Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology.

J Bryan McLaughlin1, Van Ramos2, Douglas P Dickinson3.   

Abstract

PURPOSE: To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested.
MATERIALS AND METHODS: Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture.
RESULTS: Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding.
CONCLUSION: Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from the use of injection molding compared to CAD/CAM and compression molding.
© 2017 by the American College of Prosthodontists.

Entities:  

Keywords:  3D printing; CAD/CAM; arch form; complete dentures; computer-aided design; denture bases; digital dentures; injection molding; maxilla; maxillary arch; palate; palate depth; removable; selective laser sintering; titanium

Mesh:

Substances:

Year:  2017        PMID: 29136309     DOI: 10.1111/jopr.12604

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  5 in total

Review 1.  Assessment of Conventionally and Digitally Fabricated Complete Dentures: A Comprehensive Review.

Authors:  Manal Q Mubaraki; Mohammed M Al Moaleem; Abdulrahman H Alzahrani; Mansoor Shariff; Saeed M Alqahtani; Amit Porwal; Fuad A Al-Sanabani; Shilpa Bhandi; João Paulo Mendes Tribst; Artak Heboyan; Shankargouda Patil
Journal:  Materials (Basel)       Date:  2022-05-28       Impact factor: 3.748

2.  Comparison of cooling methods on denture base adaptation of rapid heat-cured acrylic using a three-dimensional superimposition technique.

Authors:  Lee Wei May; Jacob John; Lim Ghee Seong; Zubaidah Zanul Abidin; Norliza Ibrahim; Mahmoud Danaee; Noorhayati Raja Mohd
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

3.  Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method.

Authors:  Suji Lee; Seoung-Jin Hong; Janghyun Paek; Ahran Pae; Kung-Rock Kwon; Kwantae Noh
Journal:  J Adv Prosthodont       Date:  2019-02-26       Impact factor: 1.904

4.  Accuracy of Three Impression Materials on the Totally Edentulous Maxilla: In Vitro/In Silico Comparative Analysis.

Authors:  Fernando Zarone; Gennaro Ruggiero; Maria Irene Di Mauro; Gianrico Spagnuolo; Marco Ferrari; Roberto Sorrentino
Journal:  Materials (Basel)       Date:  2020-01-22       Impact factor: 3.623

5.  Duplicating Complete Dentures with Conventional and Digital Methods: Comparisons of Trueness and Efficiency.

Authors:  Li Chen; Deli Li; Jianfeng Zhou; Wei-Shao Lin; Jianguo Tan
Journal:  Dent J (Basel)       Date:  2022-03-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.