Literature DB >> 14508741

A retrospective comparison of two definitive impression techniques and their associated postinsertion adjustments in complete denture prosthodontics.

Carl J Drago1.   

Abstract

PURPOSE: To compare the number of postinsertion adjustment visits required by edentulous patients whose dentures were made from border-molded definitive impressions using modeling plastic impression compound (traditional technique) with patients whose dentures were made from border-molded definitive impressions using heavy-body vinyl polysiloxane impression material.
MATERIALS AND METHODS: In this retrospective clinical study, 78 patients were treated with the traditional technique (custom impression trays border molded with gray modeling plastic impression compound) and 78 were treated with the modified technique (custom impression trays border molded with heavy-body vinyl polysiloxane impression material). In both techniques, definitive wash impressions were made with light-body vinyl polysiloxane impression material. Postinsertion visits were quantified for 1 year after the dentures were inserted.
RESULTS: The average number of adjustment visits for patients treated with the traditional technique was 2.68. The average number of adjustment visits for patients treated with the modified technique was 2.68. The data were compared using Student t tests. There was no significant difference in the number of adjustments required for patients whose dentures were made with either technique (t = 0.000, p = 1.00). There was no significant difference in the number of post-insertion visits required by patients from either population.
CONCLUSIONS: Within the limitations of this clinical study, border-molding custom denture impression trays with vinyl polysiloxane impression material provided similar results in terms of postinsertion visits for one year as compared to dentures made from impressions border molded with modeling plastic impression compound.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14508741     DOI: 10.1016/S1059-941X(03)00082-2

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  9 in total

1.  A systematic review of impression technique for conventional complete denture.

Authors:  Shubha Rao; R Chowdhary; S Mahoorkar
Journal:  J Indian Prosthodont Soc       Date:  2010-12-17

2.  Comparative evaluation of border molding, using two different techniques in maxillary edentulous arches - An in vivo study.

Authors:  Rameshbabu Yarapatineni; Abhishek Vilekar; J Phani Kumar; G Ajay Kumar; Prasad Aravind; P Anil Kumar
Journal:  J Int Oral Health       Date:  2013-12-26

3.  Frequency of Traumatic Ulcerations and Post-insertion Adjustment Recall Visits in Complete Denture Patients in an Iranian Faculty of Dentistry.

Authors:  Katayoun Sadr; Farhang Mahboob; Elaheh Rikhtegar
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2011-06-14

4.  Comparison of different final impression techniques for management of resorbed mandibular ridge: a case report.

Authors:  Bhupender Yadav; Manisha Jayna; Harish Yadav; Shrey Suri; Shefali Phogat; Reshu Madan
Journal:  Case Rep Dent       Date:  2014-08-10

5.  Traumatic Ulcerations Frequencies and Postinsertion Adjustment Appointments in Complete Denture Patients.

Authors:  Sony Saraswati; Priyanka Razdan; Monika Aggarwal; Devleena Bhowmick; Priyanka Priyadarshni
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10

Review 6.  The elastomers for complete denture impression: A review of the literature.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2010-07-17

Review 7.  Final-impression techniques and materials for making complete and removable partial dentures.

Authors:  Srinivasan Jayaraman; Balendra P Singh; Balasubramanian Ramanathan; Murukan Pazhaniappan Pillai; Laura MacDonald; Richard Kirubakaran
Journal:  Cochrane Database Syst Rev       Date:  2018-04-04

8.  A randomised controlled trial of complete denture impression materials.

Authors:  T P Hyde; H L Craddock; J C Gray; S H Pavitt; C Hulme; M Godfrey; C Fernandez; N Navarro-Coy; S Dillon; J Wright; S Brown; G Dukanovic; P A Brunton
Journal:  J Dent       Date:  2014-07-01       Impact factor: 4.379

9.  Accuracy of Three Impression Materials on the Totally Edentulous Maxilla: In Vitro/In Silico Comparative Analysis.

Authors:  Fernando Zarone; Gennaro Ruggiero; Maria Irene Di Mauro; Gianrico Spagnuolo; Marco Ferrari; Roberto Sorrentino
Journal:  Materials (Basel)       Date:  2020-01-22       Impact factor: 3.623

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.