Literature DB >> 29615324

Comparing the accuracy (trueness and precision) of models of fixed dental prostheses fabricated by digital and conventional workflows.

Ji-Young Sim1, Yeon Jang1, Woong-Chul Kim1, Hae-Young Kim2, Dong-Hwan Lee3, Ji-Hwan Kim4.   

Abstract

PURPOSE: This study aimed to evaluate and compare the accuracy.
METHODS: A reference model was prepared with three prepared teeth for three types of restorations: single crown, 3-unit bridge, and inlay. Stone models were fabricated from conventional impressions. Digital impressions of the reference model were created using an intraoral scanner (digital models). Physical models were fabricated using a three-dimensional (3D) printer. Reference, stone, and 3D printed models were subsequently scanned using an industrial optical scanner; files were exported in a stereolithography file format. All datasets were superimposed using 3D analysis software to evaluate the accuracy of the complete arch and trueness of the preparations. One-way and two-way analyses of variance (ANOVA) were performed to compare the accuracy among the three model groups and evaluate the trueness among the three types of preparation.
RESULTS: For the complete arch, significant intergroup differences in precision were observed for the three groups (p<.001). However, no significant difference in trueness was found between the stone and digital models (p>.05). 3D printed models had the poorest accuracy. A two-way ANOVA revealed significant differences in trueness among the model groups (p<.001) and types of preparation (p<.001).
CONCLUSIONS: Digital models had smaller root mean square values of trueness of the complete arch and preparations than stone models. However, the accuracy of the complete arch and trueness of the preparations of 3D printed models were inferior to those of the other groups.
Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

Keywords:  3D printed model; Accuracy; Intraoral scanner; Precision; Trueness

Mesh:

Year:  2018        PMID: 29615324     DOI: 10.1016/j.jpor.2018.02.002

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  5 in total

1.  [Influence of trueness for local finish lines of a full crown preparation on that of complete finish line].

Authors:  N Jiang; X D Bao; L Yue
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-09-30

2.  Impact of Aging on the Accuracy of 3D-Printed Dental Models: An In Vitro Investigation.

Authors:  Tim Joda; Lea Matthisson; Nicola U Zitzmann
Journal:  J Clin Med       Date:  2020-05-12       Impact factor: 4.241

3.  Three-Dimensional Evaluation on Accuracy of Conventional and Milled Gypsum Models and 3D Printed Photopolymer Models.

Authors:  Jae-Won Choi; Jong-Ju Ahn; Keunbada Son; Jung-Bo Huh
Journal:  Materials (Basel)       Date:  2019-10-25       Impact factor: 3.623

4.  Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study.

Authors:  Mohamed Fattouh; Laila Mohamed Mohamed Kenawi; Hesham Fattouh
Journal:  Imaging Sci Dent       Date:  2021-08-11

5.  Accuracy of Three Impression Materials on the Totally Edentulous Maxilla: In Vitro/In Silico Comparative Analysis.

Authors:  Fernando Zarone; Gennaro Ruggiero; Maria Irene Di Mauro; Gianrico Spagnuolo; Marco Ferrari; Roberto Sorrentino
Journal:  Materials (Basel)       Date:  2020-01-22       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.