Literature DB >> 29065694

ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging.

E Vañó, D L Miller, C J Martin, M M Rehani, K Kang, M Rosenstein, P Ortiz-López, S Mattsson, R Padovani, A Rogers.   

Abstract

Abstract –: The International Commission on Radiological Protection (ICRP) first introduced the term ‘diagnostic reference level’ (DRL) in 1996 in Publication 73. The concept was subsequently developed further, and practical guidance was provided in 2001. The DRL has been proven to be an effective tool that aids in optimisation of protection in the medical exposure of patients for diagnostic and interventional procedures. However, with time, it has become evident that additional advice is needed. There are issues related to definitions of the terms used in previous guidance, determination of the values for DRLs, the appropriate interval for re-evaluating and updating these values, appropriate use of DRLs in clinical practice, methods for practical application of DRLs, and application of the DRL concept to newer imaging technologies. This publication is intended as a further source of information and guidance on these issues. Some terminology has been clarified. In addition, this publication recommends quantities for use as DRLs for various imaging modalities, and provides information on the use of DRLs for interventional procedures and in paediatric imaging. It suggests modifications in the conduct of DRL surveys that take advantage of automated reporting of radiation-dose-related quantities, and highlights the importance of including information on DRLs in training programmes for healthcare workers. The target audience for this publication is national, regional, and local authorities; professional societies; and facilities that use ionising radiation for medical purposes, and responsible staff within these facilities. A full set of the Commission’s recommendations is provided.

Entities:  

Mesh:

Year:  2017        PMID: 29065694     DOI: 10.1177/0146645317717209

Source DB:  PubMed          Journal:  Ann ICRP        ISSN: 0146-6453


  74 in total

1.  CT diagnostic reference levels: are they appropriately computed?

Authors:  Thibault Vanaudenhove; Alain Van Muylem; Nigel Howarth; Pierre Alain Gevenois; Denis Tack
Journal:  Eur Radiol       Date:  2019-04-08       Impact factor: 5.315

2.  Estimation of the radiation dose in pregnancy: an automated patient-specific model using convolutional neural networks.

Authors:  Tianwu Xie; Habib Zaidi
Journal:  Eur Radiol       Date:  2019-06-21       Impact factor: 5.315

3.  Monitoring neurointerventional radiation doses using dose-tracking software: implications for the establishment of local diagnostic reference levels.

Authors:  Holly Acton; Karl James; Richard G Kavanagh; Colm O'Tuathaigh; Deirdre Moloney; Gerald Wyse; Noel Fanning; Michael Maher; Owen J O'Connor
Journal:  Eur Radiol       Date:  2018-04-12       Impact factor: 5.315

4.  X-ray examination dose surveys: how accurate are my results?

Authors:  Stephen Taylor; Alain Van Muylem; Nigel Howarth; Pierre Alain Gevenois; Denis Tack
Journal:  Eur Radiol       Date:  2019-03-15       Impact factor: 5.315

5.  Statistical analysis for obtaining optimum number of CT scanners in patient dose surveys for determining national diagnostic reference levels.

Authors:  Mehdi Sohrabi; Masoumeh Parsi; Sanaz Hariri Tabrizi
Journal:  Eur Radiol       Date:  2018-06-28       Impact factor: 5.315

6.  The associated factors for radiation dose variation in cardiac CT angiography.

Authors:  Ali B Alhailiy; Ernest U Ekpo; Peter L Kench; Elaine A Ryan; Patrick C Brennan; Mark McEntee
Journal:  Br J Radiol       Date:  2019-01-31       Impact factor: 3.039

Review 7.  Use of radiation dose index monitoring software in a multicenter environment for CT dose optimization.

Authors:  Lucia Riccardi; Francesca De Monte; Fabiola Cretti; Silvia Pini; Sergio Zucca; Maria Grazia Quattrocchi; Daniela Origgi; Antonella Del Vecchio; Carlo Giordano; Piergiorgio Marini; Francesco Lisciandro; Edoardo Trevisiol; Daniele Zefiro; Claudia Cutaia; Loredana D'Ercole; Michele Gabusi; Alessandro Scaggion; Marta Paiusco
Journal:  Radiol Med       Date:  2018-08-09       Impact factor: 3.469

8.  Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman.

Authors:  Ibrahim I Suliman
Journal:  J Digit Imaging       Date:  2020-02       Impact factor: 4.056

9.  Patient dose reference levels in surgery: a multicenter study.

Authors:  J Greffier; C Etard; O Mares; F Pereira; D Defez; C Duverger; P Branchereau; J P Beregi; R Coulomb; A Larbi
Journal:  Eur Radiol       Date:  2018-08-01       Impact factor: 5.315

10.  Patient-Based Dose Audit for Common Radiographic Examinations With Digital Radiology Systems: A Retrospective Cross-Sectional Study.

Authors:  Khalid M Alshamrani; Abdulkader A Alkenawi; Bushra N Alghamdi; Rawan H Honain; Haneen A Alshehri; Marwah O Alshatiri; Noor Mail; Ahmed Subahi; Shaza S Alsharif; Abdulaziz A Qurashi; Shrooq Aldahery; Reham Kaifi
Journal:  Cureus       Date:  2021-05-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.