Literature DB >> 21158275

Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT).

Jian-Yue Jin1, Lei Ren, Qiang Liu, Jinkoo Kim, Ning Wen, Huaiqun Guan, Benjamin Movsas, Indrin J Chetty.   

Abstract

PURPOSE: The authors propose a combined scatter reduction and correction method to improve image quality in cone-beam computed tomography (CBCT). Although using a beam-block approach similar to previous techniques to measure the scatter, this method differs in that the authors utilize partially blocked projection data obtained during scatter measurement for CBCT image reconstruction. This study aims to evaluate the feasibility of the proposed approach.
METHODS: A 1D grid, composed of lead septa, was placed between the radiation source and the imaging object for scatter measurement. Image data were collected from the grid interspace regions while the scatter distribution was measured in the blocked regions under the grid. Scatter correction was performed by subtracting the measured scatter from the imaging data. Image information in the penumbral regions of the grid was derived. Three imaging modes were developed to reconstruct full CBCT images from partial projection data. The single-rotation half-fan mode uses interpolation to fill the missing data. The dual-rotation half-fan mode uses two rotations, with the grid offset by half a grid cycle, to acquire two complementary sets of projections, which are then merged to form complete projections for reconstruction. The single-rotation full-fan mode was designed for imaging a small object or a region of interest. Full-fan projection images were acquired over a 360 degrees scan angle with the grid shifting a distance during the scan. An enlarged Catphan phantom was used to evaluate potential improvement in image quality with the proposed technique. An anthropomorphic pelvis phantom was used to validate the feasibility of reconstructing a complete set of CBCT images from the partially blocked projections using three imaging modes. Rigid-body image registration was performed between the CBCT images from the single-rotation half-fan mode and the simulation CT and the results were compared to that for the CBCT images from dual-rotation mode and conventional CBCT images.
RESULTS: The proposed technique reduced the streak artifact index from 58% to 1% in comparison with the conventional CBCT. It also improved CT number linearity from 0.880 to 0.998 and the contrast-to-noise ratio (CNR) from 4.29 to 6.42. Complete sets of CBCT images with overall improved image quality were achieved for all three image modes. The longitudinal resolution was slightly compromised for the single-rotation half-fan mode. High resolution was retained for the dual-rotation half-fan and single-rotation full-fan modes in the longitudinal direction. The registration error for the CBCT images from the single-rotation half-fan mode was 0.8 +/- 0.3 mm in the longitudinal direction and negligible in the other directions.
CONCLUSIONS: The proposed method provides combined scatter correction and direct scatter reduction. Scatter correction may eliminate scatter artifacts, while direct scatter reduction may improve the CNR to compensate the CNR degradation due to scatter correction. Complete sets of CBCT images are reconstructed in all three imaging modes. The single-rotation mode can be used for rigid-body patient alignment despite degradation in longitudinal resolution. The dual-rotation mode may be used to improve CBCT image quality for soft tissue delineation in adaptive radiation therapy.

Entities:  

Mesh:

Year:  2010        PMID: 21158275     DOI: 10.1118/1.3497272

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  An interprojection sensor fusion approach to estimate blocked projection signal in synchronized moving grid-based CBCT system.

Authors:  Hong Zhang; Lei Ren; Vic Kong; William Giles; You Zhang; Jian-Yue Jin
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

3.  X-ray scatter correction method for dedicated breast computed tomography.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

4.  An Inter-Projection Interpolation (IPI) Approach with Geometric Model Restriction to Reduce Image Dose in Cone Beam CT (CBCT).

Authors:  Hong Zhang; Fengchong Kong; Lei Ren; Jian-Yue Jin
Journal:  Comput Model Objects Present Images (2014)       Date:  2014-09

5.  Scatter Reduction and Correction for Dual-Source Cone-Beam CT Using Prepatient Grids.

Authors:  Lei Ren; Yingxuan Chen; You Zhang; William Giles; Jianyue Jin; Fang-Fang Yin
Journal:  Technol Cancer Res Treat       Date:  2015-05-24

6.  Validation of a deformable image registration technique for cone beam CT-based dose verification.

Authors:  M Moteabbed; G C Sharp; Y Wang; A Trofimov; J A Efstathiou; H-M Lu
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

7.  Single-scan patient-specific scatter correction in computed tomography using peripheral detection of scatter and compressed sensing scatter retrieval.

Authors:  Bowen Meng; Ho Lee; Lei Xing; Benjamin P Fahimian
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

Review 8.  Improving radiotherapy planning, delivery accuracy, and normal tissue sparing using cutting edge technologies.

Authors:  Carri K Glide-Hurst; Indrin J Chetty
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

9.  A model-based scatter artifacts correction for cone beam CT.

Authors:  Wei Zhao; Don Vernekohl; Jun Zhu; Luyao Wang; Lei Xing
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

10.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609

View more