Literature DB >> 10407534

Intra-oral temperature variation over 24 hours.

R J Moore1, J T Watts, J A Hood, D J Burritt.   

Abstract

This study aimed to investigate temperature variation at archwire sites adjacent to the maxillary right central incisor and first premolar, its correlation with ambient temperature, and the influence of inter-racial variation. Twenty young adult male subjects were randomly selected (13 Asian, seven Caucasian). Thermocouples were attached to the labial archwire component of custom-made orthodontic retainers at the two intra-oral sites. A third thermocouple measured ambient temperature. A data-logger recorded temperatures at 5-second intervals over a 24-hour period. Temperatures ranged from 5.6 to 58.5 degrees C at the incisor and from 7.9 to 54 degrees C at the premolar, with medians of 34.9 degrees C and 35.6 degrees C, respectively. Ambient temperature correlated poorly with the intra-oral temperatures. The Asian and Caucasian groups had significantly different temperature distributions. On average during the 24-hour period, temperatures at the incisor site were in the range of 33-37 degrees C for 79 per cent of the time, below it for 20 per cent, and above it for only 1 per cent of the time. Corresponding figures for the premolar site were 92, 6, and 2 per cent. At both archwire sites the most frequent temperatures were in the range of 35-36 degrees C. The data presented demonstrate that the temperature at sites on an archwire in situ varies considerably over a 24-hour period and that racial differences may exist. This information should be considered during the manufacture and use of temperature-sensitive orthodontic materials, in particular nickel-titanium archwires and springs.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10407534     DOI: 10.1093/ejo/21.3.249

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  23 in total

1.  Applicative characteristics of new microelectronic sensors Smart Retainer® and TheraMon® for measuring wear time.

Authors:  Timm Cornelius Schott; Gernot Göz
Journal:  J Orofac Orthop       Date:  2010-10-21       Impact factor: 1.938

2.  Racemization in enamel among different types of teeth from the same individual.

Authors:  Susumu Ohtani; Rei Ito; Szilvia Arany; Toshiharu Yamamoto
Journal:  Int J Legal Med       Date:  2005-01-12       Impact factor: 2.686

3.  Laboratory validation of a new gas-enhanced dentine liquid permeation evaluation system.

Authors:  Anas Al-Jadaa; Thomas Attin; Timo Peltomäki; Christian Heumann; Patrick R Schmidlin
Journal:  Clin Oral Investig       Date:  2014-01-18       Impact factor: 3.573

4.  Characterization of a marine-derived dextranase and its application to the prevention of dental caries.

Authors:  Yu-Liang Jiao; Shu-Jun Wang; Ming-Sheng Lv; Bing-Hua Jiao; Wei-Juan Li; Yao-Wei Fang; Shu Liu
Journal:  J Ind Microbiol Biotechnol       Date:  2013-11-07       Impact factor: 3.346

5.  The effect of temperature on the mechanical behavior of nickel-titanium orthodontic initial archwires.

Authors:  Luca Lombardo; Giorgia Toni; Filippo Stefanoni; Francesco Mollica; Maria Paola Guarneri; Giuseppe Siciliani
Journal:  Angle Orthod       Date:  2012-08-22       Impact factor: 2.079

6.  Color fading of the blue compliance indicator encapsulated in removable clear Invisalign Teen® aligners.

Authors:  Timm Cornelius Schott; Gernot Göz
Journal:  Angle Orthod       Date:  2011-03       Impact factor: 2.079

7.  Torsional superelasticity of NiTi archwires.

Authors:  Yves Bolender; Anne Vernière; Christophe Rapin; Marie-Pierryle Filleul
Journal:  Angle Orthod       Date:  2010-11       Impact factor: 2.079

8.  Objective assessment of patient compliance with removable orthodontic appliances: a cross-sectional cohort study.

Authors:  George Tsomos; Björn Ludwig; Johannes Grossen; Pawel Pazera; Nikolaos Gkantidis
Journal:  Angle Orthod       Date:  2013-07-08       Impact factor: 2.079

9.  Strategies used to inhibit postoperative swelling following removal of impacted lower third molar.

Authors:  Francesco Sortino; Marco Cicciù
Journal:  Dent Res J (Isfahan)       Date:  2011-10

10.  In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment.

Authors:  Giancarlo Cordasco; Antonino Lo Giudice; Angela Militi; Riccardo Nucera; Giuseppe Triolo; Giovanni Matarese
Journal:  Korean J Orthod       Date:  2012-08-28       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.