Literature DB >> 11826999

Corneal shape change during accommodation.

B K Pierścionek1, A Popiołek-Masajada, H Kasprzak.   

Abstract

PURPOSE: To investigate whether accommodation induces any changes in central corneal curvature.
METHODS: Shape changes were measured on 14 subjects using a keratometer modified to enable a change in focus to occur without a change in vergence. All subjects were emmetropic and their ages ranged from approximately 20 to 28 years.
RESULTS: In 11 of the 14 subjects a difference in central corneal curvature, of around 0.4 D in at least one principal meridian, was found when focus was changed between distant and near targets. In 9 subjects the curvature was greater for near focus in at least one meridian. In 5 subjects the change in one meridian was opposite in effect to what would be expected, i.e. the curvature was greater at distance than at near.
CONCLUSION: The study suggests that accommodation may have some effect on corneal shape.

Mesh:

Year:  2001        PMID: 11826999     DOI: 10.1038/eye.2001.246

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  5 in total

Review 1.  [PresbyLASIK: treatment approaches with the excimer laser].

Authors:  K A Becker; A Jaksche; F G Holz
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

2.  Corneal Curvature: the Influence of Corneal Accommodation and Biomechanics on Corneal Shape.

Authors:  Henry B Wallace; James McKelvie; Colin R Green; Stuti L Misra
Journal:  Transl Vis Sci Technol       Date:  2019-07-08       Impact factor: 3.283

3.  Agreement between Pentacam and handheld Auto-Refractor/Keratometer for keratometry measurement.

Authors:  Hassan Hashemi; Samira Heydarian; Abbas Ali Yekta; Mohamadreza Aghamirsalim; Mahin Ahmadi-Pishkuhi; Mehrnaz Valadkhan; Hadi Ostadimoghaddam; Ahmad Ahmadzadeh Amiri; Mehdi Khabazkhoob
Journal:  J Optom       Date:  2019-07-10

4.  Variations in intraocular pressure and visual parameters before and after using mobile virtual reality glasses and their effects on the eyes.

Authors:  Ching-Huang Lin; Hsien-Chang Lin; Chien-Yu Chen; Chong-Chung Lih
Journal:  Sci Rep       Date:  2022-02-24       Impact factor: 4.379

5.  Effect of Cycloplegia on Corneal Biometrics and Refractive State.

Authors:  Abbas Bagheri; Mohadeseh Feizi; Aliakbar Shafii; Amir Faramarzi; Mehdi Tavakoli; Shahin Yazdani
Journal:  J Ophthalmic Vis Res       Date:  2018 Apr-Jun
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.