| Literature DB >> 32713347 |
Murat Kocaoglu1, Amol S Pednekar2,3, Hui Wang1,4,5, Tarek Alsaied6,7, Michael D Taylor6,7, Mantosh S Rattan1,4.
Abstract
BACKGROUND: Although the breath-hold cine balanced steady state free precession (bSSFP) imaging is well established for assessment of biventricular volumes and function, shorter breath-hold times or no breath-holds are beneficial in children and severely ill or sedated patients.Entities:
Keywords: Children; Compressed SENSE; Free-breathing cine; Left ventricular indices; Pediatric; Right ventricular indices
Mesh:
Year: 2020 PMID: 32713347 PMCID: PMC7384228 DOI: 10.1186/s12968-020-00642-y
Source DB: PubMed Journal: J Cardiovasc Magn Reson ISSN: 1097-6647 Impact factor: 5.364
Characteristics of the study population
| Number of patients | 26 |
|---|---|
| Age (years) | 16.7 ± 6.4 (9–35) |
| Female-to-male ratio | 6:20 |
| Height (cm) | 154.3 ± 21.9 (121–191) |
| Weight (kg) | 61 ± 26 (24–134) |
| BSA (m2) | 1.59 ± 0.38 (0.94–2.44) |
| Heart rate (beats/min) | 83 ± 17 (50–115) |
| Clinical Indications | |
| Duchenne muscular dystrophy | 12 |
| Pectus excavatum | 10 |
| Becker muscular dystrophy | 1 |
| Marfan syndrome | 1 |
| Turner syndrome | 1 |
| Chemotherapy induced cardiomyopathy | 1 |
The data are presented as the mean ± standard deviation (minimum – maximum) or as the number of subjects
BSA body surface area
Fig. 1Tukey box plots of (a) imaging duration, (b) blood-to-myocardial contrast (BMC) normalized to myocardial signal, and (c) image quality scores for three short-axis acquisitions. Imaging duration includes gaps between breath-holds. One-to-one line plots (dotted black lines) for imaging duration with breath hold (BH) C-SENSE = 3 and free breathing (FB) C-SENSE = 3 depict the dependence of imaging duration on the patient’s heart rate–to–respiratory rate ratio. BMC of FB C-SENSE = 3 scan was significantly lower (p < 0.05) than both BH SENSE = 2 and BH C-SENSE = 3 acquisitions. Center red line = median, whiskers = minimum and maximum within 1.5 times interquartile distance, red ★ = outliers beyond 1.5 times the interquartile distance. Non-overlapping notches indicate that the medians of the two groups differ at the 5% significance level. Black * with bracket indicates two groups are significantly different (p < 0.05). ART = artifacts; CS3 C-SENSE acceleration factor of 3; EED = endocardial edge delineation; S2 SENSE acceleration factor of 2; TOT = total combined score
Left and Right Ventricular Volumetric Indices and Difference in their Values between Breath-hold with SENSE Acceleration Factor of 2, Breath-hold with C-SENSE Acceleration Factor of 3, and Free-breathing Sequence with C-SENSE Acceleration Factor of 3 (All Subjects)
| Imaging Sequence | Difference | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| BH S2 | BH CS3 | FB CS3 | BH S2 - BH CS3 | BH S2 - FB CS3 | BH CS3 - FB CS3 | BH S2 - BH CS3 | BH S2 - FB CS3 | BH CS3 - FB CS3 | |
| 127.2 ± 46.2 | 125.2 ± 45.8 | 130.2 ± 45.9 | 2.0 ± 6.9 | −3.0 ± 6.8 | −5.0 ± 7.7 | 0.142 | 0.036* | 0.003* | |
| 79.3 ± 18.7 | 77.8 ± 17.5 | 81.0 ± 17.6 | 1.5 ± 4.7 | −1.8 ± 4.2 | −3.3 ± 5.1 | 0.122 | 0.043* | 0.003* | |
| 52.0 ± 21.7 | 50.8 ± 21.2 | 54.0 ± 22.6 | 1.2 ± 4.4 | −2.0 ± 4.8 | −3.2 ± 4.3 | 0.191 | 0.042* | < 0.001* | |
| 32.2 ± 9.4 | 31.4 ± 8.6 | 33.4 ± 9.3 | 0.8 ± 3.0 | −1.1 ± 2.9 | −2.0 ± 2.7 | 0.184 | 0.058 | 0.001* | |
| 75.3 ± 27.0 | 74.4 ± 27.4 | 76.2 ± 26.1 | 0.9 ± 5.8 | −0.9 ± 6.4 | −1.8 ± 6.0 | 0.440 | 0.463 | 0.131 | |
| 47.0 ± 11.4 | 46.4 ± 11.2 | 47.7 ± 10.8 | 0.7 ± 3.6 | −0.6 ± 4.2 | −1.3 ± 3.9 | 0.351 | 0.458 | 0.098 | |
| 59.6 ± 5.5 | 59.7 ± 6.1 | 59.1 ± 6.2 | −0.2 ± 2.8 | 0.5 ± 3.5 | 0.7 ± 2.4 | 0.748 | 0.480 | 0.172 | |
| 63.2 ± 20.3 | 65.2 ± 20.9 | 63.6 ± 21.0 | −2.0 ± 4.3 | −0.4 ± 7.3 | 1.6 ± 6.6 | 0.026* | 0.764 | 0.237 | |
| 39.4 ± 7.2 | 40.5 ± 7.0 | 39.6 ± 7.8 | −1.1 ± 2.9 | −0.2 ± 4.6 | 1.0 ± 4.0 | 0.063 | 0.854 | 0.237 | |
| 121.1 ± 44.6 | 117.9 ± 43.5 | 123.9 ± 45.8 | 3.2 ± 6.2 | −2.8 ± 9.6 | −6.0 ± 8.5 | 0.015* | 0.153 | 0.001* | |
| 75.6 ± 19.8 | 73.3 ± 18.1 | 77.2 ± 19.8 | 2.3 ± 4.2 | −1.6 ± 6.0 | −3.9 ± 5.7 | 0.009* | 0.196 | 0.002* | |
| 51.9 ± 22.6 | 48.7 ± 20.4 | 52.9 ± 22.5 | 3.2 ± 5.5 | −1.0 ± 5.9 | −4.2 ± 6.8 | 0.007* | 0.384 | 0.004* | |
| 32.1 ± 11.2 | 30.1 ± 9.7 | 32.8 ± 11.3 | 2.0 ± 3.7 | −0.7 ± 3.9 | −2.7 ± 4.8 | 0.010* | 0.391 | 0.008* | |
| 69.3 ± 24.2 | 69.2 ± 24.5 | 71.0 ± 25.0 | 0.0 ± 5.3 | −1.7 ± 5.9 | −1.8 ± 3.9 | 0.985 | 0.144 | 0.030* | |
| 43.5 ± 10.6 | 43.2 ± 9.5 | 44.4 ± 10.0 | 0.3 ± 3.1 | −0.9 ± 3.5 | −1.2 ± 2.5 | 0.621 | 0.203 | 0.024* | |
| 58.1 ± 5.9 | 59.5 ± 4.8 | 58.2 ± 5.9 | −1.4 ± 3.5 | −0.1 ± 2.9 | 1.2 ± 3.6 | 0.054 | 0.820 | 0.094 | |
Unless otherwise indicated, data are means ± standard deviations
BH breath-hold, BSA body surface area, CS3 C-SENSE acceleration factor of 3, EDV end-diastolic volume, EF ejection fraction, ESV end-systolic volume, FB free-breathing, LV left ventricle, RV right ventricle, S2 SENSE acceleration factor of 2, SV stroke volume
The * represents p < 0.05
Fig. 2Linear regression and Bland-Altman plots comparing left ventricular (LV) stroke volume (SV) measured with aortic quantitative flow with that measured from bSSFP cine short-axis images acquired with (a) BH SENSE = 2, (b) BH C-SENSE = 3, and BH breath-hold, CS3 C-SENSE acceleration factor of 3, FB free-breathing, S2 SENSE acceleration factor of 2
Fig. 3Bar-plot analysis of image quality scores depicts percentage of patients who had image quality scores of excellent, good, adequate, suboptimal, or non-diagnostic in each grading criteria based on blood-to-myocardial contrast (BMC), endocardial edge definition (EED), and presence of artifacts (ART) and total (TOT) combined score. The combined image quality score is the equal-weight average of the three scores, which underscores the overall performance of the technique
Fig. 4Representative balanced steady-state free precession short-axis images of 5 patients (columns) with combined clinical scores: breath-hold (BH) with SENSE factor of 2 (top row), breath-hold with C-SENSE factor of 3 (middle row), and free-breathing (FB) with C-SENSE factor of 3(bottom row). The combined image quality score is the equal-weight average of score in three criteria: blood-to-myocardial contrast (BMC), endocardial edge definition (EED), and presence of artifacts throughout the cardiac cycle. Each criterion was graded on a scale of 1 to 5, where 1 is nondiagnostic, 2 is suboptimal but still diagnostic for volumetric analysis, 3 is adequate, 4 is good, and 5 is excellent. Patient in (1) had dark papillary muscles and endocardial trabeculae clearly visible with crisp edge definition on bright backdrop of the blood pool throughout the cardiac cycle in all slices in all the three sequences. Patient in (2) had mild degradation of edge definition in all three sequences. For the patient in (3), there was mild degradation of edge definition only in FB C-SENSE sequence in couple of slices. Patient in (4) had mild degradation of edge definition for all three sequences, additionally both BH C-SENSE and FB C-SENSE sequences had slightly less BMC. For patient in (5), there were mild parallel imaging and motion artifacts for BH SENSE sequence, while BH C-SENSE sequence had only mild degradation of the edge definition, and FB C-SENSE sequences had substantial motion artifacts. BH = breath-hold, FB = free-breathing cardiorespiratory synchronized retrospectively cardiac gated balanced steady-state free precession cine CMR sequence