| Literature DB >> 31300242 |
Hassan Hashemi1, Samira Heydarian2, Abbas Ali Yekta3, Mohamadreza Aghamirsalim4, Mahin Ahmadi-Pishkuhi1, Mehrnaz Valadkhan1, Hadi Ostadimoghaddam5, Ahmad Ahmadzadeh Amiri6, Mehdi Khabazkhoob7.
Abstract
OBJECTIVE: This study was conducted to evaluate the level of agreement in keratometry measurements between a rotating Scheimpflug imaging-based system (Pentacam) and a handheld auto-refractokeratometer (handheld NIDEK ARK-30).Entities:
Keywords: Auto-refractoqueratómetro portátil; Handheld auto-refractokeratometer; Keratometery; Pentacam; Queratómetro
Mesh:
Year: 2019 PMID: 31300242 PMCID: PMC6978591 DOI: 10.1016/j.optom.2019.06.001
Source DB: PubMed Journal: J Optom ISSN: 1989-1342
Mean, paired differences, Pearson's correlation coefficient (PCC) and 95%limmit of agreement(LOA) of Flat keratometry measured by the Auto Ref/Keratometer Nidek ARK-30 and Pentacam.
| Auto ref/keratometer | Pentacam | Paired differences | PCC | 95%LOA | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Mean ± SD | Mean ± SD | Mean ± SD | Lower | Upper | Width | |||||
| Total | 43.32 ± 1.51 | 43.06 ± 1.56 | −.26 ± 0.93 | <0.001 | 0.817 | <0.001 | −2.09 | 1.56 | 3.65 | |
| Age (years) | 6–20 | 43.01 ± 1.36 | 42.77 ± 1.36 | −.23 ± 0.56 | <0.001 | 0.915 | <0.001 | −1.33 | 0.86 | 2.19 |
| 21–30 | 43.16 ± 1.55 | 42.84 ± 1.51 | −.31 ± 0.95 | 0.003 | 0.806 | <0.001 | −2.18 | 1.56 | 3.74 | |
| 31–40 | 43.37 ± 1.50 | 43.18 ± 1.52 | −.18 ± 0.57 | <0.001 | 0.928 | <0.001 | −1.31 | 0.94 | 2.25 | |
| 41–50 | 43.72 ± 1.43 | 43.38 ± 1.64 | −.34 ± 0.99 | <0.001 | 0.802 | <0.001 | −2.25 | 1.62 | 3.88 | |
| 51–60 | 43.32 ± 1.85 | 43.49 ± 1.76 | .16 ± 0.62 | 0.102 | 0.941 | <0.001 | −1.05 | 1.39 | 2.45 | |
| 61–70 | 43.82 ± 1.56 | 43.53 ± 1.53 | −.29 ± 1.43 | 0.206 | 0.569 | <0.001 | −3.11 | 2.52 | 5.63 | |
| >70 | 43.76 ± 1.70 | 42.58 ± 2.21 | −1.17 ± 2.39 | 0.036 | 0.274 | 0.229 | −5.87 | 3.52 | 9.39 | |
| Refractive errors | Emmetropia | 43.23 ± 1.46 | 43.03 ± 1.46 | −.19 ± 0.64 | <0.001 | 0.904 | <0.001 | −1.45 | 1.05 | 2.51 |
| Myopia | 43.49 ± 1.53 | 43.15 ± 1.59 | −.34 ± 1.01 | <0.001 | 0.789 | <0.001 | −2.33 | 1.64 | 3.98 | |
| Hyperopia | 43.52 ± 1.67 | 43.06 ± 1.94 | −.46 ± 1.62 | 0.010 | 0.606 | <0.001 | −3.64 | 2.72 | 6.37 | |
The P-value calculated by pair-t-test.
The P-value calculated for Pearson's correlation coefficient.
Figure 1Agreement between Nidek ARK-30 handheld auto-refractokeratometer and Pentacam for the measurements of the flat (A) and steep (B) keratometry. The middle line indicates the mean difference and the two dashed side lines show the 95% limits of agreement.
Mean, paired differences, Pearson's correlation coefficient (PCC) and 95%limmit of agreement (LOA) of Steep keratometry measured by the Auto Ref/Keratometer Nidek ARK-30 and Pentacam.
| Auto ref/keratometer | Pentacam | Paired differences | PCC | 95%LOA | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Mean ± SD | Mean ± SD | Mean ± SD | Lower | Upper | Width | |||||
| Total | 44.12 ± 1.61 | 44.07 ± 1.67 | −.05 ± 0.75 | 0.093 | 0.894 | <0.001 | −1.53 | 1.43 | 2.96 | |
| Age (years) | 6–20 | 43.82 ± 1.45 | 43.72 ± 1.45 | −.09 ± 0.40 | 0.002 | 0.962 | <0.001 | −0.87 | 0.69 | 1.57 |
| 21–30 | 43.88 ± 1.64 | 43.86 ± 1.69 | −.01 ± 0.87 | 0.845 | 0.862 | <0.001 | −1.74 | 1.70 | 3.44 | |
| 31–40 | 44.29 ± 1.59 | 44.25 ± 1.66 | −.03 ± 0.68 | 0.535 | 0.914 | <0.001 | −1.37 | 1.29 | 2.66 | |
| 41–50 | 44.40 ± 1.52 | 44.26 ± 1.60 | −.14 ± 0.57 | 0.014 | 0.935 | <0.001 | −1.26 | 0.97 | 2.24 | |
| 51–60 | 44.34 ± 1.90 | 44.40 ± 1.97 | 0.06 ± 1.12 | 0.735 | 0.832 | <0.001 | −2.14 | 2.26 | 4.41 | |
| 61–70 | 44.54 ± 1.74 | 44.55 ± 1.89 | 0.00 ± 1.54 | 0.981 | 0.643 | <0.001 | −3.02 | 3.03 | 6.05 | |
| >70 | 44.47 ± 1.86 | 44.61 ± 2.11 | 0.13 ± 0.71 | 0.380 | 0.943 | <0.001 | −1.26 | 1.53 | 2.79 | |
| Refractive error | Emmetropia | 43.97 ± 1.52 | 43.93 ± 1.63 | −0.03 ± 0.66 | 0.248 | 0.913 | <0.001 | −1.34 | 1.26 | 2.61 |
| Myopia | 44.60 ± 1.65 | 44.44 ± 1.64 | −0.15 ± 0.82 | 0.046 | 0.875 | <0.001 | −1.76 | 1.45 | 3.26 | |
| Hyperopia | 44.17 ± 1.82 | 44.20 ± 1.80 | .02 ± 1.00 | 0.821 | 0.848 | <0.001 | −1.94 | 1.98 | 3.93 | |
The P-value calculated by pair-t-test.
The P-value calculated for Pearson's correlation coefficient.
The formula prediction between keratometry by Pentacam (Y) and Auto Ref/Keratometer Nidek ARK-30 (X1) and R square.
| Constant + B-Coefficients × (X1) | Constant + B-Coefficients × (X2) | ||||||
|---|---|---|---|---|---|---|---|
| Total | 9.29 + 0.79 × (X1) | 0.67 | <0.001 | 6.12 + 0.86 × (X2) | 0.80 | <0.001 | |
| Age (years) | 6–20 | 4.02 + 0.91 × (X1) | 0.84 | 0.002 | 1.78 + 0.96 × (X2) | 0.93 | 0.050 |
| 21–30 | 7.83 + 0.83 × (X1) | 0.65 | 0.007 | 7.11 + 0.84 × (X2) | 0.74 | 0.003 | |
| 31–40 | 3.92 + 0.91 × (X1) | 0.86 | 0.010 | 5.54 + 0.88 × (X2) | 0.84 | <0.001 | |
| 41–50 | 13.49 + 0.70 × (X1) | 0.64 | <0.001 | 5.09 + 0.89 × (X2) | 0.87 | <0.001 | |
| 51–60 | 0.40 + 0.98 × (X1) | 0.89 | 0.875 | 8.66 + 0.80 × (X2) | 0.69 | 0.033 | |
| 61–70 | 18.61 + 0.58 × (X1) | 0.32 | 0.004 | 18.14 + 0.59 × (X2) | 0.41 | <0.001 | |
| >70 | 34.74 + 0.21 × (X1) | 0.08 | <0.001 | 7.40 + 0.83 × (X2) | 0.89 | 0.023 | |
| Refractive error | Emmetropia | 4.26 + 0.91 × (X1) | 0.82 | <0.001 | 6.66 + 0.85 × (X2) | 0.83 | <0.001 |
| Myopia | 10.72 + 0.76 × (X1) | 0.62 | <0.001 | 5.53 + 0.88 × (X2) | 0.77 | 0.008 | |
| Hyperopia | 21.05 + 0.52 × (X1) | 0.37 | <0.001 | 6.42 + 0.85 × (X2) | 0.72 | 0.015 |
X1: flat keratometry by Pentacam.
X2: steep keratometry by Pentacam.