Literature DB >> 15968648

Analysis and compensation of eddy currents in balanced SSFP.

O Bieri1, M Markl, K Scheffler.   

Abstract

Balanced steady-state free precession (SSFP) completely compensates for all gradients within each repetition time (TR), and is thus very sensitive to any magnetic field imperfection that disturbs the perfectly balanced acquisition scheme. It is demonstrated that balanced SSFP is especially sensitive to changing eddy currents that are induced by stepwise changing phase-encoding (PE) gradients. In contrast to the linear k-space trajectory, which has small variations between consecutive encoding steps, other encoding schemes (e.g., centric, random, or segmented orderings) exhibit significant jumps in k-space between adjacent PE steps, and consequently induce rapidly changing eddy currents. The resulting disturbances induce significant image artifacts, such that compensation strategies are essential when nonlinear PE schemes are applied. Although direct annihilation of the induced eddy currents by additional, opposing magnetic fields has been investigated, it is limited by uncertainty regarding the time evolution of induced eddy currents. A generic (and thus system-unrelated) compensation strategy is proposed that consists of "pairing" of consecutive PE steps. Another approach is based on partial dephasing along the slice direction that annihilates eddy-current-induced signal oscillations. Both pairing of the PE steps and "through-slice equilibration" are easy to implement and allow the use of arbitrary k-space trajectories for balanced SSFP.

Mesh:

Year:  2005        PMID: 15968648     DOI: 10.1002/mrm.20527

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  53 in total

1.  Fast chemical shift mapping with multiecho balanced SSFP.

Authors:  Jochen Leupold; Oliver Wieben; Sven Månsson; Oliver Speck; Klaus Scheffler; J Stefan Petersson; Jürgen Hennig
Journal:  MAGMA       Date:  2006-11-22       Impact factor: 2.310

2.  Pulse sequences for phase-contrast SSFP imaging from a single steady-state.

Authors:  J-F Nielsen; K S Nayak
Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib       Date:  2006-05

3.  Interleaved balanced SSFP imaging: artifact reduction using gradient waveform grouping.

Authors:  Jon-Fredrik Nielsen; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2009-03       Impact factor: 4.813

4.  A noncontrast-enhanced pulse sequence optimized to visualize human peripheral vessels.

Authors:  Kjell-Inge Gjesdal; Tryggve Storaas; Jonn-Terje Geitung
Journal:  Eur Radiol       Date:  2008-08-15       Impact factor: 5.315

Review 5.  MR-guided endovascular interventions: a comprehensive review on techniques and applications.

Authors:  Sebastian Kos; Rolf Huegli; Georg M Bongartz; Augustinus L Jacob; Deniz Bilecen
Journal:  Eur Radiol       Date:  2007-12-11       Impact factor: 5.315

6.  Whole-heart coronary MR angiography using a 3D cones phyllotaxis trajectory.

Authors:  Mario O Malavé; Corey A Baron; Nii Okai Addy; Joseph Y Cheng; Phillip C Yang; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2018-10-29       Impact factor: 4.668

7.  Characterization of spatial distortion in a 0.35 T MRI-guided radiotherapy system.

Authors:  John S Ginn; Nzhde Agazaryan; Minsong Cao; Umar Baharom; Daniel A Low; Yingli Yang; Yu Gao; Peng Hu; Percy Lee; James M Lamb
Journal:  Phys Med Biol       Date:  2017-04-20       Impact factor: 3.609

8.  Self-gated fat-suppressed cardiac cine MRI.

Authors:  R Reeve Ingle; Juan M Santos; William R Overall; Michael V McConnell; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2014-05-07       Impact factor: 4.668

9.  Self-calibrated trajectory estimation and signal correction method for robust radial imaging using GRAPPA operator gridding.

Authors:  Anagha Deshmane; Martin Blaimer; Felix Breuer; Peter Jakob; Jeffrey Duerk; Nicole Seiberlich; Mark Griswold
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

10.  Multiple repetition time balanced steady-state free precession imaging.

Authors:  Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.