Literature DB >> 11930076

MR Imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolutions on left ventricular functional parameters.

Stephan Miller1, Orlando P Simonetti, James Carr, Ulrich Kramer, J Paul Finn.   

Abstract

The influence of changes in spatial and temporal resolutions on functional parameters in the left ventricle (LV) were investigated with magnetic resonance (MR) imaging with a modified true fast imaging with steady-state precession, or FISP, two-dimensional sequence that provided temporal resolution of 21-90 msec and spatial resolution of 1-3 mm. MR imaging in the heart was performed in 15 healthy volunteers. A decrease in LV functional parameters was observed with reduced spatial and temporal resolutions. The influence of temporal resolution was more relevant.

Entities:  

Mesh:

Year:  2002        PMID: 11930076     DOI: 10.1148/radiol.2231010235

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  50 in total

1.  Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Olaf Dietrich; Johannes Rieber; Matthias Nittka; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2003-05-29       Impact factor: 5.315

2.  3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI.

Authors:  Dana C Peters; Daniel B Ennis; Pratik Rohatgi; Mushabbar A Syed; Elliot R McVeigh; Andrew E Arai
Journal:  J Magn Reson Imaging       Date:  2004-09       Impact factor: 4.813

3.  [Determining global heart function with real time TrueFISP in one respiratory cycle].

Authors:  B J Wintersperger; K Nikolaou; O Mühling; A Huber; O Dietrich; M Nittka; B Kiefer; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2004-02       Impact factor: 0.635

4.  Correlation between ECG abnormalities and cardiac parameters in highly trained asymptomatic male endurance athletes: evaluation using cardiac magnetic resonance imaging.

Authors:  Gunnar Erz; Stefanie Mangold; Erik Franzen; Claus D Claussen; Andreas M Niess; Christof Burgstahler; Ulrich Kramer
Journal:  Int J Cardiovasc Imaging       Date:  2012-06-22       Impact factor: 2.357

Review 5.  Novel techniques for assessment of left ventricular systolic function.

Authors:  Sonal Chandra; Hicham Skali; Ron Blankstein
Journal:  Heart Fail Rev       Date:  2011-07       Impact factor: 4.214

6.  Functional parameters of the left ventricle: comparison of cardiac MRI and cardiac CT in a large population.

Authors:  A Palumbo; E Maffei; C Martini; G Messalli; S Seitun; R Malagò; A Aldrovandi; E Emiliano; A Cuttone; A Weustink; N Mollet; F Cademartiri
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

7.  Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography.

Authors:  Martin Heuschmid; Julia K Rothfuss; Stephen Schroeder; Michael Fenchel; Norbert Stauder; Christof Burgstahler; Andreas Franow; Ronald S Kuzo; Axel Kuettner; Stephan Miller; Claus D Claussen; Andreas F Kopp
Journal:  Eur Radiol       Date:  2005-10-08       Impact factor: 5.315

8.  Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T.

Authors:  Matthias Gutberlet; Kerstin Schwinge; Patrick Freyhardt; Birgit Spors; Matthias Grothoff; Timm Denecke; Lutz Lüdemann; Ralph Noeske; Thoralf Niendorf; Roland Felix
Journal:  Eur Radiol       Date:  2005-05-05       Impact factor: 5.315

9.  Evaluation of right ventricular function with multidetector computed tomography: comparison with magnetic resonance imaging and analysis of inter- and intraobserver variability.

Authors:  Mira Müller; Florian Teige; Dirk Schnapauff; Bernd Hamm; Marc Dewey
Journal:  Eur Radiol       Date:  2008-08-15       Impact factor: 5.315

10.  Auto-SENSE view-sharing cine cardiac imaging.

Authors:  H Köstler; M Beer; C Ritter; D Hahn; J Sandstede
Journal:  MAGMA       Date:  2004-08-28       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.