Comparison of refractive outcomes using five devices for the assessment of preoperative corneal power.

Woong-Joo Whang1, Yong-Soo Byun, Choun-Ki Joo.   

Abstract

BACKGROUND: To compare keratometric values obtained with a manual keratometer (Topcon), an automated keratometer (Canon), an Orbscan II (Bausch & Lomb), the IOLMaster keratometer (Carl-Zeiss) and the Pentacam rotating Scheimpflug camera (Oculus) in cataract surgery, and to characterize the refractive outcomes generated using each device.
DESIGN: Retrospective study conducted at a tertiary university hospital. PARTICIPANTS: Sixty-nine eyes of 69 patients were analysed.
METHODS: The keratometric values obtained with different devices (manual keratometer, automated keratometer, corneal topography, IOLMaster keratometer and Scheimpflug camera) were employed for intraocular lens power calculation. Multiple comparisons of averaged keratometric value were conducted, and the averaged keratometric value was used to calculate the predicted refraction. The absolute values of corneal astigmatism were calculated and also compared. MAIN OUTCOME MEASURES: Mean keratometric value, absolute value of astigmatism, mean error and mean absolute error from each device.
RESULTS: The mean keratometric values generated by manual keratometer, automated keratometry, corneal topography, IOLMaster keratometer and the Pentacam Scheimpflug system were 43.95 ± 1.39, 43.91 ± 1.39, 44.67 ± 1.53, 44.03 ± 1.41 and 42.96 ± 1.39 diopter, respectively. The absolute value of astigmatism determined via manual keratometer, automated keratometer, corneal topography, IOLMaster keratometer and the Pentacam Scheimpflug system were 0.95 ± 0.60, 0.99 ± 0.69, 1.14 ± 0.74, 1.11 ± 0.65 and 1.03 ± 0.73 diopter, respectively. The corneal topography showed statistically significant differences with other devices and produced the greater value in mean absolute errors (all P < 0.05).
CONCLUSION: Keratometric values with standard devices are a good choice for cataract surgery, whereas the corneal topography is not an appropriate method for the assessment of preoperative keratometric values.
© 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Mesh:

Year:  2012        PMID: 22394318     DOI: 10.1111/j.1442-9071.2012.02777.x

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  8 in total

1.  Keratometry with five different techniques: a study of device repeatability and inter-device agreement.

Authors:  Shiva Mehravaran; Soheila Asgari; Sara Bigdeli; Ashkan Shahnazi; Hassan Hashemi
Journal:  Int Ophthalmol       Date:  2014-02-23       Impact factor: 2.031

2.  Comparison of 25 MHz and 50 MHz ultrasound biomicroscopy for imaging of the lens and its related diseases.

Authors:  Ming-Yu Shi; Xiao Han; Jin-Song Zhang; Qi-Chang Yan
Journal:  Int J Ophthalmol       Date:  2018-07-18       Impact factor: 1.779

3.  Comparison of corneal curvature and anterior chamber depth measurements using the manual keratometer, Lenstar LS 900 and the Pentacam.

Authors:  Omür Ö Uçakhan; Veysel Akbel; Zeynep Bıyıklı; Ayfer Kanpolat
Journal:  Middle East Afr J Ophthalmol       Date:  2013 Jul-Sep

4.  Comparison of Ocular Biometry Using New Swept-source Optical Coherence Tomography-based Optical Biometer with Other Devices.

Authors:  Young Joo Cho; Tae Hyung Lim; Kee Yong Choi; Beom Jin Cho
Journal:  Korean J Ophthalmol       Date:  2018-08

5.  Agreement between Pentacam and handheld Auto-Refractor/Keratometer for keratometry measurement.

Authors:  Hassan Hashemi; Samira Heydarian; Abbas Ali Yekta; Mohamadreza Aghamirsalim; Mahin Ahmadi-Pishkuhi; Mehrnaz Valadkhan; Hadi Ostadimoghaddam; Ahmad Ahmadzadeh Amiri; Mehdi Khabazkhoob
Journal:  J Optom       Date:  2019-07-10

6.  Time to Keratometric Stability After Pterygium Excision and the Associated Factors: A Clinical Perspective.

Authors:  Duangratn Niruthisard; Wasee Tulvatana; Vannarut Satitpitakul
Journal:  Clin Ophthalmol       Date:  2021-03-25

7.  Comparison of Anterior Segment Measurements with a New Multifunctional Unit and Five Other Devices.

Authors:  Bo Yi Kim; Ikhyun Jun
Journal:  Korean J Ophthalmol       Date:  2022-06-15

8.  Posterior corneal astigmatism: a review article.

Authors:  Seyed-Farzad Mohammadi; Masoud Khorrami-Nejad; Moein Hamidirad
Journal:  Clin Optom (Auckl)       Date:  2019-08-12
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.