Literature DB >> 31529249

Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 2: plain radiography and diagnostic fluoroscopy.

David Célier1, Patrice Roch2, Cécile Etard2, Hubert Ducou Le Pointe3,4,5, Hervé J Brisse5,6,7.   

Abstract

OBJECTIVES: To report on a dose survey conducted by the French societies of radiology and paediatric imaging (SFR and SFIPP) and the French public service expert in nuclear and radiological risks (IRSN), and to suggest new diagnostic reference levels (DRLs) for paediatric plain radiography and diagnostic fluoroscopy.
METHODS: Dose reports concerning four radiography procedures and three diagnostic fluoroscopy procedures performed in 2015-2016 on children aged 0-15 years were collected from 16 imaging departments on a voluntary basis. Air kerma-area product (PKA) was recorded for at least 10 patients per procedure, per centre and per age group. New DRLs were calculated as the 3rd quartiles of the distributions of the median values.
RESULTS: Results from 2249 radiography examinations and 1235 diagnostic fluoroscopy procedures were obtained. A noticeable variability in patient exposure between facilities was observed in diagnostic fluoroscopy and to a lesser extent in plain radiography. DRLs are proposed for each procedure and each age group.
CONCLUSIONS: This study showed that the applicable national DRLs in plain radiography were obsolete and its results have been recently used by the French authorities to update them. In diagnostic fluoroscopy, large differences of doses were observed, even among departments accustomed to paediatric procedures. The new national DRLs will be useful for optimising diagnostic practice. KEY POINTS: • New national diagnostic reference levels (DRLs) are proposed for several paediatric procedures in plain radiography and diagnostic fluoroscopy. • Even between departments accustomed to paediatric procedures, substantial differences of practice were observed, especially in diagnostic fluoroscopy.

Entities:  

Keywords:  Fluoroscopy; Paediatrics; Radiation exposure; Radiation protection; Radiography

Mesh:

Year:  2019        PMID: 31529249     DOI: 10.1007/s00330-019-06406-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  13 in total

1.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

Review 2.  Limitations of diagnostic reference level (DRL) and introduction of acceptable quality dose (AQD).

Authors:  M M Rehani
Journal:  Br J Radiol       Date:  2015-01       Impact factor: 3.039

3.  EOS Micro-dose Protocol: First Full-spine Radiation Dose Measurements in Anthropomorphic Phantoms and Comparisons with EOS Standard-dose and Conventional Digital Radiology.

Authors:  Peter Heide Pedersen; Asger Greval Petersen; Svend Erik Østgaard; Torben Tvedebrink; Søren P Eiskjær
Journal:  Spine (Phila Pa 1976)       Date:  2018-11-15       Impact factor: 3.468

4.  Cumulative Radiation Exposure With EOS Imaging Compared With Standard Spine Radiographs.

Authors:  T David Luo; Anthony A Stans; Beth A Schueler; A Noelle Larson
Journal:  Spine Deform       Date:  2015-03-04

5.  Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 1: computed tomography.

Authors:  David Célier; Patrice Roch; Cécile Etard; Hubert Ducou Le Pointe; Hervé J Brisse
Journal:  Eur Radiol       Date:  2019-09-05       Impact factor: 5.315

6.  Using diagnostic reference levels to evaluate the improvement of patient dose optimisation and the influence of recent technologies in radiography and computed tomography.

Authors:  Patrice Roch; David Célier; Cécile Dessaud; Cécile Etard
Journal:  Eur J Radiol       Date:  2017-11-07       Impact factor: 3.528

7.  ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging.

Authors:  E Vañó; D L Miller; C J Martin; M M Rehani; K Kang; M Rosenstein; P Ortiz-López; S Mattsson; R Padovani; A Rogers
Journal:  Ann ICRP       Date:  2017-10

8.  Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography.

Authors:  Tobias J Dietrich; Christian W A Pfirrmann; Alexander Schwab; Katja Pankalla; Florian M Buck
Journal:  Skeletal Radiol       Date:  2013-03-28       Impact factor: 2.199

9.  Diagnostic reference levels in pediatric radiology in Austria.

Authors:  Jochen Billinger; Robert Nowotny; Peter Homolka
Journal:  Eur Radiol       Date:  2010-01-22       Impact factor: 5.315

10.  Evaluation of cumulative effective dose and cancer risk from repetitive full spine imaging using EOS system: Impact to adolescent patients of different populations.

Authors:  Martin Law; Wang-Kei Ma; Eva Chan; Damian Lau; Candy Mui; Kenneth Cheung; Lawrance Yip; Wendy Lam
Journal:  Eur J Radiol       Date:  2017-09-11       Impact factor: 3.528

View more
  2 in total

1.  Use of weight-based vs age-based groupings in the study of typical values of air kerma area product (PKA) for paediatric radiographs of chest and abdomen.

Authors:  Ioannis Delakis; Charlotte Kelly
Journal:  Br J Radiol       Date:  2021-09-19       Impact factor: 3.039

2.  Paediatric diagnostic reference levels for common radiological examinations using the European guidelines.

Authors:  Anja Almén; Jónína Guðjónsdóttir; Nils Heimland; Britta Højgaard; Hanne Waltenburg; Anders Widmark
Journal:  Br J Radiol       Date:  2021-12-13       Impact factor: 3.039

  2 in total