Literature DB >> 31531963

Comparative analysis on the effect of low-thermal plasma dissection device (PEAK PlasmaBlade) vs conventional electrosurgery in post-bariatric abdominoplasty: A retrospective randomised clinical study.

Torsten Schlosshauer1, Marcus Kiehlmann1, Marc-Oliver Riener2,3, Robert Sader4, Ulrich M Rieger1.   

Abstract

Post-bariatric patients undergoing abdominoplasty have a relatively high risk of complications due to residual obesity and major comorbidities. Also, conventional electrosurgery and the associated thermal tissue damage may compromise outcomes. This retrospective randomised clinical study evaluated the effect of low-thermal plasma dissection device (PEAK [pulsed electron avalanche knife] PlasmaBlade) in comparison with conventional electrosurgery. A total of 52 post-bariatric patients undergoing abdominoplasty were randomised to PEAK PlasmaBlade (n = 26) and to monopolar electrosurgery (n = 26). Wounds of 20 patients per group were examined histologically for acute thermal injury depth. In PEAK PlasmaBlade incisions, acute thermal damage was significantly reduced compared with standard of care (40% vs 75%; P = .035). Also, acute thermal injury depth from PEAK PlasmaBlade was less than that from electrosurgery (2780 μm vs 4090 μm). Significantly less total complication rate (30.8% vs 69.2%; P = .012) was found by PEAK PlasmaBlade compared with electrosurgery. Moreover, the PEAK PlasmaBlade showed less than half as many wound healing problems (19.2% vs 46.2%; P = .075), far fewer secondary bleeding (7.7% vs 30.8%; P = .075), and no seroma compared with four seroma with the standard of care (0% vs 15.4%; P = .11). PEAK PlasmaBlade appears to be superior to traditional monopolar electrosurgery for post-bariatric abdominoplasty, because it demonstrated significantly less tissue damage, less total complication rate, and fewer postoperative seroma resulting in faster wound healing.
© 2019 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

Entities:  

Keywords:  PEAK PlasmaBlade; abdominoplasty; body contouring; electrosurgery; massive weight loss

Mesh:

Year:  2019        PMID: 31531963      PMCID: PMC7949000          DOI: 10.1111/iwj.13221

Source DB:  PubMed          Journal:  Int Wound J        ISSN: 1742-4801            Impact factor:   3.315


  32 in total

1.  Effects of the pulsed electron avalanche knife on retinal tissue.

Authors:  Daniel V Palanker; Michael F Marmor; Andre Branco; Philip Huie; Jason M Miller; Steven R Sanislo; Alexander Vankov; Mark S Blumenkranz
Journal:  Arch Ophthalmol       Date:  2002-05

2.  Comparative analysis on the effect of low-thermal plasma dissection device (PEAK PlasmaBlade) versus conventional electro surgery in post-bariatric body-contouring procedures: A retrospective randomised clinical study.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Pablo Ramirez; Marc-Oliver Riener; Gabriel Djedovic; Ulrich M Rieger
Journal:  Int Wound J       Date:  2019-04-01       Impact factor: 3.315

3.  Comparative healing of surgical incisions created by the PEAK PlasmaBlade, conventional electrosurgery, and a scalpel.

Authors:  Shang A Loh; Grace A Carlson; Edward I Chang; Eric Huang; Daniel Palanker; Geoffrey C Gurtner
Journal:  Plast Reconstr Surg       Date:  2009-12       Impact factor: 4.730

4.  Comparative healing of rat fascia following incision with three surgical instruments.

Authors:  Edward I Chang; Grace A Carlson; Joshua G Vose; Eric J Huang; George P Yang
Journal:  J Surg Res       Date:  2011-01-22       Impact factor: 2.192

5.  Histologic evaluation of porcine skin incisions produced by CO2 laser, electrosurgery, and scalpel.

Authors:  D S Arashiro; J W Rapley; C M Cobb; W J Killoy
Journal:  Int J Periodontics Restorative Dent       Date:  1996-10       Impact factor: 1.840

6.  Comparative analysis on the effect of low-thermal plasma dissection device (PEAK PlasmaBlade) vs conventional electrosurgery in post-bariatric abdominoplasty: A retrospective randomised clinical study.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Marc-Oliver Riener; Robert Sader; Ulrich M Rieger
Journal:  Int Wound J       Date:  2019-09-17       Impact factor: 3.315

7.  Improved wound healing with a modified electrosurgical electrode.

Authors:  P E Butler; C Barry-Walsh; B Curren; P A Grace; M Leader; D Bouchier-Hayes
Journal:  Br J Plast Surg       Date:  1991-10

8.  [Abdominoplasty complications: particularities of the post-bariatric patients within a 238 patients series].

Authors:  L Lievain; A Aktouf; I Auquit-Auckbur; D Coquerel-Beghin; M Scotte; P-Y Milliez
Journal:  Ann Chir Plast Esthet       Date:  2014-09-22       Impact factor: 0.660

9.  Abdominoplasty, liposuction of the flanks, and obesity: analyzing risk factors for seroma formation.

Authors:  James Kim; Thomas R Stevenson
Journal:  Plast Reconstr Surg       Date:  2006-03       Impact factor: 4.730

10.  Complications of abdominoplasty after weight loss as a result of bariatric surgery or dieting/postpregnancy.

Authors:  Trude Staalesen; Monika Fagevik Olsén; Anna Elander
Journal:  J Plast Surg Hand Surg       Date:  2012-10-23
View more
  6 in total

1.  Effect of low-thermal dissection device versus conventional electrocautery in mastectomy for female-to-male transgender patients.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Marc-Oliver Riener; Jens Rothenberger; Robert Sader; Ulrich M Rieger
Journal:  Int Wound J       Date:  2020-05-05       Impact factor: 3.315

2.  Comparative analysis on the effect of low-thermal plasma dissection device (PEAK PlasmaBlade) vs conventional electrosurgery in post-bariatric abdominoplasty: A retrospective randomised clinical study.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Marc-Oliver Riener; Robert Sader; Ulrich M Rieger
Journal:  Int Wound J       Date:  2019-09-17       Impact factor: 3.315

3.  Complications associated with PEAK PlasmaBlade from 2010 to 2020 from MAUDE.

Authors:  Esther Lee; Amir Elzomor; Sameh Boulos; Olivia Silva; Luke J Pasick; Daniel A Benito; Jane Tong; Philip Zapanta; Arjun S Joshi; Joseph F Goodman; Punam G Thakkar
Journal:  Proc (Bayl Univ Med Cent)       Date:  2022-05-19

Review 4.  The Global Prevalence of Seroma After Abdominoplasty: A Systematic Review and Meta-Analysis.

Authors:  Nader Salari; Behnaz Fatahi; Yalda Bartina; Mohsen Kazeminia; Mohammadbagher Heydari; Masoud Mohammadi; Mahvan Hemmati; Shamarina Shohaimi
Journal:  Aesthetic Plast Surg       Date:  2021-06-02       Impact factor: 2.708

5.  Comparative healing of swine skin following incisions with different surgical devices.

Authors:  Yuting Zhong; Yufan Wei; Ningning Min; Qingyu Guan; Jin Zhao; Junyong Zhu; Huayu Hu; Rui Geng; Chenyan Hong; Yashuang Ji; Jie Li; Yiqiong Zheng; Yanjun Zhang; Xiru Li
Journal:  Ann Transl Med       Date:  2021-10

6.  Post-Bariatric Plastic Surgery: Abdominoplasty, the State of the Art in Body Contouring.

Authors:  Payam Sadeghi; Daniela Duarte-Bateman; Wanyan Ma; Ryan Khalaf; R'ay Fodor; Gorizio Pieretti; Feliciano Ciccarelli; Hamed Harandi; Roberto Cuomo
Journal:  J Clin Med       Date:  2022-07-25       Impact factor: 4.964

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.