| Literature DB >> 31978974 |
Fernando Zarone1, Gennaro Ruggiero1, Maria Irene Di Mauro1, Gianrico Spagnuolo1, Marco Ferrari2, Roberto Sorrentino1.
Abstract
BACKGROUND: This study was aimed at comparing the accuracy of impressions of a reference typodont (RT) reproducing a totally edentulous maxilla made with three impression materials: polysulfide, polyether, and polyvinyl-siloxane.Entities:
Keywords: accuracy; digital dentistry; digital model; edentulous maxilla impression; elastomer; laboratory scanner; optical impression; polyether; polysulfide; polyvinyl siloxane
Year: 2020 PMID: 31978974 PMCID: PMC7040790 DOI: 10.3390/ma13030515
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Figure 1Reference typodont (RT) in polyurethane resin.
Figure 2Physical impressions made of: (a) polysulfide; (b) polyvinyl siloxane; (c) polyether.
Figure 3Standardized testing device for impression making.
Figure 4(a) Scan of a physical impression obtained from the extraoral laboratory scanner; (b) Digital model obtained from the inversion of the scan of a physical impression.
Figure 5Evaluation of trueness and precision: best superimposition for each group of scans. The green areas indicate a minimum displacement of the digital model compared to the reference data, while red and blue areas indicate an outward and inward displacement between the surfaces, respectively.
Descriptive statistics for trueness (µm).
| Material Scanned | Lower-Upper Bound (95% CI) | Mean | Standard Error |
|---|---|---|---|
| polysulfide | 121.3–378.5 | 249.9 | 56.8531 |
| polyvinyl siloxane | 123.1–310.6 | 216.8 | 41.4459 |
| polyether | 219.9–362.3 | 291.1 | 31.4736 |
Figure 6Box plot chart of trueness values. The central rectangle spans the first quartile to the third quartile and whiskers above and below the box show the locations of the minimum and maximum. The segments inside the rectangle shows the median, and unfilled circles represent suspected outliers.
Descriptive statistics for precision (µm).
| Material Scanned | Lower-Upper Bound (95% CI) | Mean | Standard Error |
|---|---|---|---|
| polysulfide | 108.8–415 | 261.9 | 66.4043 |
| polyvinyl siloxane | 111.9–306.8 | 209.4 | 42.2547 |
| polyether | 227.9–338.1 | 283 | 23.8969 |
Figure 7Box plot chart of precision values. The central rectangle spans the first quartile to the third quartile and whiskers above and below the box show the locations of the minimum and maximum. The segments inside the rectangle shows the median, and unfilled circles represent suspected outliers.