Literature DB >> 31486877

Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 1: computed tomography.

David Célier1, Patrice Roch2, Cécile Etard2, Hubert Ducou Le Pointe3,4,5, Hervé J Brisse5,6,7.   

Abstract

OBJECTIVES: To report on a dose survey conducted by the French societies of radiology and paediatric imaging (SFR and SFIPP) and the French public service expert in nuclear and radiological risks (IRSN), and to suggest new diagnostic reference levels (DRLs) for paediatric CT.
METHODS: Dose reports concerning children aged 0-15 years and five CT procedures (brain, petrous bone, mediastinum, lung and abdomen-pelvis) performed in 2015-2016 were collected from 15 imaging departments on a voluntary basis. Volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded for at least 10 patients per procedure, per centre and per age group. New DRLs were calculated as the 3rd quartiles of the distributions of the median values.
RESULTS: Results from 3253 CT examinations were obtained. The exposure levels observed were much lower than for the previous surveys (2007-2008 and 2010-2013) and among the lowest values currently published. A good homogeneity between facilities was also observed. New DRLs are proposed for each procedure and age group.
CONCLUSIONS: This new survey contributes to the continuing optimisation process in French paediatric CT practice. Its results have been recently used to update the national paediatric CT DRLs. KEY POINTS: • New national diagnostic reference levels (DRLs) are proposed for several paediatric CT procedures. • The DRLs proposed for brain, chest and abdomen-pelvis procedures are among the lowest published worldwide.

Entities:  

Keywords:  Multidetector computed tomography; Paediatrics; Radiation exposure; Radiation protection

Mesh:

Year:  2019        PMID: 31486877     DOI: 10.1007/s00330-019-06405-3

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  19 in total

1.  Nationwide survey of radiation exposure during pediatric computed tomography examinations and proposal of age-based diagnostic reference levels for Japan.

Authors:  Yasutaka Takei; Osamu Miyazaki; Kosuke Matsubara; Yoshiya Shimada; Yoshihisa Muramatsu; Keiichi Akahane; Keisuke Fujii; Shoichi Suzuki; Kichiro Koshida
Journal:  Pediatr Radiol       Date:  2016-02

2.  Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

Authors:  F Gay; Y Pavia; N Pierrat; S Lasalle; S Neuenschwander; H J Brisse
Journal:  Eur Radiol       Date:  2013-08-31       Impact factor: 5.315

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  [CT exposure from pediatric MDCT: results from the 2007-2008 SFIPP/ISRN survey].

Authors:  H J Brisse; B Aubert
Journal:  J Radiol       Date:  2009-02

5.  Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method.

Authors:  Karen E Thomas; Bo Wang
Journal:  Pediatr Radiol       Date:  2008-04-08

6.  X-ray beam filtration, dosimetry phantom size and CT patient dose conversion factors.

Authors:  Walter Huda; Alexander Sterzik; Sameer Tipnis
Journal:  Phys Med Biol       Date:  2009-12-21       Impact factor: 3.609

7.  A study to establish international diagnostic reference levels for paediatric computed tomography.

Authors:  J Vassileva; M Rehani; D Kostova-Lefterova; H M Al-Naemi; J S Al Suwaidi; D Arandjic; E H O Bashier; S Kodlulovich Renha; L El-Nachef; J G Aguilar; V Gershan; E Gershkevitsh; E Gruppetta; A Hustuc; A Jauhari; Mohammad Hassan Kharita; N Khelassi-Toutaoui; H R Khosravi; H Khoury; I Kralik; S Mahere; J Mazuoliene; P Mora; W Muhogora; P Muthuvelu; D Nikodemova; L Novak; A Pallewatte; D Pekarovič; M Shaaban; E Shelly; K Stepanyan; N Thelsy; P Visrutaratna; A Zaman
Journal:  Radiat Prot Dosimetry       Date:  2015-04-01       Impact factor: 0.972

8.  Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children.

Authors:  Haesung Yoon; Myung-Joon Kim; Choon-Sik Yoon; Jiin Choi; Hyun Joo Shin; Hyun Gi Kim; Mi-Jung Lee
Journal:  Pediatr Radiol       Date:  2014-09-26

9.  ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging.

Authors:  E Vañó; D L Miller; C J Martin; M M Rehani; K Kang; M Rosenstein; P Ortiz-López; S Mattsson; R Padovani; A Rogers
Journal:  Ann ICRP       Date:  2017-10

10.  Assessment of organ absorbed doses and estimation of effective doses from pediatric anthropomorphic phantom measurements for multi-detector row CT with and without automatic exposure control.

Authors:  Hervé J Brisse; Magalie Robilliard; Alexia Savignoni; Noelle Pierrat; Geneviève Gaboriaud; Yann De Rycke; Sylvia Neuenschwander; Bernard Aubert; Jean-Claude Rosenwald
Journal:  Health Phys       Date:  2009-10       Impact factor: 1.316

View more
  6 in total

1.  Diagnostic reference levels for chest computed tomography in children as a function of patient size.

Authors:  Denise Bos; Sebastian Zensen; Marcel K Opitz; Johannes Haubold; Kai Nassenstein; Sonja Kinner; Bernd Schweiger; Michael Forsting; Axel Wetter; Nika Guberina
Journal:  Pediatr Radiol       Date:  2022-04-05

2.  Pediatric minor head injury imaging practices: results from an ESPR survey.

Authors:  Maria I Argyropoulou; George A Alexiou; Vassileios G Xydis; Catherine Adamsbaum; Jean-Francois Chateil; Andrea Rossi; Nadine Girard; Élida Vázquez; Loukas G Astrakas
Journal:  Neuroradiology       Date:  2019-12-11       Impact factor: 2.804

3.  Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 2: plain radiography and diagnostic fluoroscopy.

Authors:  David Célier; Patrice Roch; Cécile Etard; Hubert Ducou Le Pointe; Hervé J Brisse
Journal:  Eur Radiol       Date:  2019-09-16       Impact factor: 5.315

4.  Paediatric diagnostic reference levels for common radiological examinations using the European guidelines.

Authors:  Anja Almén; Jónína Guðjónsdóttir; Nils Heimland; Britta Højgaard; Hanne Waltenburg; Anders Widmark
Journal:  Br J Radiol       Date:  2021-12-13       Impact factor: 3.039

5.  Radiation Dose Management in Pediatric Brain CT According to Age and Weight as Continuous Variables.

Authors:  Yusuke Inoue; Hiroyasu Itoh; Anri Waga; Ryosuke Sasa; Kohei Mitsui
Journal:  Tomography       Date:  2022-04-01

6.  Pragmatic Approaches to Reducing Radiation Dose in Brain Computed Tomography Scan using Scan Parameter Modification.

Authors:  Mohammad Reza Choopani; Iraj Abedi; Fatemeh Dalvand
Journal:  J Med Signals Sens       Date:  2022-07-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.