Literature DB >> 20023330

X-ray beam filtration, dosimetry phantom size and CT patient dose conversion factors.

Walter Huda1, Alexander Sterzik, Sameer Tipnis.   

Abstract

We examine how the choice of CT x-ray beam filtration and phantom size influences patient dose (D) to computed tomography dose index (CTDI) conversion factors (i.e. D/CTDI). The ratio of head to body phantom CTDI(w) for a defined scan technique is alpha, and the ratio of organ dose when the body filter is changed to the head filter is beta. CTDI and organ doses were obtained using the ImPACT CT patient dosimetry calculator, and values of alpha and beta were determined for 39 CT scanners. The average value of alpha for the 39 CT scanners covering a 20 year period was 1.99 +/- 0.23, but 30% of scanners had alpha values that differed by more than 10% from the average. For GE, the value of alpha has been approximately constant at approximately 2.0. Both Philips and Siemens show a definite upward trend from values well below 2.0 in the early 1990s to well over 2.0 for their latest models. The data for Toshiba show no overall trend with time with half the data points below 2.0 and the remainder above this value. The average value of beta was 1.09 +/- 0.25. All vendors showed a downward trend in the beta parameter, and where the most recent scanners from each vendor had a beta value close to unity. Our results show that average D/CTDI conversion factors for a body phantom/filter combination are typically double those appropriate for a head phantom/filter combination.

Entities:  

Mesh:

Year:  2009        PMID: 20023330     DOI: 10.1088/0031-9155/55/2/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  IAEA survey of paediatric computed tomography practice in 40 countries in Asia, Europe, Latin America and Africa: procedures and protocols.

Authors:  Jenia Vassileva; Madan M Rehani; Kimberly Applegate; Nada A Ahmed; Humoud Al-Dhuhli; Huda M Al-Naemi; Jamila Salem Al Suwaidi; Danijela Arandjic; Adnan Beganovic; Tony Benavente; Simone Dias; Leila El-Nachef; Dario Faj; Mirtha E Gamarra-Sánchez; Juan Garcia Aguilar; Vesna Gershan; Eduard Gershkevitsh; Edward Gruppetta; Alexandru Hustuc; Sonja Ivanovic; Arif Jauhari; Mohammad Hassan Kharita; Siarhei Kharuzhyk; Nadia Khelassi-Toutaoui; Hamid Reza Khosravi; Desislava Kostova-Lefterova; Ivana Kralik; Lantao Liu; Jolanta Mazuoliene; Patricia Mora; Wilbroad Muhogora; Pirunthavany Muthuvelu; Denisa Nikodemova; Leos Novak; Aruna S Pallewatte; Mohamed Shaaban; Esti Shelly; Karapet Stepanyan; Eu-Leong Harvey J Teo; Naw Thelsy; Pannee Visrutaratna; Areesha Zaman; Dejan Zontar
Journal:  Eur Radiol       Date:  2012-09-01       Impact factor: 5.315

2.  Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 1: computed tomography.

Authors:  David Célier; Patrice Roch; Cécile Etard; Hubert Ducou Le Pointe; Hervé J Brisse
Journal:  Eur Radiol       Date:  2019-09-05       Impact factor: 5.315

3.  Assessment of paediatric CT dose indicators for the purpose of optimisation.

Authors:  Z Brady; F Ramanauskas; T M Cain; P N Johnston
Journal:  Br J Radiol       Date:  2012-07-27       Impact factor: 3.039

4.  Effective radiation dose in computed tomographic angiography of the chest and diagnostic cardiac catheterization in pediatric patients.

Authors:  Timotheus G Watson; Eugene Mah; U Joseph Schoepf; Lydia King; Walter Huda; Anthony M Hlavacek
Journal:  Pediatr Cardiol       Date:  2012-09-06       Impact factor: 1.655

  4 in total