Literature DB >> 30580982

Edentulous jaw impression techniques: An in vivo comparison of trueness.

Najla Chebib1, Nicole Kalberer2, Murali Srinivasan3, Sabrina Maniewicz2, Thomas Perneger4, Frauke Müller5.   

Abstract

STATEMENT OF PROBLEM: Simplified edentulous jaw impression techniques have gained popularity, while their validity has not yet been evaluated.
PURPOSE: The purpose of this clinical study was to compare the trueness of maxillary edentulous jaw impressions made with irreversible hydrocolloid (ALG), polyvinyl siloxane (PVS), PVS modified with zinc oxide eugenol (ZOE) (PVSM), and an intraoral scanner (TRI) with a conventionally border-molded ZOE impression (control).
MATERIAL AND METHODS: Twelve edentulous maxillary impressions were made with the impression techniques. The analog impressions were scanned using a laboratory scanner, imported into 3-dimensional comparison software, and superimposed against the corresponding control. Trueness was evaluated by calculating the effective deviation known as root mean square (RMS) for the entire surface (ES) and for specific regions of interest such as peripheral border, inner seal, midpalatal suture, ridge, and posterior palatal seal. The secondary outcomes for this study were the patients' perception of the impression techniques. Statistical analyses with the Wilcoxon tests were carried out (α=.05).
RESULTS: For ES, significant differences were found when comparing ALG (1.21 ±0.35 mm) with PVS (0.75 ±0.17 mm; P=.008), PVSM (0.75 ±0.19 mm; P=.012), and TRI (0.70 ±0.18 mm; P=.006) but not among the other groups. Significant differences were found for peripheral border when comparing ALG (2.03 ±0.55 mm) with PVS (1.12 ±0.32 mm; P=.006), PVSM (1.05 ±0.29 mm; P=.003), and TRI (1.38 ±0.25 mm; P=.008), as well as TRI and PVSM (P=.028). Significant differences were also found for inner seal when comparing ALG (0.74 ±0.36 mm) with PVSM (0.52 ±0.13 mm; P=.041), as well as TRI (0.8 ±0.25 mm) versus PVS (0.56 ±0.14 mm; P=.005) and PVSM (P=.005). The difference at the ridge was significant when comparing PVS (0.18 ±0.07 mm) with PVSM (0.28 ±0.19 mm; P=.015) but not among the other groups. A significant difference was also found for posterior palatal seal when comparing PVS (0.55 ±0.41 mm) with PVSM (0.60 ±0.43 mm; P=.034). Patient perceptions showed significantly better satisfaction scores for ALG (1.83 ±2.03) and PVS (3.17 ±2.40) than for TRI (4.08 ±2.71), PVSM (4.58 ±2.35), and ZOE (6.83 ±1.75).
CONCLUSIONS: Edentulous impressions made with PVS, PVSM, and TRI had similar deviations and may yield clinically acceptable results. Irreversible hydrocolloids are contraindicated for definitive impression making in completely edentulous jaws.
Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30580982     DOI: 10.1016/j.prosdent.2018.08.016

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  5 in total

1.  In silico evaluation of the peripheral and inner seals in complete denture master impressions using a custom-developed 3D software.

Authors:  Nicole Kalberer; Najla Chebib; Wolfgang Wachter; Hyeonjong Lee; Frauke Müller; Murali Srinivasan
Journal:  Clin Oral Investig       Date:  2020-06-02       Impact factor: 3.573

2.  Misfit of Complete Maxillary Dentures' Posterior Palatal Seal following Polymerisation with Four Different Autopolymerising Resins: An In Vitro Study.

Authors:  Simone Schiller; Elke Rustemeier; Dominik Kraus; Helmut Stark; Frauke Müller; Karl-Heinz Utz
Journal:  Materials (Basel)       Date:  2022-07-30       Impact factor: 3.748

3.  Applying intraoral scanner to residual ridge in edentulous regions: in vitro evaluation of inter-operator validity to confirm trueness.

Authors:  Akinori Tasaka; Yuuki Uekubo; Tomoharu Mitsui; Takao Kasahara; Takuya Takanashi; Shinya Homma; Satoru Matsunaga; Shinichi Abe; Masao Yoshinari; Yasutomo Yajima; Kaoru Sakurai; Shuichiro Yamashita
Journal:  BMC Oral Health       Date:  2019-12-02       Impact factor: 2.757

4.  Accuracy of Three Impression Materials on the Totally Edentulous Maxilla: In Vitro/In Silico Comparative Analysis.

Authors:  Fernando Zarone; Gennaro Ruggiero; Maria Irene Di Mauro; Gianrico Spagnuolo; Marco Ferrari; Roberto Sorrentino
Journal:  Materials (Basel)       Date:  2020-01-22       Impact factor: 3.623

5.  Application of intraoral scanner to identify monozygotic twins.

Authors:  Botond Simon; Laura Lipták; Klaudia Lipták; Ádám Domonkos Tárnoki; Dávid László Tárnoki; Dóra Melicher; János Vág
Journal:  BMC Oral Health       Date:  2020-10-02       Impact factor: 2.757

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.