PURPOSE: To prospectively determine the accuracy of four-dimensional (4D) kt-broad-use linear acquisition speed-up technique (BLAST) accelerated MRI (kt-BLAST) for the assessment of left-ventricular (LV) volumes and mass as well as right-ventricular (RV) volumes in comparison to standard multiple breathhold cine imaging. MATERIALS AND METHODS: A total of 40 patients with suspected or known coronary artery disease (CAD) underwent cardiac MRI. In each patient a standard multislice cine steady-state free precession (SSFP) sequence was performed with complete ventricular coverage during multiple breathholds. Additionally, a kt-BLAST-accelerated 4D sequence with complete ventricular coverage was acquired during one single breathhold. For comparison of SSFP and kt-BLAST, the following LV parameters were determined: end-diastolic and end-systolic volumes, ejection fraction, end-diastolic diameter and mass. For comparison of RV dimensions, end-diastolic and end-systolic volumes and ejection fraction were assessed. RESULTS: LV volumes, ejection fraction, diameter, and mass showed a strong correlation between SSFP and kt-BLAST (r=0.98-0.99; P<0.01). In addition, RV parameters demonstrated a high correlation (r=0.97-0.98; P<0.01). For all parameters, the calculated bias between both methods was found to be minimal (0.4-4%). CONCLUSION: 4D kt-BLAST-accelerated MRI enabled the accurate assessment of LV and RV quantitative parameters during one single breathhold when compared to standard multislice, multiple breathhold SSFP imaging. Copyright (c) 2007 Wiley-Liss, Inc.
PURPOSE: To prospectively determine the accuracy of four-dimensional (4D) kt-broad-use linear acquisition speed-up technique (BLAST) accelerated MRI (kt-BLAST) for the assessment of left-ventricular (LV) volumes and mass as well as right-ventricular (RV) volumes in comparison to standard multiple breathhold cine imaging. MATERIALS AND METHODS: A total of 40 patients with suspected or known coronary artery disease (CAD) underwent cardiac MRI. In each patient a standard multislice cine steady-state free precession (SSFP) sequence was performed with complete ventricular coverage during multiple breathholds. Additionally, a kt-BLAST-accelerated 4D sequence with complete ventricular coverage was acquired during one single breathhold. For comparison of SSFP and kt-BLAST, the following LV parameters were determined: end-diastolic and end-systolic volumes, ejection fraction, end-diastolic diameter and mass. For comparison of RV dimensions, end-diastolic and end-systolic volumes and ejection fraction were assessed. RESULTS: LV volumes, ejection fraction, diameter, and mass showed a strong correlation between SSFP and kt-BLAST (r=0.98-0.99; P<0.01). In addition, RV parameters demonstrated a high correlation (r=0.97-0.98; P<0.01). For all parameters, the calculated bias between both methods was found to be minimal (0.4-4%). CONCLUSION: 4D kt-BLAST-accelerated MRI enabled the accurate assessment of LV and RV quantitative parameters during one single breathhold when compared to standard multislice, multiple breathhold SSFP imaging. Copyright (c) 2007 Wiley-Liss, Inc.
Authors: Holger C Eberle; Kai Nassenstein; Christoph J Jensen; Thomas Schlosser; Georg V Sabin; Christoph K Naber; Oliver Bruder Journal: Eur Radiol Date: 2009-07-25 Impact factor: 5.315
Authors: Juliane Goebel; Felix Nensa; Bettina Bomas; Haemi P Schemuth; Stefan Maderwald; Marcel Gratz; Harald H Quick; Thomas Schlosser; Kai Nassenstein Journal: Eur Radiol Date: 2016-03-09 Impact factor: 5.315
Authors: Jian Xu; Daniel Kim; Ricardo Otazo; Monvadi B Srichai; Ruth P Lim; Leon Axel; Kelly Anne Mcgorty; Thoralf Niendorf; Daniel K Sodickson Journal: J Magn Reson Imaging Date: 2012-11-29 Impact factor: 4.813
Authors: Anil K Attili; Andreas Schuster; Eike Nagel; Johan H C Reiber; Rob J van der Geest Journal: Int J Cardiovasc Imaging Date: 2010-02 Impact factor: 2.357
Authors: Marcus R Makowski; Andrea J Wiethoff; Christian H P Jansen; Sergio Uribe; Victoria Parish; Andreas Schuster; Rene M Botnar; Aaron Bell; Christoph Kiesewetter; Reza Razavi; Tobias Schaeffter; Gerald F Greil Journal: J Cardiovasc Magn Reson Date: 2012-07-31 Impact factor: 5.364