.36)10.57 (1.99–40.80)2.34 (0.83–6.40)NS0.95 (0.36–2.51)10.08 (3.67–24.81)2.05 (0.29–13.19)
7,500:1,0002.21 (1.26–3.83)2.06 (0.87–4.81)0.19 (0.03–1.36)7.83 (1.36–34.30)2.11 (0.73–5.93)NS0.61 (0.26–1.42)6.86 (2.87–15.48)2.05 (0.29–13.19)
10,000:1,0001.77 (1.03–3.02)1.54 (0.57–4.13)0.19 (0.03–1.36)7.83 (1.36–34.30)1.82 (0.63–5.10)NS0.42 (0.20–0.89)5.06 (2.24–11.01)2.05 (0.29–13.19)
Downward misclassification (UCL-LCL) 1,000:1,0007.99 (5.75–11.02)7.42 (3.18–16.39)11.74 (1.72–50.36)5.14 (0.72–28.86)17.05 (13.29–21.62)NS6.73 (2.49–16.97)2.41 (1.09–5.24)9.03 (2.17–30.80)
3,000:1,00016.37 (13.14–20.20)15.38 (9.20–24.59)17.00 (9.89–27.66)8.71 (1.60–35.89)27.05 (20.54–34.71)NS18.67 (12.64–26.71)7.77 (4.39–13.40)25.29 (17.56–34.97)
5,000:1,00023.16 (19.20–27.64)21.59 (14.35–31.15)18.40 (10.97-–29.21)19.81 (6.04–48.69)34.87 (26.53–44.26)NS26.41 (20.02–33.97)12.38 (7.65–19.42)31.70 (23.12–41.73)
7,500:1,00030.11 (25.60–35.04)25.54 (17.72–35.32)23.99 (15.45–35.28)25.64 (9.27–53.79)43.19 (33.84–53.05)NS32.87 (24.99–41.86)21.34 (14.51–30.26)37.44 (26.47–49.89)
10,000:1,00035.94 (31.21–40.97)31.05 (21.83–42.06)28.19 (19.00–39.72)33.74 (13.85–61.73)47.24 (37.52–57.18)NS38.64 (29.55–48.60)27.75 (20.32–36.65)45.26 (35.57–55.33)
PPV (UCL-LCL) 1,000:1,00088.20 (82.69–92.13)91.77 (87.02–94.89)87.81 (65.23–96.51)86.46 (43.48–98.15)94.78 (91.15–96.97)NS86.68 (74.19–93.64)66.02 (44.99–82.19)92.71 (84.68–96.69)
3,000:1,00094.86 (91.34–97.00)96.18 (92.16–98.18)93.02 (11.31–99.93)92.81 (73.64–98.35)98.22 (96.09–99.20)NS95.53 (90.69–97.91)81.92 (62.50–92.49)98.54 (90.37–99.80)
5,000:1,00096.26 (93.31–97.94)97.01 (92.97–98.76)92.97 (11.40–99.93)96.23 (79.34–99.41)97.96 (95.53–99.08)NS97.38 (94.35–98.80)88.96 (72.06–96.18)98.43 (89.66–99.78)
7,500:1,00096.93 (94.35–98.35)97.61 (93.05–99.21)92.75 (11.80–99.92)97.88 (82.73–99.78)97.90 (95.24–99.09)NS98.25 (96.44–99.15)91.74 (76.61–97.41)98.29 (88.82–99.76)
10,000:1,00097.35 (95.08–98.59)97.95 (92.77–99.44)92.57 (12.12–99.91)97.63 (81.07–99.75)97.89 (95.03–99.12)NS98.66 (97.21–99.36)94.99 (82.96–98.66)98.01 (87.17–99.72)
NPV (UCL-LCL) 1,000:1,00091.79 (88.17–94.38)91.11 (81.40–96.00)99.20 (77.93–99.98)74.78 (23.33–96.65)80.93 (69.79–88.62)NS96.24 (91.92–98.30)96.79 (91.90–98.77)83.30 (59.76–94.37)
3,000:1,00085.46 (80.63–89.25)85.29 (72.82–92.62)98.86 (53.30–99.98)69.19 (31.21–91.75)72.55 (58.77–83.05)NS91.14 (83.57–95.42)92.20 (80.70–97.10)68.42 (57.18–77.85)
5,000:1,00080.91 (75.04–85.67)80.73 (67.37–89.47)98.82 (50.27–99.99)53.99 (18.12–86.15)66.22 (50.60–78.96)NS88.23 (78.92–93.75)89.19 (73.55–96.07)63.41 (52.51–73.09)
7,500:1,00076.31 (69.79–81.79)75.81 (62.41–85.54)98.66 (40.31–99.99)48.35 (13.64–84.72)62.08 (46.78–75.30)NS85.94 (75.22–92.49)83.43 (63.97–93.46)59.08 (48.55–68.83)
10,000:1,00073.29 (66.31–79.27)72.52 (58.99–82.88)98.55 (34.63–99.99)41.72 (10.32–81.66)60.29 (45.17–73.68)NS83.96 (72.18–91.35)80.38 (58.61–92.22)54.73 (44.66–64.43)

NS: insufficient data to perform meta-analysis.

NS: insufficient data to perform meta-analysis. WHO and many national clinical guidelines in resource-limited settings recommend using viral load testing as a binary result, above or below a specific threshold to identify treatment failure. We, therefore, compared several treatment failure thresholds for dried blood spot specimens (1,000, 3,000, 5,000, 7,500, and 10,000 copies/ml) to the currently suggested 1,000 copies/ml threshold for plasma specimens for correctly classifying patients (Table 3 and Fig 3). Using a dried blood spot specimen threshold of 1,000 copies/ml, all 6 technologies had a sensitivity of detecting a viral load above 1,000 copies/ml of greater than 80%. At the same threshold, the specificity of detecting a viral load below 1,000 copies/ml was over 80% for all technologies except for the Biocentric Generic HIV Charge Virale (55.16%), Hologic Aptima (73.44%), and Roche COBAS TaqMan SPEX (43.86%). Using a higher treatment failure threshold, such as 5,000 copies/ml, for dried blood spot specimens reduced the sensitivity and increased the specificity of all technologies. Finally, HSROC curves were created for those technologies where more than 4 studies were included in the meta-analysis (S4 Fig).
Fig 3

Forest plots of sensitivity and specificity of all studies included in the meta-analysis for each viral load technology using a treatment failure threshold of 1,000 copies/ml.

Abbott RealTime HIV-1 two-spot (a), Abbott RealTime HIV-1 one-spot (b), Biocentric Generic HIV Charge Virale (c), bioMerieux NucliSENS EasyQ HIV-1 (d), Hologic Aptima (e), Roche COBAS TaqMan FVE (f), Roche COBAS TaqMan SPEX (g), Siemens VERSANT HIV-1 RNA (h). Red bars and lines indicate the overall metrics for each viral load technology.

Forest plots of sensitivity and specificity of all studies included in the meta-analysis for each viral load technology using a treatment failure threshold of 1,000 copies/ml.

Abbott RealTime HIV-1 two-spot (a), Abbott RealTime HIV-1 one-spot (b), Biocentric Generic HIV Charge Virale (c), bioMerieux NucliSENS EasyQ HIV-1 (d), Hologic Aptima (e), Roche COBAS TaqMan FVE (f), Roche COBAS TaqMan SPEX (g), Siemens VERSANT HIV-1 RNA (h). Red bars and lines indicate the overall metrics for each viral load technology. Additionally, to better understand the performance of dried blood spot specimens at lower treatment failure thresholds (below 1,000 copies/ml), we compared the 6 predefined treatment treatment failure thresholds—detectable, 200, 400, 500, 600, and 800 copies/ml—between dried blood spot specimens and plasma for each technology and protocol (Table 4). The Biocentric Generic HIV Charge Virale and Roche COBAS TaqMan SPEX technologies had poor specificity (<40%) at all lower thresholds below 1,000 copies/ml. The Siemens Versant had a sensitivity and specificity above 85% when using a threshold of 800 copies/ml; however, the specificity declined to below 80% at a threshold of 600 copies/ml and below 70% with all thresholds below 500 copies/ml. The Abbott RealTime HIV-1 two-spot and Roche COBAS TaqMan FVE protocols had high sensitivities and specificities at all lower thresholds except detectable. The new Abbott RealTime HIV-1 one-spot protocol, however, had high specificities at all lower thresholds, but sensitivity performance was below 85% at the 200 copies/ml and detectable thresholds. The Hologic Aptima had high sensitivities with all thresholds except detectable; however, specificity was lower than 85% at the thresholds of 800 copies/ml and 200 copies/ml. Finally, the bioMérieux NucliSENS EasyQ HIV-1 had sensitivities and specificities greater than 85% at all thresholds.
Table 4

Meta-analysis of clinical metrics overall and for each viral load technology and protocol for treatment failure thresholds below 1,000 copies/ml.

All technologiesAbbott RealTime HIV-1 two-spotAbbott RealTime HIV-1 one-spotBiocentric Generic HIV Charge ViralebioMerieux NucliSENS EasyQ HIV-1Hologic AptimaRoche COBAS TaqMan HIV-1 FVERoche COBAS TaqMan HIV-1 SPEXSiemens VERSANT HIV-1 RNA
n10,8312,0047005311,0621243,0763,190144
DBS:plasma threshold comparisons
Sensitivity (UCL-LCL) 800:80095.04 (91.45–97.17)92.59 (82.86–96.99)91.55 (4.60–99.96)98.64 (43.94–99.99)85.36 (80.27–89.32)93.47 (31.10–99.78)95.35 (87.11–98.42)99.70 (95.62–99.98)91.07 (74.87–97.22)
600:60095.24 (92.21–97.12)92.71 (84.14–96.83)92.95 (0.04–100.00)98.55 (60.16–99.97)88.87 (83.99–92.40)94.54 (27.75–99.87)94.17 (83.85–98.05)99.26 (96.03–99.87)93.45 (84.10–97.47)
500:50095.43 (92.38–97.30)93.11 (84.49–97.11)92.96 (0.00–100.00)98.40 (66.61–99.95)89.04 (84.76–92.22)94.50 (29.45–99.86)93.37 (81.99–97.75)99.22 (95.81–99.86)97.21 (66.06–99.84)
400:40095.51 (92.35–97.41)92.48 (84.11–96.61)94.36 (0.00–100.00)97.79 (60.28–99.92)90.17 (85.52–93.44)94.69 (28.03–99.88)92.26 (80.79–97.13)99.36 (95.26–99.92)97.18 (62.91–99.86)
200:20094.78 (91.11–96.99)90.80 (82.55–95.37)97.18 (0.00–100.00)98.09 (65.21–99.93)89.42 (83.74–93.28)95.01 (22.04–99.92)89.86 (76.26–96.07)99.16 (94.75–99.87)97.67 (71.68–99.86)
Detectable95.39 (90.12–97.91)92.81 (76.47–98.09)93.13 (62.76–99.09)97.98 (59.94–99.94)88.59 (75.29–95.18)75.42 (51.82–89.75)97.10 (58.02–99.88)99.76 (94.64–99.99)90.08 (83.66–94.15)
Specificity (UCL-LCL) 800:80083.56 (71.57–91.12)92.01 (83.14–96.41)99.77 (23.66–100.00)38.14 (10.78–75.88)95.99 (91.31–98.20)72.16 (41.80–90.34)92.86 (64.86–98.92)37.59 (13.30–70.28)86.62 (68.28–95.11)
600:60082.52 (69.82–90.60)92.54 (81.42–97.23)99.77 (12.38–100.00)28.13 (5.97–70.70)95.21 (91.29–97.42)89.34 (50.48–98.57)92.95 (68.03–98.79)32.98 (11.54–64.98)78.77 (60.95–89.82)
500:50080.41 (66.80–89.33)93.16 (81.96–97.61)99.77 (9.33–100.00)23.72 (4.28–68.41)95.27 (91.10–97.54)89.06 (50.38–98.49)91.71 (67.71–98.32)29.63 (9.78–62.04)65.63 (30.99–89.04)
400:40079.81 (65.43–89.20)93.15 (80.02–97.88)99.77 (8.20–100.00)11.35 (0.61–72.77)95.61 (90.73–97.98)88.44 (47.82–98.46)92.04 (67.80–98.45)27.71 (9.04–59.65)64.91 (24.64–91.28)
200:20081.57 (67.54–90.40)97.22 (91.66–99.11)99.78 (5.34–100.00)15.09 (1.30–70.49)92.94 (89.26–95.43)81.48 (71.52–88.52)91.60 (71.21–97.96)25.31 (7.60–58.26)64.68 (26.23–90.41)
Detectable60.98 (34.29–82.40)78.79 (8.46–99.33)93.16 (66.40–98.94)18.62 (4.87–50.58)93.46 (90.43–95.59)87.18 (66.58–95.87)58.09 (6.37–96.58)4.25 (0.17–53.54)69.23 (40.93–87.96)
Total misclassification (UCL-LCL) 800:8009.97 (6.92–14.15)8.39 (5.26–13.11)0.23 (0.00–78.78)11.96 (1.98–47.79)9.03 (6.80–11.91)18.55 (12.65–26.37)10.35 (5.77–17.89)22.44 (11.82–38.44)10.39 (4.12–23.82)
600:6009.12 (6.16–13.30)8.04 (5.01–12.67)0.23 (0.00–84.65)12.85 (1.95–52.18)7.78 (5.64–10.64)6.67 (0.54–48.42)10.42 (6.16–17.09)23.81 (12.52–40.57)11.11 (6.92–17.37)
500:5009.21 (6.15–13.58)7.72 (4.78–12.24)0.23 (0.00–87.30)10.79 (1.09–57.09)7.82 (5.72–10.61)6.67 (0.54–48.43)11.03 (7.08–16.79)25.00 (13.21–42.19)13.19 (8.58–19.76)
400:4008.87 (5.80–13.35)7.94 (5.04–12.29)0.23 (0.00–87.36)9.40 (0.62–63.44)7.50 (5.25–10.62)6.55 (0.49–50.14)10.95 (7.18–16.33)25.35 (13.21–43.11)13.19 (8.58–19.76)
200:2008.04 (4.99–12.70)7.13 (4.11–12.08)0.23 (0.00–88.53)4.33 (0.08–73.07)8.94 (6.41–12.34)6.23 (0.25–63.87)11.01 (7.52–15.83)24.02 (12.02–42.26)10.42 (6.38–16.56)
Detectable8.73 (5.22–14.24)9.64 (4.17–20.74)15.00 (12.54–17.84)4.65 (0.07–76.18)11.26 (6.16–19.71)20.97 (14.69–29.02)7.29 (1.41–30.10)8.26 (2.36–25.14)11.81 (7.47–18.17)
Upward misclassification (UCL-LCL) 800:80016.44 (8.88–28.43)7.99 (3.59–16.86)0.23 (0.00–76.34)61.86 (24.12–89.22)4.01 (1.80–8.69)27.84 (9.66–58.20)7.14 (1.08–35.14)62.41 (29.72–86.70)13.38 (4.89–31.72)
600:60017.48 (9.40–30.18)7.46 (2.77–18.58)0.23 (0.00–87.62)71.87 (29.30–94.03)4.79 (2.58–8.71)10.66 (1.43–49.52)7.05 (1.21–31.97)67.02 (35.02–88.46)21.23 (10.18–39.05)
500:50019.59 (10.67–33.20)6.84 (2.39–18.04)0.23 (0.00–90.67)76.28 (31.59–95.72)4.73 (2.46–8.90)10.94 (1.51–49.62)8.29 (1.68–32.29)70.37 (37.96–90.22)34.37 (10.96–69.01)
400:40020.19 (10.80–34.57)6.85 (2.12–19.98)0.23 (0.00–91.80)88.65 (27.23–99.39)4.39 (2.02–9.27)11.56 (1.54–52.18)7.96 (1.55–32.20)72.29 (40.35–90.96)35.09 (8.72–75.36)
200:20018.43 (9.60–32.46)2.78 (0.89–8.34)0.22 (0.00–94.66)84.91 (29.51–98.70)7.06 (4.57–10.74)18.52 (11.48–28.48)8.40 (2.04–28.79)74.69 (41.74–92.40)35.32 (9.59–73.77)
Detectable39.02 (17.60–65.71)21.21 (0.67–91.54)6.84 (1.06–33.60)81.38 (49.42–95.13)6.54 (4.41–9.57)12.82 (4.13–33.42)41.91 (3.42–93.63)95.75 (46.46–99.83)30.77 (12.04–59.07)
Downward misclassification (UCL-LCL) 800:8004.96 (2.83–8.55)7.41 (3.01–17.14)8.45 (0.04–95.40)1.36 (0.01–56.06)14.64 (10.68–19.73)6.53 (0.22–68.90)4.65 (1.58–12.89)0.30 (0.02–4.38)8.93 (2.78–25.13)
600:6004.76 (2.88–7.79)7.29 (3.17–15.86)7.05 (0.00–99.96)1.45 (0.03–39.84)11.13 (7.60–16.01)5.46 (0.13–72.25)5.83 (1.95–16.15)0.74 (0.13–3.97)6.55 (2.53–15.90)
500:5004.57 (2.70–7.62)6.89 (2.89–15.51)7.04 (0.00–100.00)1.60 (0.05–33.39)10.96 (7.78–15.24)5.50 (0.14–70.55)6.63 (2.25–18.01)0.78 (0.14–4.19)2.79 (0.16–33.94)
400:4004.49 (2.59–7.65)7.52 (3.39–15.89)5.64 (0.00–100.00)2.21 (0.08–39.72)9.83 (6.56–14.48)5.31 (0.12–71.97)7.74 (2.87–19.21)0.64 (0.08–4.74)2.82 (0.14–37.09)
200:2005.22 (3.01–8.89)9.20 (4.63–17.45)2.82 (0.00–100.00)1.91 (0.07–34.79)10.58 (6.72–16.26)4.99 (0.08–77.96)10.14 (3.93–23.74)0.84 (0.13–5.25)2.33 (0.14–28.32)
Detectable4.61 (2.09–9.88)7.19 (1.91–23.53)6.87 (0.91–37.24)2.02 (0.06–40.06)11.41 (4.82–24.71)24.58 (10.25–48.18)2.90 (0.12–41.98)0.24 (0.01–5.36)9.92 (5.85–16.34)
PPV (UCL-LCL) 800:80089.22 (82.88–93.40)93.43 (88.98–96.16)86.67 (11.76–99.69)88.79 (50.70–98.39)96.91 (93.16–98.64)63.04 (48.39–75.64)87.09 (66.28–95.86)67.49 (40.14–86.53)93.44 (82.58–97.71)
600:60089.74 (83.48–93.80)94.46 (89.47–97.16)82.50 (13.38–99.31)88.64 (48.24–98.49)96.13 (91.82–98.21)93.68 (8.52–99.96)89.28 (68.33–96.98)66.39 (38.39–86.23)91.18 (83.90–95.35)
500:50089.50 (83.10–93.66)95.13 (89.88–97.73)80.49 (31.57–97.36)90.95 (47.06–99.13)96.08 (91.90–98.14)93.66 (9.34–99.95)87.39 (69.63–95.44)66.21 (37.81–86.33)88.75 (78.93–94.33)
400:40090.26 (83.87–94.29)95.37 (90.57–97.79)79.76 (21.07–98.31)92.82 (45.93–99.49)96.25 (96.23–96.26)93.67 (8.17–99.96)86.58 (72.16–94.13)66.90 (37.97–86.96)89.88 (78.90–95.47)
200:20093.09 (86.54–96.58)99.14 (93.84–99.89)77.53 (66.60–85.65)96.79 (38.29–99.93)95.31 (90.04–97.86)93.81 (7.53–99.96)87.80 (75.05–94.51)70.56 (39.94–89.62)92.17 (85.64–95.88)
Detectable97.60 (94.45–98.98)99.69 (91.78–99.99)93.25 (53.87–99.39)96.80 (38.43–99.93)96.51 (93.13–98.26)93.69 (35.94–99.75)98.07 (90.92–99.61)92.19 (70.22–98.34)98.67 (65.40–99.97)
NPV (UCL-LCL) 800:80092.83 (87.27–96.07)90.48 (79.65–95.85)99.77 (48.10–100.00)33.65 (1.43–94.65)79.41 (62.31–90.00)92.31 (83.92–96.50)97.39 (94.33–98.82)97.53 (94.81–98.84)78.00 (64.49–87.38)
600:60092.44 (87.13–95.67)89.59 (77.67–95.52)99.77 (56.44–100.00)41.43 (3.28–93.66)83.11 (64.24–93.09)97.05 (31.73–99.96)96.66 (92.95–98.45)96.85 (93.97–98.38)83.33 (68.95–91.84)
500:50092.27 (86.93–95.55)89.73 (79.34–95.21)99.77 (55.62–100.00)34.65 (2.09–92.93)83.19 (65.11–92.92)97.00 (32.11–99.95)95.92 (91.92–97.98)96.20 (92.60–98.08)83.39 (53.74–95.60)
400:40091.83 (85.88–95.41)88.15 (75.52–94.72)99.77 (67.05–100.00)26.51 (2.48–83.67)84.74 (70.14–92.92)93.24 (84.77–97.16)94.71 (89.03–97.53)95.21 (90.77–97.57)81.23 (49.15–95.09)
200:20087.86 (80.59–92.66)82.53 (71.11–90.07)99.79 (91.24–100.00)14.76 (0.24–92.55)79.75 (63.92–89.74)96.57 (27.65–99.95)92.24 (84.69–96.23)93.38 (85.67–97.08)79.31 (60.95–90.40)
Detectable57.74 (41.04–72.84)58.92 (35.49–78.90)93.33 (50.20–99.49)3.19 (0.01–95.43)63.22 (33.93–85.19)68.34 (38.97–87.94)52.90 (27.86–76.57)72.19 (36.12–92.26)21.12 (0.86–89.25)
Quantitative polymerase chain reaction inherently introduces a level of variability in test results, generally +/−0.3 log copies/ml [68,69]. We, therefore, sought to understand if the performance observed with each technology was within the inherent assay variability limits. For the Abbott RealTime HIV-1 two-spot, Abbott RealTime HIV-1 one-spot, Biocentric Generic HIV Charge Virale, bioMérieux NucliSENS EasyQ HIV-1, Hologic Aptima, Roche COBAS TaqMan FVE, Roche COBAS TaqMan SPEX, and Siemens VERSANT HIV-1 RNA technologies, 59.28%, 68.71%, 38.04%, 52.54%, 50.40%, 62.03%, 33.45%, 47.22% of dried blood spot specimen test results were within the standard deviation of +/−0.3 log copies/ml of the paired plasma test result, respectively (Fig 4).
Fig 4

A substantial proportion of dried blood spot results fall outside of the plasma result +/−0.3 log copies/ml for each technology.

Abbott RealTime HIV-1 two-spot (a), Abbott RealTime HIV-1 one-spot (b), Biocentric Generic HIV Charge Virale (c), bioMerieux NucliSENS EasyQ HIV-1 (d), Hologic Aptima (e), Roche COBAS TaqMan FVE (f), Roche COBAS TaqMan SPEX (g), Siemens VERSANT HIV-1 RNA (h). Blue bars represent +/−0.3 log copies/ml of the plasma result, while orange triangles represent the paired dried blood spot viral load result.

A substantial proportion of dried blood spot results fall outside of the plasma result +/−0.3 log copies/ml for each technology.

Abbott RealTime HIV-1 two-spot (a), Abbott RealTime HIV-1 one-spot (b), Biocentric Generic HIV Charge Virale (c), bioMerieux NucliSENS EasyQ HIV-1 (d), Hologic Aptima (e), Roche COBAS TaqMan FVE (f), Roche COBAS TaqMan SPEX (g), Siemens VERSANT HIV-1 RNA (h). Blue bars represent +/−0.3 log copies/ml of the plasma result, while orange triangles represent the paired dried blood spot viral load result.

Sensitivity analyses

We next conducted sensitivity analyses with subsets of the data specific to each technology to understand possible causes of lower analytical and clinical performance (Figs 5 and S5). After including only studies in which manufacturer-recommended procedures for dried blood spot specimen collection and processing were precisely followed, we observed no change in the performance of dried blood spot specimens on each of the viral load platforms (S5 Fig). Similarly, performance of dried blood spot specimens did not change when used with older and newer versions of the assays as well as within ART and ART-naïve patient populations (S5 Fig).
Fig 5

Meta-analysis sub-analyses.

Sensitivity and specificity sub-analyses by venous and capillary preparation (a), dried blood spot filter card type (b), and storage temperature (c) compared to plasma with a treatment failure threshold of 1,000 copies/ml.

Dried blood spot specimens can be prepared and stored in various ways. We, therefore, performed sub-analyses to detect differences in dried blood spot specimen test performance due to venous or capillary blood specimen collection, dried blood spot filter card type, and storage temperature. While the sample size for the capillary specimen collection sub-analysis was relatively small (n = 119), the specificity was reduced compared with venous blood specimens (Fig 5A). No significant difference was observed between the performance of the Munktell TFN filter card and Whatman 903 card types on each of the viral load technologies analyzed (Fig 5B). Similarly, no significant difference was found between the performance of dried blood spot specimens kept at room temperature or frozen (Fig 5C).

Meta-analysis sub-analyses.

Sensitivity and specificity sub-analyses by venous and capillary preparation (a), dried blood spot filter card type (b), and storage temperature (c) compared to plasma with a treatment failure threshold of 1,000 copies/ml.

Discussion

Dried blood spot specimens may increase access to HIV viral load testing for virological monitoring of ART patients in resource-limited settings. This study analyzed the technical performance of laboratory-based viral load technologies for accurate quantification of viral load using dried blood spot specimens compared to plasma specimens. While the performance varied between technologies, the most commonly used viral load technologies, Abbott RealTime HIV-1, bioMérieux NucliSENS EasyQ HIV-1, Roche COBAS TaqMan using the FVE protocol, and Siemens VERSANT HIV-1 RNA performed best and within acceptable limits when using a treatment failure threshold of 1,000 copies/ml. Further, utilizing the same treatment failure threshold for both plasma and dried blood spot specimens will avoid differentiated training and interpretation by specimen type and facilitate viral load scale-up in resource-limited settings. Additionally, this analysis indicated that the use of higher thresholds (e.g., 3,000 or 5,000 copies/ml) for dried blood spot specimen viral load testing will result in higher levels of misclassification of treatment failure with most viral load testing technologies. The sensitivity for 5 technologies were above 90%, however, between 80% to 90% for the Abbott RealTime HIV-1 one-spot, bioMérieux NucliSENS EasyQ HIV-1, and Hologic Aptima assays using a treatment failure threshold of 1,000 copies/ml. Increasing the treatment failure threshold further reduces the sensitivities of all assays. This performance indicated that most patients with an elevated viral load would be identified by all technologies; however, it is important to note that some patients failing treatment will be missed and only retested a year later when using technologies with lower sensitivity. Additionally, 5 technologies had a specificity above 85% using the treatment failure threshold of 1,000 copies/ml. Two technologies, Biocentric Generic HIV Charge Virale and Roche COBAS TaqMan using the SPEX protocol had low specificities of approximately 55% and 44%, respectively, using a treatment failure threshold of 1,000 copies/ml. This performance would be concerning as significant proportions of patients suppressing their viral load would be incorrectly identified as failing treatment; however, additional viral load measurements are required prior treatment switching and thus this misclassification could be resolved. Though some variability was observed with the Roche COBAS TaqMan using the FVE protocol in the meta-analysis, recent studies have shown consistent performance with sensitivity and specificity greater than 90% [51,60]. Furthermore, the Hologic Aptima had a sensitivity of approximately 75%; however, it is important to note that this is a relatively new technology and only 2 studies were included in the meta-analysis. Additional data may support more precise estimates. Furthermore, though technologies have variable performance when using dried blood spot specimens at lower treatment failure thresholds, several technologies and protocols can be considered if lower treatment failure thresholds are required. While the lower limits of detection of dried blood spot specimens tend to be higher than plasma due to the smaller specimen volume that clearly does not preclude the technologies or protocols from correctly classifying patients as failing or not failing treatment, the most critical clinical measurement used. Therefore, limits of detection should not be the primary metric for consideration when reviewing technology performance or selecting one for routine use. Prior to changing guidelines and putting in the significant work to implement such an algorithm change, it is important to consider a range of factors, including the prevalence and clinical relevance of low-level viremia, especially in relation to implementation and scale-up of optimized antiretroviral drugs such as dolutegravir, access to testing, result utilization, and other scale-up priorities to ensure that patients have access to high-quality testing and necessary follow-up clinical care. The sensitivity analyses performed in this study suggest that low adherence to manufacturer-recommended dried blood spot specimen collection and extraction protocols, study geographies, and technology version used did not contribute significantly to any observed differences in dried blood spot and plasma specimen test results. Though the sensitivity analysis including only data generated through compliance with the manufacturers’ recommended protocols did not improve the performance of dried blood spot specimens for viral load testing, manufacturer protocols should be precisely followed for optimal technology performance. Performance variability between test platforms is likely due to different dried blood spot nucleic acid extraction methods and viral load test chemistries employed by each platform. This was observed with the standard Roche COBAS TaqMan SPEX and FVE specimen extraction protocols; the latter protocol was associated with much higher levels of specificity when compared with paired plasma specimen testing. Similarly, the lower specificity of the Biocentric Generic HIV Charge Virale test used in the studies analyzed may reflect a need to optimize specimen extraction for dried blood spot specimens. Viral load testing is known to be inherently variable within limits [76,77]; however, 50% to 60% of the dried blood spot specimen test results on all platforms fell outside the inherent variability commonly accepted to exist in viral load tests, +/−0.3 log copies/ml, of the plasma specimen test result. This highlights the effect of dried blood spot use on variability. The clinical relevance and interpretation of this additional variability is, however, unclear given that a binary threshold above or below 1,000 copies/ml is recommended by WHO to define treatment failure. Further refinement of dried blood spot protocols and testing may allow for more careful quantitative use of this specimen type in the future. This systematic review and meta-analysis had some limitations. Almost all studies in this systematic review and meta-analysis used dried blood spots prepared in laboratories using precision pipetting for consistent measurement of input specimen volumes. Hence, the findings may not reflect performance in the field with less precise specimen collection procedures such as allowing the blood drops to drip from the patient’s finger or heel directly onto filter cards as practiced for HIV early infant diagnosis dried blood spot specimen collection [29,43,54,57,59]. Further analysis of the threshold in the context of the finger-prick/“hang drop” blood sample collection method would be beneficial. Incompletely filled circles, as potentially could be observed in the field using the hanging drop technique, may result in inaccurate test results due to variable blood volumes. Viral load testing, however, is quantitative and requires a precise known amount of input volume, though the impact of variability in input volume, and sampling approaches such as the “hang drop” technique, on clinical misclassification needs further study before use. Accordingly, WHO has recommended the use of precision pipets or measured micro-capillary EDTA tubes to ensure the appropriate volume is added to each specimen spot [78]. Additionally, sample storage and transportation are critically important for dried blood spot specimens; however, this systematic review was unable to review the effect of inappropriate storage and transportation on clinical performance. Furthermore, almost all studies in this systematic review and meta-analysis used the Whatman 903 dried blood spot paper; therefore, additional studies may be needed to better validate other types of dried blood spot collection papers for use with viral load testing. Finally, though nearly 70% of studies provided primary data for inclusion in the meta-analysis, the possibility exists that the data and results of those not included could be slightly different or that the current data set may be biased; however, no clear differences were observed between those studies that provided primary data and those that were unable to do so. The sample sizes for each sub-analysis were small; therefore, further studies are warranted to better understand the performance of dried blood spot specimens under these conditions. Abbott has recently changed their dried blood spot protocol to only use 1 dried blood spot and a different dried blood spot extraction buffer. Data on the new protocol are very limited; however, 2 studies reviewed the performance and found sensitivity and specificity of greater than 90% [58,59]. While additional critical analytical parameters are important such as analytical performance and sensitivity, we focused on the clinical implications. As with all systematic reviews, the search strategy may have missed some titles; however, a significant number of studies and data points were included in both the systematic review and meta-analysis, thus limiting potential biases. Additionally, the time of sample storage was rarely included or defined. Finally, no studies reviewed the use of dried blood spot samples for viral load testing within the longitudinal algorithm currently recommended by the WHO [79]. While this systematic review and meta-analysis informs the use of dried blood spot specimens for viral load testing [79], it is important to note that the performance characteristics described herein used single cross-sectional specimens. WHO guidelines, however, defines treatment failure as 2 consecutive viral load tests greater than 1,000 copies/ml that are at least 3 months apart with adherence counseling after the first viral load. The technical performance of dried blood spot specimens within such a longitudinal treatment failure algorithm is unknown and should be studied further. Furthermore, few manufacturers have sought regulatory approval to use dried blood spot samples for viral load testing. Currently, only the Abbott RealTime HIV-1 one-spot and bioMérieux NucliSENS EasyQ HIV-1 have CE-IVD approval and/or WHO prequalification listing. It is critical, however, for manufacturers to seek regulatory approval to provide better support to countries in need of this additional sample type to further expand access. This study raises an important issue of understanding appropriate and acceptable levels of clinical misclassification for current treatment failure thresholds. The acceptable level of misclassification with viral load tests is, however, unclear and further investigation may be warranted to guide technology development and selection. The gold standard biomarker for viral load testing is circulating HIV RNA in plasma [8,9,11,13,80]. Because plasma viral load testing is not accessible to many HIV patients in resource-limited settings, countries and companies have sought alternative specimen types. Whole blood specimens, however, result in elevated viral loads compared to plasma specimens because of the detection of intracellular RNA and DNA. Alternative specimen input types, such as whole blood, has sparked debate as to the most appropriate biomarker(s) for detecting treatment failure [77,78]. Additional research would provide better insight as to the clinical and virological relevance of intracellular nucleic acids in detecting treatment failure. The meta-analysis presented here offers advantages over previous systematic reviews [81-83], which were limited in robustness by variations in the analysis methodology and sample sizes of individual studies. Systematic reviews also do not allow for data manipulation or sensitivity analyses to draw new relevant conclusions. Meta-analyses have more power to detect real differences compared to individual studies or systematic reviews given that precision estimates increase with pooled data. Further, meta-analyses provide greater insights into the consistency of test results through stronger quantification of the variability of test accuracy across many settings and technologies. In conclusion, though variability was seen between technologies included, several technologies performed best using a treatment failure threshold of 1,000 copies/ml. The Abbott RealTime HIV-1 two- and one-spot, bioMérieux NucliSENS EasyQ HIV-1, Roche COBAS TaqMan using the FVE protocol, and Siemens VERSANT HIV-1 RNA technologies can all be considered for use with dried blood spot specimens when prepared using precision pipets or measured micro-capillary EDTA tubes with a treatment failure threshold of 1,000 copies/ml. It is expected that increased interest in and implementation of viral load testing using dried blood spot specimens may encourage manufacturers to acquire regulatory approval for this specimen type for in vitro diagnostic use, while new technologies such as plasma separation cards may further support the testing landscape.

PRISMA 2020 Checklist.

(PDF) Click here for additional data file.

Flow diagram of updated full search.

(TIF) Click here for additional data file.

QUADAS-2 scores of included studies.

(TIF) Click here for additional data file.

Forest plots of mean bias and limits of agreement for each study included in the systematic review for each technology.

(TIF) Click here for additional data file.

HSROC curves of each study included in the meta-analysis by technology with a treatment failure threshold of 1,000 copies/mL.

Circle sizes were relative to the study sample size. The red square was the pooled summary point. (TIF) Click here for additional data file.

Sensitivity analysis of manufacturer protocol followed: bioMerieux (a), Roche TaqMan SPEX (b); and over time: Abbott 2-spot (c), bioMerieux (d), Roche TaqMan SPEX (e).

(TIFF) Click here for additional data file.

HIV viral load meta-analysis study protocol.

(PDF) Click here for additional data file.
  73 in total

1.  Evaluation of old and new tests of heterogeneity in epidemiologic meta-analysis.

Authors:  B Takkouche; C Cadarso-Suárez; D Spiegelman
Journal:  Am J Epidemiol       Date:  1999-07-15       Impact factor: 4.897

2.  Dried blood spots versus plasma for the quantitation of HIV-1 RNA using a real-Time PCR, m2000rt assay.

Authors:  Madhavan Vidya; Shanmugam Saravanan; Samara Rifkin; Sunil S Solomon; Greer Waldrop; Kenneth H Mayer; Suniti Solomon; Pachamuthu Balakrishnan
Journal:  J Virol Methods       Date:  2012-03-01       Impact factor: 2.014

3.  Misclassification of first-line antiretroviral treatment failure based on immunological monitoring of HIV infection in resource-limited settings.

Authors:  Rami Kantor; Lameck Diero; Allison Delong; Lydia Kamle; Sarah Muyonga; Fidelis Mambo; Eunice Walumbe; Wilfred Emonyi; Philip Chan; E Jane Carter; Joseph Hogan; Nathan Buziba
Journal:  Clin Infect Dis       Date:  2009-08-01       Impact factor: 9.079

4.  Prospective evaluation of diagnostic accuracy of dried blood spots from finger prick samples for determination of HIV-1 load with the NucliSENS Easy-Q HIV-1 version 2.0 assay in Malawi.

Authors:  Emmanuel Fajardo; Carol A Metcalf; Pascale Chaillet; Lucia Aleixo; Pieter Pannus; Isabella Panunzi; Laura Triviño; Tom Ellman; Andrew Likaka; Reuben Mwenda
Journal:  J Clin Microbiol       Date:  2014-02-05       Impact factor: 5.948

5.  HIV-1 viral load measurement in venous blood and fingerprick blood using Abbott RealTime HIV-1 DBS assay.

Authors:  Ning Tang; Vihanga Pahalawatta; Andrea Frank; Zowie Bagley; Raquel Viana; John Lampinen; Gregor Leckie; Shihai Huang; Klara Abravaya; Carole L Wallis
Journal:  J Clin Virol       Date:  2017-05-13       Impact factor: 3.168

6.  Dried blood spot HIV-1 RNA quantification using open real-time systems in South Africa and Burkina Faso.

Authors:  Johannes Viljoen; Sandrine Gampini; Sivapragashini Danaviah; Diane Valéa; Sureshnee Pillay; Dramane Kania; Nicolas Méda; Marie-Louise Newell; Philippe Van de Perre; François Rouet
Journal:  J Acquir Immune Defic Syndr       Date:  2010-11       Impact factor: 3.731

7.  Multicenter evaluation of use of dried blood and plasma spot specimens in quantitative assays for human immunodeficiency virus RNA: measurement, precision, and RNA stability.

Authors:  Don Brambilla; Cheryl Jennings; Grace Aldrovandi; James Bremer; Anne Marie Comeau; Sharon A Cassol; Ruth Dickover; J Brooks Jackson; Jane Pitt; John L Sullivan; Ann Butcher; Lynell Grosso; Patricia Reichelderfer; Susan A Fiscus
Journal:  J Clin Microbiol       Date:  2003-05       Impact factor: 5.948

8.  CD4+ T-cell count monitoring does not accurately identify HIV-infected adults with virologic failure receiving antiretroviral therapy.

Authors:  David M Moore; Anna Awor; Robert Downing; Jonathan Kaplan; Julio S G Montaner; John Hancock; Willy Were; Jonathan Mermin
Journal:  J Acquir Immune Defic Syndr       Date:  2008-12-15       Impact factor: 3.731

9.  Measure of viral load by using the Abbott Real-Time HIV-1 assay on dried blood and plasma spot specimens collected in 2 rural dispensaries in Cameroon.

Authors:  André Dieudonné Mbida; Samuel Sosso; Pierre Flori; Henia Saoudin; Philip Lawrence; Marcel Monny-Lobé; Yves Oyono; Edward Ndzi; Giulia Cappelli; Frédéric Lucht; Bruno Pozzetto; Odile Ouwe Missi Oukem-Boyer; Thomas Bourlet
Journal:  J Acquir Immune Defic Syndr       Date:  2009-09-01       Impact factor: 3.731

10.  Evaluation of quantification of HIV-1 RNA viral load in plasma and dried blood spots by use of the semiautomated Cobas Amplicor assay and the fully automated Cobas Ampliprep/TaqMan assay, version 2.0, in Kisumu, Kenya.

Authors:  Kenneth N Ouma; Sridhar V Basavaraju; Jully A Okonji; John Williamson; Timothy K Thomas; Lisa A Mills; John N Nkengasong; Clement Zeh
Journal:  J Clin Microbiol       Date:  2013-02-06       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.