Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method.

R Nedelcu1, P Olsson2, I Nyström3, J Rydén4, A Thor5.   

Abstract

OBJECTIVE: To evaluate a novel methodology using industrial scanners as a reference, and assess in vivo accuracy of 3 intraoral scanners (IOS) and conventional impressions. Further, to evaluate IOS precision in vivo.
METHODS: Four reference-bodies were bonded to the buccal surfaces of upper premolars and incisors in five subjects. After three reference-scans, ATOS Core 80 (ATOS), subjects were scanned three times with three IOS systems: 3M True Definition (3M), CEREC Omnicam (OMNI) and Trios 3 (TRIOS). One conventional impression (IMPR) was taken, 3M Impregum Penta Soft, and poured models were digitized with laboratory scanner 3shape D1000 (D1000). Best-fit alignment of reference-bodies and 3D Compare Analysis was performed. Precision of ATOS and D1000 was assessed for quantitative evaluation and comparison. Accuracy of IOS and IMPR were analyzed using ATOS as reference. Precision of IOS was evaluated through intra-system comparison.
RESULTS: Precision of ATOS reference scanner (mean 0.6 μm) and D1000 (mean 0.5 μm) was high. Pairwise multiple comparisons of reference-bodies located in different tooth positions displayed a statistically significant difference of accuracy between two scanner-groups: 3M and TRIOS, over OMNI (p value range 0.0001 to 0.0006). IMPR did not show any statistically significant difference to IOS. However, deviations of IOS and IMPR were within a similar magnitude. No statistical difference was found for IOS precision.
CONCLUSION: The methodology can be used for assessing accuracy of IOS and IMPR in vivo in up to five units bilaterally from midline. 3M and TRIOS had a higher accuracy than OMNI. IMPR overlapped both groups. CLINICAL SIGNIFICANCE: Intraoral scanners can be used as a replacement for conventional impressions when restoring up to ten units without extended edentulous spans.
Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

Keywords:  Accuracy; Digital impression; In vivo; Intraoral scanner; Polyether impression; Precision

Mesh:

Substances:

Year:  2017        PMID: 29246490     DOI: 10.1016/j.jdent.2017.12.006

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  41 in total

1.  Evaluation of different registration methods and dental restorations on the registration duration and accuracy of cone beam computed tomography data and intraoral scans: a retrospective clinical study.

Authors:  Xing-Yu Piao; Ji-Man Park; Hannah Kim; Youngjun Kim; June-Sung Shim
Journal:  Clin Oral Investig       Date:  2022-05-10       Impact factor: 3.606

2.  Digital intraoral scanner devices: a validation study based on common evaluation criteria.

Authors:  Ivett Róth; Alexandra Czigola; Dóra Fehér; Viktória Vitai; Gellért Levente Joós-Kovács; Péter Hermann; Judit Borbély; Bálint Vecsei
Journal:  BMC Oral Health       Date:  2022-04-26       Impact factor: 3.747

3.  In vitro Comparison of the Accuracy (Precision and Trueness) of Seven Dental Scanners.

Authors:  Fariborz Vafaee; Farnaz Firouz; Mahsa Mohajeri; Reza Hashemi; Somayeh Ghorbani Gholiabad
Journal:  J Dent (Shiraz)       Date:  2021-03

4.  Accuracy of commercial intraoral scanners.

Authors:  Mattia Sacher; Georg Schulz; Hans Deyhle; Kurt Jäger; Bert Müller
Journal:  J Med Imaging (Bellingham)       Date:  2021-05-24

5.  Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study.

Authors:  Francesco Guido Mangano; Uli Hauschild; Giovanni Veronesi; Mario Imburgia; Carlo Mangano; Oleg Admakin
Journal:  BMC Oral Health       Date:  2019-06-06       Impact factor: 2.757

6.  The Effects of Orthodontic Brackets on the Time and Accuracy of Digital Impression Taking.

Authors:  Hyojin Heo; Minji Kim
Journal:  Int J Environ Res Public Health       Date:  2021-05-16       Impact factor: 3.390

Review 7.  Trueness and precision of digital implant impressions by intraoral scanners: a literature review.

Authors:  Minoru Sanda; Keita Miyoshi; Kazuyoshi Baba
Journal:  Int J Implant Dent       Date:  2021-07-27

Review 8.  The Chairside Periodontal Diagnostic Toolkit: Past, Present, and Future.

Authors:  Tae-Jun Ko; Kevin M Byrd; Shin Ae Kim
Journal:  Diagnostics (Basel)       Date:  2021-05-22

9.  Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: an in vitro descriptive comparison.

Authors:  Robert Nedelcu; Pontus Olsson; Ingela Nyström; Andreas Thor
Journal:  BMC Oral Health       Date:  2018-02-23       Impact factor: 2.757

10.  Trueness and Precision of Three-Dimensional Digitizing Intraoral Devices.

Authors:  Hussam Mutwalli; Michael Braian; Deyar Mahmood; Christel Larsson
Journal:  Int J Dent       Date:  2018-11-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.