Literature DB >> 22401801

Dried blood spots versus plasma for the quantitation of HIV-1 RNA using a real-Time PCR, m2000rt assay.

Madhavan Vidya1, Shanmugam Saravanan, Samara Rifkin, Sunil S Solomon, Greer Waldrop, Kenneth H Mayer, Suniti Solomon, Pachamuthu Balakrishnan.   

Abstract

High costs and stringent requirements for storage and transport of plasma, often prohibit the availability of HIV viral load quantification in resource-limited settings. Dried blood spots (DBS) represent a better method of specimen collection that removes many of these logistical and technical limitations. The present study aimed to assess the performance of the Abbott m2000rt assay for quantitation of HIV-1 RNA in DBS specimens using plasma as a "gold standard" for comparison. One hundred paired DBS and plasma specimens were collected from patients infected with HIV, who were 18 years and older during routine visits to a private tertiary-care clinic in Chennai, India. HIV-1 RNA was extracted manually and then detected using the m2000rt assay. The mean plasma and DBS viral loads were 4.27 (95% CI: 2.65, 5.88) and 4.14 (95% CI: 1.96, 6.32) log copies/mL, respectively. The overall sensitivity of DBS reached 95%; with sensitivities of 62%, 88% and 100% when stratified by viral load ranges of ≤1000, 1000-3000 and >3000 copies/mL, respectively. An over quantitation of the viral load with DBS was observed in pairs with plasma viral load<3000 copies/mL [d=-0.3 log copies/mL (ranging from -0.1 to 0.6 log copies/mL)]. The study showed a strong concordance in RNA levels between plasma and DBS. The use of DBS specimens should be considered for HIV monitoring and for detection of virologic failure in resource-limited settings.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22401801     DOI: 10.1016/j.jviromet.2012.02.006

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  14 in total

1.  Field evaluation of dried blood spots for routine HIV-1 viral load and drug resistance monitoring in patients receiving antiretroviral therapy in Africa and Asia.

Authors:  Marjorie Monleau; Avelin F Aghokeng; Sabrina Eymard-Duvernay; Anoumou Dagnra; Dramane Kania; Nicole Ngo-Giang-Huong; Coumba Touré-Kane; Lien X T Truong; Marie-Laure Chaix; Eric Delaporte; Ahidjo Ayouba; Martine Peeters
Journal:  J Clin Microbiol       Date:  2013-12-11       Impact factor: 5.948

2.  Comparison of the Gen-Probe Aptima HIV-1 and Abbott HIV-1 qualitative assays with the Roche Amplicor HIV-1 DNA assay for early infant diagnosis using dried blood spots.

Authors:  Julie A E Nelson; J Tyler Hawkins; Maria Schanz; Katie Mollan; Melissa B Miller; John L Schmitz; Susan A Fiscus
Journal:  J Clin Virol       Date:  2014-06-02       Impact factor: 3.168

3.  Measures of viral load using Abbott RealTime HIV-1 Assay on venous and fingerstick dried blood spots from provider-collected specimens in Malawian District Hospitals.

Authors:  Sarah E Rutstein; Deborah Kamwendo; Lebah Lugali; Isaac Thengolose; Gerald Tegha; Susan A Fiscus; Julie A E Nelson; Mina C Hosseinipour; Abdoulaye Sarr; Sundeep Gupta; Frank Chimbwandira; Reuben Mwenda; Ronald Mataya
Journal:  J Clin Virol       Date:  2014-05-22       Impact factor: 3.168

Review 4.  Developments in CD4 and viral load monitoring in resource-limited settings.

Authors:  Christopher F Rowley
Journal:  Clin Infect Dis       Date:  2013-11-11       Impact factor: 9.079

Review 5.  Diagnosis of Human Immunodeficiency Virus Infection.

Authors:  Bharat S Parekh; Chin-Yih Ou; Peter N Fonjungo; Mireille B Kalou; Erin Rottinghaus; Adrian Puren; Heather Alexander; Mackenzie Hurlston Cox; John N Nkengasong
Journal:  Clin Microbiol Rev       Date:  2018-11-28       Impact factor: 26.132

6.  Plasmodium vivax: reverse transcriptase real-time PCR for gametocyte detection and quantitation in clinical samples.

Authors:  Nathália F Lima; Melissa S Bastos; Marcelo U Ferreira
Journal:  Exp Parasitol       Date:  2012-08-24       Impact factor: 2.011

Review 7.  Systematic review of the use of dried blood spots for monitoring HIV viral load and for early infant diagnosis.

Authors:  Pieter W Smit; Kimberly A Sollis; Susan Fiscus; Nathan Ford; Marco Vitoria; Shaffiq Essajee; David Barnett; Ben Cheng; Suzanne M Crowe; Thomas Denny; Alan Landay; Wendy Stevens; Vincent Habiyambere; Joseph H Perriens; Rosanna W Peeling
Journal:  PLoS One       Date:  2014-03-06       Impact factor: 3.240

8.  Evaluation of Two Techniques for Viral Load Monitoring Using Dried Blood Spot in Routine Practice in Vietnam (French National Agency for AIDS and Hepatitis Research 12338).

Authors:  Fabien Taieb; Tran Hong Tram; Hien Thi Ho; Van Anh Pham; Lan Nguyen; Ban Hien Pham; Linh An Tong; Edouard Tuaillon; Eric Delaporte; Anh Tuan Nguyen; Duc Duong Bui; NhanThi Do; Yoann Madec
Journal:  Open Forum Infect Dis       Date:  2016-07-07       Impact factor: 3.835

9.  First field evaluation of the optimized CE marked Abbott protocol for HIV RNA testing on dried blood spot in a routine clinical setting in Vietnam.

Authors:  Fabien Taieb; Tram Tran Hong; Hien Thi Ho; Binh Nguyen Thanh; Tram Pham Phuong; Dung Viet Ta; Nhung Le Thi Hong; Hien Ba Pham; Lan Thi Huong Nguyen; Huong Thi Nguyen; Thu Trang Nguyen; Edouard Tuaillon; Eric Delaporte; Huong Le Thi; Hau Tran Thi Bich; Tuan Anh Nguyen; Yoann Madec
Journal:  PLoS One       Date:  2018-02-09       Impact factor: 3.240

10.  Dried blood spot testing: filling the gap between antiretroviral treatment & monitoring in India.

Authors:  M Zazzi
Journal:  Indian J Med Res       Date:  2012-12       Impact factor: 2.375

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.