[CT exposure from pediatric MDCT: results from the 2007-2008 SFIPP/ISRN survey].

H J Brisse1, B Aubert.   

Abstract

PURPOSE: To evaluate current exposure levels from pediatric MDCT examinations in order to issue recommendations for the routine clinical practice that may be used for establishing future diagnostic reference levels (DRL). Materials and methods. A survey was conducted at hospital sites affiliated with the SFIPP (Société Francophone d'Imagerie Pédiatrique et Prénatale). Tube potential and volume computed tomography dose index (CTDI) vol. values were obtained for three age groups (1, 5 and 10 years) for typical scanning indications of eight anatomical regions.
RESULTS: Twenty of 29 sites provided us with a copy of their protocols. All ages groups combined, 97% of protocols used a tension level < or =120 kVp. For age groups 1, 5 and 10 years respectively, the 75th percentiles of dose distributions were: 31, 39.5 and 49.5 mGy for the "head" protocol; 24, 22 and 24 mGy for "head and neck"; 11, 11, and 11 mGy for "paranasal sinuses"; 46, 71 and 87 mGy for "petrous bone"; 3, 3.5 and 5.5 mGy for "chest"; 2, 3 and 4 mGy for "low dose lung"; 4, 4.5 and 7 mGy for "abdomen-pelvis"; 7, 11 and 12 mGy for "bone". The inter-center discrepancy for doses were still high.
CONCLUSION: This study provided an evaluation of current practices in reference centers for pediatric imaging and allowed readjustment of MDCT dose recommendations. It could help in the development of DRLS for pediatric MDCT.

Mesh:

Year:  2009        PMID: 19308005     DOI: 10.1016/s0221-0363(09)72471-0

Source DB:  PubMed          Journal:  J Radiol        ISSN: 0221-0363


  22 in total

Review 1.  First and second branchial arch syndromes: multimodality approach.

Authors:  Elodie Senggen; Tarek Laswed; Jean-Yves Meuwly; Leonor Alamo Maestre; Bertrand Jaques; Reto Meuli; François Gudinchet
Journal:  Pediatr Radiol       Date:  2010-10-06

2.  Nationwide survey of radiation exposure during pediatric computed tomography examinations and proposal of age-based diagnostic reference levels for Japan.

Authors:  Yasutaka Takei; Osamu Miyazaki; Kosuke Matsubara; Yoshiya Shimada; Yoshihisa Muramatsu; Keiichi Akahane; Keisuke Fujii; Shoichi Suzuki; Kichiro Koshida
Journal:  Pediatr Radiol       Date:  2016-02

3.  Paediatric CT reference doses based on weight and CT dosimetry phantom size: local experience using a 64-slice CT scanner.

Authors:  Debbie J Watson; Kerry S Coakley
Journal:  Pediatr Radiol       Date:  2010-01-13

Review 4.  CT utilization--trends and developments beyond the United States' borders.

Authors:  Karen E Thomas
Journal:  Pediatr Radiol       Date:  2011-08-17

5.  Radiation Doses in Consecutive CT Examinations from Five University of California Medical Centers.

Authors:  Rebecca Smith-Bindman; Michelle Moghadassi; Nicole Wilson; Thomas R Nelson; John M Boone; Christopher H Cagnon; Robert Gould; David J Hall; Mayil Krishnam; Ramit Lamba; Michael McNitt-Gray; Anthony Seibert; Diana L Miglioretti
Journal:  Radiology       Date:  2015-05-19       Impact factor: 11.105

6.  Paediatric CT dose: a multicentre audit of subspecialty practice in Australia and New Zealand.

Authors:  D Jackson; K Atkin; F Bettenay; J Clark; M R Ditchfield; J E Grimm; R Linke; G Long; E Onikul; J Pereira; M Phillips; F Wilson; E Paul; S K Goergen
Journal:  Eur Radiol       Date:  2015-06-03       Impact factor: 5.315

7.  IAEA survey of paediatric computed tomography practice in 40 countries in Asia, Europe, Latin America and Africa: procedures and protocols.

Authors:  Jenia Vassileva; Madan M Rehani; Kimberly Applegate; Nada A Ahmed; Humoud Al-Dhuhli; Huda M Al-Naemi; Jamila Salem Al Suwaidi; Danijela Arandjic; Adnan Beganovic; Tony Benavente; Simone Dias; Leila El-Nachef; Dario Faj; Mirtha E Gamarra-Sánchez; Juan Garcia Aguilar; Vesna Gershan; Eduard Gershkevitsh; Edward Gruppetta; Alexandru Hustuc; Sonja Ivanovic; Arif Jauhari; Mohammad Hassan Kharita; Siarhei Kharuzhyk; Nadia Khelassi-Toutaoui; Hamid Reza Khosravi; Desislava Kostova-Lefterova; Ivana Kralik; Lantao Liu; Jolanta Mazuoliene; Patricia Mora; Wilbroad Muhogora; Pirunthavany Muthuvelu; Denisa Nikodemova; Leos Novak; Aruna S Pallewatte; Mohamed Shaaban; Esti Shelly; Karapet Stepanyan; Eu-Leong Harvey J Teo; Naw Thelsy; Pannee Visrutaratna; Areesha Zaman; Dejan Zontar
Journal:  Eur Radiol       Date:  2012-09-01       Impact factor: 5.315

8.  Size-based quality-informed framework for quantitative optimization of pediatric CT.

Authors:  Ehsan Samei; Xiang Li; Donald P Frush
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-21

9.  Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 1: computed tomography.

Authors:  David Célier; Patrice Roch; Cécile Etard; Hubert Ducou Le Pointe; Hervé J Brisse
Journal:  Eur Radiol       Date:  2019-09-05       Impact factor: 5.315

Review 10.  Multidetector CT in children: current concepts and dose reduction strategies.

Authors:  Rutger A J Nievelstein; Ingrid M van Dam; Aart J van der Molen
Journal:  Pediatr Radiol       Date:  2010-06-10