Literature DB >> 19443952

The diaphragm as an anatomic surrogate for lung tumor motion.

Laura I Cerviño1, Alvin K Y Chao, Ajay Sandhu, Steve B Jiang.   

Abstract

Lung tumor motion due to respiration poses a challenge in the application of modern three-dimensional conformal radiotherapy. Direct tracking of the lung tumor during radiation therapy is very difficult without implanted fiducial markers. Indirect tracking relies on the correlation of the tumor's motion and the surrogate's motion. The present paper presents an analysis of the correlation between tumor motion and diaphragm motion in order to evaluate the potential use of diaphragm as a surrogate for tumor motion. We have analyzed the correlation between diaphragm motion and superior-inferior lung tumor motion in 32 fluoroscopic image sequences from ten lung cancer patients. A simple linear model and a more complex linear model that accounts for phase delays between the two motions have been used. Results show that the diaphragm is a good surrogate for tumor motion prediction for most patients, resulting in an average correlation factor of 0.94 and 0.98 with each model respectively. The model that accounts for delays leads to an average localization prediction error of 0.8 mm and an error at the 95% confidence level of 2.1 mm. However, for one patient studied, the correlation is much weaker compared to other patients. This indicates that, before using diaphragm for lung tumor prediction, the correlation should be examined on a patient-by-patient basis.

Entities:  

Mesh:

Year:  2009        PMID: 19443952     DOI: 10.1088/0031-9155/54/11/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  32 in total

1.  Accelerating volumetric cine MRI (VC-MRI) using undersampling for real-time 3D target localization/tracking in radiation therapy: a feasibility study.

Authors:  Wendy Harris; Fang-Fang Yin; Chunhao Wang; You Zhang; Jing Cai; Lei Ren
Journal:  Phys Med Biol       Date:  2017-12-14       Impact factor: 3.609

2.  A novel phantom for characterization of dual energy imaging using an on-board imaging system.

Authors:  Maksat Haytmyradov; Rakesh Patel; Hassan Mostafavi; Murat Surucu; Adam Wang; Matthew M Harkenrider; John C Roeske
Journal:  Phys Med Biol       Date:  2019-01-21       Impact factor: 3.609

3.  Mitigating errors in external respiratory surrogate-based models of tumor position.

Authors:  Kathleen T Malinowski; Thomas J McAvoy; Rohini George; Sonja Dieterich; Warren D D'Souza
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-04-01       Impact factor: 7.038

4.  Estimating 4D-CBCT from prior information and extremely limited angle projections using structural PCA and weighted free-form deformation for lung radiotherapy.

Authors:  Wendy Harris; You Zhang; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.071

5.  2D/4D marker-free tumor tracking using 4D CBCT as the reference image.

Authors:  Mengjiao Wang; Gregory C Sharp; Simon Rit; Vivien Delmon; Guangzhi Wang
Journal:  Phys Med Biol       Date:  2014-04-08       Impact factor: 3.609

6.  A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging.

Authors:  Wendy Harris; Lei Ren; Jing Cai; You Zhang; Zheng Chang; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-02-06       Impact factor: 7.038

7.  Unsupervised Learning for Robust Respiratory Signal Estimation From X-Ray Fluoroscopy.

Authors:  Peter Fischer; Thomas Pohl; Anthony Faranesh; Andreas Maier; Joachim Hornegger
Journal:  IEEE Trans Med Imaging       Date:  2016-09-16       Impact factor: 10.048

8.  Modeling the respiratory motion of solitary pulmonary nodules and determining the impact of respiratory motion on their detection in SPECT imaging.

Authors:  Mark S Smyczynski; Howard C Gifford; Andre Lehovich; Joseph E McNamara; W Paul Segars; Eric A Hoffman; Benjamin M W Tsui; Michael A King
Journal:  IEEE Trans Nucl Sci       Date:  2016-02-15       Impact factor: 1.679

9.  Characterization of optical-surface-imaging-based spirometry for respiratory surrogating in radiotherapy.

Authors:  Guang Li; Jie Wei; Hailiang Huang; Qing Chen; Carl P Gaebler; Tiffany Lin; Amy Yuan; Andreas Rimner; James Mechalakos
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

10.  Audiovisual biofeedback improves motion prediction accuracy.

Authors:  Sean Pollock; Danny Lee; Paul Keall; Taeho Kim
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.