Literature DB >> 31448208

Low dose cone-beam computed tomography reconstruction via hybrid prior contour based total variation regularization (hybrid-PCTV).

Yingxuan Chen1, Fang-Fang Yin1,2,3, Yawei Zhang2, You Zhang1, Lei Ren1,2.   

Abstract

BACKGROUND: Previously, we developed a prior contour based total variation (PCTV) method to use edge information derived from prior images for edge enhancement in low-dose cone-beam computed tomography (CBCT) reconstruction. However, the accuracy of edge enhancement in PCTV is affected by the deformable registration errors and anatomical changes from prior to on-board images. In this study, we develop a hybrid-PCTV method to address this limitation to enhance the robustness and accuracy of the PCTV method.
METHODS: Planning-CT is used as prior images and deformably registered with on-board CBCT reconstructed by the edge preserving TV (EPTV) method. Edges derived from planning CT are deformed based on the registered deformation vector fields to generate on-board edges for edge enhancement in PCTV reconstruction. Reference CBCT is reconstructed from the simulated projections of the deformed planning-CT. Image similarity map is then calculated between reference and on-board CBCT using structural similarity index (SSIM) method to estimate local registration accuracy. The hybrid-PCTV method enhances the edge information based on a weighted edge map that combines edges from both PCTV and EPTV methods. Higher weighting is given to PCTV edges at regions with high registration accuracy and to EPTV edges at regions with low registration accuracy. The hybrid-PCTV method was evaluated using both digital extended-cardiac-torso (XCAT) phantom and lung patient data. In XCAT study, breathing amplitude change, tumor shrinkage and new tumor were simulated from CT to CBCT. In the patient study, both simulated and real projections of lung patients were used for reconstruction. Results were compared with both EPTV and PCTV methods.
RESULTS: EPTV led to blurring bony structures due to missing edge information, and PCTV led to blurring tumor edges due to inaccurate edge information caused by errors in the deformable registration. In contrast, hybrid-PCTV enhanced edges of both bone and tumor. In XCAT study using 30 half-fan CBCT projections, compared with ground truth, relative errors (REs) were 1.3%, 1.1% and 0.9% and edge cross-correlation were 0.66, 0.68 and 0.71 for EPTV, PCTV and hybrid-PCTV, respectively. Moreover, in the lung patient data, hybrid-PCTV avoided the wrong edge enhancement in the PCTV method while maintaining enhancements of the correct edges.
CONCLUSIONS: Hybrid-PCTV further improved the robustness and accuracy of PCTV by accounting for uncertainties in deformable registration and anatomical changes between prior and onboard images. The accurate edge enhancement in hybrid-PCTV will be valuable for target localization in radiation therapy.

Entities:  

Keywords:  Cone-beam computed tomography (CBCT); low dose reconstruction; total variation

Year:  2019        PMID: 31448208      PMCID: PMC6685814          DOI: 10.21037/qims.2019.06.02

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  33 in total

1.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

2.  GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation.

Authors:  Xun Jia; Yifei Lou; Ruijiang Li; William Y Song; Steve B Jiang
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

3.  Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT).

Authors:  Jian-Yue Jin; Lei Ren; Qiang Liu; Jinkoo Kim; Ning Wen; Huaiqun Guan; Benjamin Movsas; Indrin J Chetty
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

4.  Evaluation of radiation dose and image quality for the Varian cone beam computed tomography system.

Authors:  Harry C Y Cheng; Vincent W C Wu; Eva S F Liu; Dora L W Kwong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-05-01       Impact factor: 7.038

5.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.

Authors:  Guang-Hong Chen; Jie Tang; Shuai Leng
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

6.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

7.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

Authors:  Paul J Keall; Gig S Mageras; James M Balter; Richard S Emery; Kenneth M Forster; Steve B Jiang; Jeffrey M Kapatoes; Daniel A Low; Martin J Murphy; Brad R Murray; Chester R Ramsey; Marcel B Van Herk; S Sastry Vedam; John W Wong; Ellen Yorke
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

8.  The diaphragm as an anatomic surrogate for lung tumor motion.

Authors:  Laura I Cerviño; Alvin K Y Chao; Ajay Sandhu; Steve B Jiang
Journal:  Phys Med Biol       Date:  2009-05-15       Impact factor: 3.609

9.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.

Authors:  Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2008-08-13       Impact factor: 3.609

10.  Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT.

Authors:  Jiayu Song; Qing H Liu; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

View more
  4 in total

1.  Patient-specific deep learning model to enhance 4D-CBCT image for radiomics analysis.

Authors:  Zeyu Zhang; Mi Huang; Zhuoran Jiang; Yushi Chang; Ke Lu; Fang-Fang Yin; Phuoc Tran; Dapeng Wu; Chris Beltran; Lei Ren
Journal:  Phys Med Biol       Date:  2022-04-01       Impact factor: 4.174

2.  Improving deformable image registration with point metric and masking technique for postoperative breast cancer radiotherapy.

Authors:  Xin Xie; Yuchun Song; Feng Ye; Hui Yan; Shulian Wang; Xinming Zhao; Jianrong Dai
Journal:  Quant Imaging Med Surg       Date:  2021-04

3.  LCPR-Net: low-count PET image reconstruction using the domain transform and cycle-consistent generative adversarial networks.

Authors:  Hengzhi Xue; Qiyang Zhang; Sijuan Zou; Weiguang Zhang; Chao Zhou; Changjun Tie; Qian Wan; Yueyang Teng; Yongchang Li; Dong Liang; Xin Liu; Yongfeng Yang; Hairong Zheng; Xiaohua Zhu; Zhanli Hu
Journal:  Quant Imaging Med Surg       Date:  2021-02

4.  4D radiomics: impact of 4D-CBCT image quality on radiomic analysis.

Authors:  Zeyu Zhang; Mi Huang; Zhuoran Jiang; Yushi Chang; Jordan Torok; Fang-Fang Yin; Lei Ren
Journal:  Phys Med Biol       Date:  2021-02-11       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.