Literature DB >> 20964209

4D XCAT phantom for multimodality imaging research.

W P Segars1, G Sturgeon, S Mendonca, Jason Grimes, B M W Tsui.   

Abstract

PURPOSE: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research.
METHODS: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, "Basic anatomical and physiological data for use in radiological protection: reference values," ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages.
RESULTS: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research.
CONCLUSIONS: With the ability to produce realistic, predictive 3D and 4D imaging data from populations of normal and abnormal patients under various imaging parameters, the authors conclude that the XCAT provides an important tool in imaging research to evaluate and improve imaging devices and techniques. In the field of x-ray CT, the phantom may also provide the necessary foundation with which to optimize clinical CT applications in terms of image quality versus radiation dose, an area of research that is becoming more significant with the growing use of CT.

Entities:  

Mesh:

Year:  2010        PMID: 20964209      PMCID: PMC2941518          DOI: 10.1118/1.3480985

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Analytic and iterative reconstruction algorithms in SPECT.

Authors:  Philippe P Bruyant
Journal:  J Nucl Med       Date:  2002-10       Impact factor: 10.057

2.  The SIMRI project: a versatile and interactive MRI simulator.

Authors:  H Benoit-Cattin; G Collewet; B Belaroussi; H Saint-Jalmes; C Odet
Journal:  J Magn Reson       Date:  2005-03       Impact factor: 2.229

3.  GATE: a simulation toolkit for PET and SPECT.

Authors:  S Jan; G Santin; D Strul; S Staelens; K Assié; D Autret; S Avner; R Barbier; M Bardiès; P M Bloomfield; D Brasse; V Breton; P Bruyndonckx; I Buvat; A F Chatziioannou; Y Choi; Y H Chung; C Comtat; D Donnarieix; L Ferrer; S J Glick; C J Groiselle; D Guez; P F Honore; S Kerhoas-Cavata; A S Kirov; V Kohli; M Koole; M Krieguer; D J van der Laan; F Lamare; G Largeron; C Lartizien; D Lazaro; M C Maas; L Maigne; F Mayet; F Melot; C Merheb; E Pennacchio; J Perez; U Pietrzyk; F R Rannou; M Rey; D R Schaart; C R Schmidtlein; L Simon; T Y Song; J M Vieira; D Visvikis; R Van de Walle; E Wieërs; C Morel
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

4.  Deformable models with parameter functions for cardiac motion analysis from tagged MRI data.

Authors:  J Park; D Metaxas; A A Young; L Axel
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

5.  Methodology for generating a 3D computerized breast phantom from empirical data.

Authors:  Christina M Li; W Paul Segars; Georgia D Tourassi; John M Boone; James T Dobbins
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

6.  Normal and pathological NCAT image and phantom data based on physiologically realistic left ventricle finite-element models.

Authors:  Alexander I Veress; W Paul Segars; Jeffrey A Weiss; Benjamin M W Tsui; Grant T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2006-12       Impact factor: 10.048

7.  Patient-specific dose estimation for pediatric chest CT.

Authors:  Xiang Li; Ehsan Samei; W Paul Segars; Gregory M Sturgeon; James G Colsher; Donald P Frush
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

8.  The UF family of reference hybrid phantoms for computational radiation dosimetry.

Authors:  Choonsik Lee; Daniel Lodwick; Jorge Hurtado; Deanna Pafundi; Jonathan L Williams; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2009-12-17       Impact factor: 3.609

Review 9.  Voxel-based computational models of real human anatomy: a review.

Authors:  Martin Caon
Journal:  Radiat Environ Biophys       Date:  2004-01-17       Impact factor: 1.925

10.  Realistic CT simulation using the 4D XCAT phantom.

Authors:  W P Segars; M Mahesh; T J Beck; E C Frey; B M W Tsui
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

View more
  238 in total

1.  Simulation Evaluation of Quantitative Myocardial Perfusion Assessment from Cardiac CT.

Authors:  Michael Bindschadler; Dimple Modgil; Kelley R Branch; Patrick J La Riviere; Adam M Alessio
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19

2.  Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: a feasibility study.

Authors:  Jing Cai; Zheng Chang; Zhiheng Wang; William Paul Segars; Fang-Fang Yin
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

3.  A novel technique for markerless, self-sorted 4D-CBCT: feasibility study.

Authors:  Irina Vergalasova; Jing Cai; Fang-Fang Yin
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

4.  Optimization of an on-board imaging system for extremely rapid radiation therapy.

Authors:  Erica M Cherry Kemmerling; Meng Wu; He Yang; Peter G Maxim; Billy W Loo; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

5.  The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization.

Authors:  W P Segars; Hannah Norris; Gregory M Sturgeon; Yakun Zhang; Jason Bond; Anum Minhas; Daniel J Tward; J T Ratnanather; M I Miller; D Frush; E Samei
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

6.  Analytical reconstructions of intensity modulated x-ray phase-contrast imaging of human scale phantoms.

Authors:  Bartłomiej Włodarczyk; Jakub Pietrzak
Journal:  Biomed Opt Express       Date:  2015-10-05       Impact factor: 3.732

7.  Population of 224 realistic human subject-based computational breast phantoms.

Authors:  David W Erickson; Jered R Wells; Gregory M Sturgeon; Ehsan Samei; James T Dobbins; W Paul Segars; Joseph Y Lo
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

8.  Realistic Simulation of Regional Myocardial Perfusion Defects for Cardiac SPECT Studies.

Authors:  George S K Fung; W Paul Segars; Taek-Soo Lee; Takahiro Higuchi; Alexander I Veress; Grant T Gullberg; Benjamin M W Tsui
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010 Oct-Nov

9.  Factors affecting the normality of channel outputs of channelized model observers: an investigation using realistic myocardial perfusion SPECT images.

Authors:  Fatma E A Elshahaby; Michael Ghaly; Abhinav K Jha; Eric C Frey
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-28

10.  Motion correction of respiratory-gated PET images using deep learning based image registration framework.

Authors:  Tiantian Li; Mengxi Zhang; Wenyuan Qi; Evren Asma; Jinyi Qi
Journal:  Phys Med Biol       Date:  2020-07-30       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.