Literature DB >> 1954512

Improved wound healing with a modified electrosurgical electrode.

P E Butler1, C Barry-Walsh, B Curren, P A Grace, M Leader, D Bouchier-Hayes.   

Abstract

Previous studies comparing standard electrosurgical (ES) electrode and steel scalpel (SS) wound healing have reported poor initial tensile strength, a delay in reaching maximum tensile strength and an increased inflammatory response in the ES wounds. The hypothesis that a smaller needle (modified) electrode would give better wound healing than a standard electrode was tested. Using histology as a parameter of wound healing, incisions created by a modified electrode, a standard electrode and a steel scalpel were compared. Sixty Sha Sha mice were divided into 10 groups. Standardised dorsal skin incisions were made using steel scalpel, standard and modified electrosurgical cutting electrodes. Mice were sacrificed on days 0, 1, 2, 3, 5, 7, 9, 14, 28 and 42. The incised skin was processed for standard and immunohistochemical staining. The standard ES wound had significantly higher numbers of polymorphonuclear leukocytes in comparison to the SS and modified ES wounds (p less than or equal to 0.01). However, macrophage numbers were found to be significantly lower in the ES wounds when compared to the SS wounds on days two and five (p less than or equal to 0.05). The fibroblast response was delayed by up to two days in the ES wounds when compared to the SS wounds. Epithelialisation was completed by day two in the SS and modified ES groups but was only complete by day three in the standard ES group (p less than or equal to 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 1954512     DOI: 10.1016/0007-1226(91)90004-4

Source DB:  PubMed          Journal:  Br J Plast Surg        ISSN: 0007-1226


  9 in total

1.  Comparative analysis on the effect of low-thermal plasma dissection device (PEAK PlasmaBlade) versus conventional electro surgery in post-bariatric body-contouring procedures: A retrospective randomised clinical study.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Pablo Ramirez; Marc-Oliver Riener; Gabriel Djedovic; Ulrich M Rieger
Journal:  Int Wound J       Date:  2019-04-01       Impact factor: 3.315

2.  Effect of low-thermal dissection device versus conventional electrocautery in mastectomy for female-to-male transgender patients.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Marc-Oliver Riener; Jens Rothenberger; Robert Sader; Ulrich M Rieger
Journal:  Int Wound J       Date:  2020-05-05       Impact factor: 3.315

3.  Comparative analysis on the effect of low-thermal plasma dissection device (PEAK PlasmaBlade) vs conventional electrosurgery in post-bariatric abdominoplasty: A retrospective randomised clinical study.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Marc-Oliver Riener; Robert Sader; Ulrich M Rieger
Journal:  Int Wound J       Date:  2019-09-17       Impact factor: 3.315

4.  A Randomized Control Trial to Assess Intraoperative and Postoperative Outcomes of Colorado Microdissection Needle Versus Conventional Surgical Knife in Neck Dissection.

Authors:  Praveen Satish Kumar; Edlyn Rodrigues; Vikas Dhupar; Sthita Gurrala
Journal:  J Maxillofac Oral Surg       Date:  2020-04-30

5.  Healing comparison of porcine cutaneous incisions made with cold steel scalpel, standard electrosurgical blade, and a novel tissue dissector.

Authors:  Albert Y Wu; Thomas J Baldwin; Bhupendra C Patel; Jeffrey W Clymer; Ryan D Lewis
Journal:  Med Res Innov       Date:  2017-10-27

6.  Safety of colorado microdissection needle (stryker) for skin opening in craniomaxillofacial surgery.

Authors:  Rohit Sharma
Journal:  J Maxillofac Oral Surg       Date:  2011-03-18

7.  Traditional electrosurgery and a low thermal injury dissection device yield different outcomes following bilateral skin-sparing mastectomy: a case report.

Authors:  Richard E Fine; Joshua G Vose
Journal:  J Med Case Rep       Date:  2011-05-28

8.  Modified microdissection electrocautery needle.

Authors:  Virendra Singh; Pramod Kumar
Journal:  Natl J Maxillofac Surg       Date:  2014 Jul-Dec

9.  Comparing the outcomes of incisions made by colorado microdissection needle, electrosurgery tip, and surgical blade during periodontal surgery: A randomized controlled trial.

Authors:  Rampalli Viswa Chandra; Boya Savitharani; Aileni Amarender Reddy
Journal:  J Indian Soc Periodontol       Date:  2016 Nov-Dec
  9 in total