| Literature DB >> 28846701 |
Joo Hyun1,2, Dong Hui Lim1,3, Doo Ri Eo1, Sungsoon Hwang1, Eui-Sang Chung4, Tae-Young Chung1.
Abstract
PURPOSE: To compare the efficacy and rotational stability after implantation of two types of toric implantable collamer lenses (Toric ICL™(TICL);V4 and V4c, STAAR Surgical Co.). STUDYEntities:
Mesh:
Year: 2017 PMID: 28846701 PMCID: PMC5573270 DOI: 10.1371/journal.pone.0183335
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Baseline characteristics of patients who underwent implantation of a toric implantable collamer lens (TICL: V4 TICL versus V4c TICL).
| V4 TICL | V4c TICL | P-value | |
|---|---|---|---|
| Number of patients (eyes) | 24 (24) | 24 (24) | |
| Mean age (range) (y) | 31.08 ± 7.78 (18 to 45) | 24.54 ± 7.91 (18 to 55) | 0.001 |
| Gender (Men:Women) | 9 eyes: 15 eyes | 4 eyes: 20 eyes | 0.193 |
| Mean follow-up (range) (month) | 7.64 ± 4.87 (1 to 18) | 7.38 ± 4.62 (1 to 17) | 0.869 |
| Mean MRSE (D) (range) | -10.68 ± 2.44 (-15.68 to -5.57) | -9.91 ± 2.98 (-14.25 to -4.13) | 0.386 |
| Mean refractive cylinder (D) (range) | 2.50 ± 1.24 (1.00 to 5.25) | 2.34 ± 0.76 (1.25 to 4.00) | 0.740 |
| Mean visual acuity (range) (logMAR) | |||
| ● UCVA | 1.32 ± 0.63 (0.40 to 2.00) | 1.55 ± 0.48 (0.70 to 2.00) | 0.198 |
| ● BSCVA | 0.06 ± 0.02 (0.00 to 0.30) | 0.05 ± 0.07 (0.00 to 0.20) | 0.721 |
| Intraocular pressure (range) (mmHg) | 15.15± 3.28 (8.90 to 21.00) | 17.33 ± 2.52 (13.00 to 21.50) | 0.022 |
| Endothelial cell count (/mm2) | 2879.46 ± 412.51 | 3224.33 ± 291.78 | 0.006 |
D = diopters; MRSE = manifest refractive spherical equivalent;UCVA = Uncorrected visual acuity; BSCVA = best-spectacle corrected visual acuity
*: Mann-Whitney U test;
†: Chi test
Comparison of postoperative visual outcomes between V4 and V4c toric implantable collamer lens (TICL) groups.
| Visual outcome | V4 TICL | V4c TICL | P-value* |
|---|---|---|---|
| Mean postoperative uncorrected visual acuity (logMAR) (range) | 0.04 ± 0.06 (0.00 to 0.15) | 0.01 ± 0.07 (-0.10 to 0.15) | 0.111 |
| Mean postoperative best-spectacle corrected visual acuity (logMAR) (range) | 0.01 ± 0.02 (0.00 to 0.05) | -0.03 ± 0.08 (-0.20 to 0.10) | 0.122 |
| Efficacy index | 1.06 | 1.09 | 0.251 |
| Safety index | 1.14 | 1.20 | 0.348 |
| Mean postoperative manifest refractive spherical equivalent (D) (range) | -0.41 ± 0.48 (-1.50 to 0.56) | -0.21 ± 0.39 (-1.25 to 0.38) | 0.067 |
| Mean postoperative refractive cylinder (D) (range) | 0.63 ± 0.33 (0.00 to 1.25) | 0.56 ± 0.29 (0.25 to 1.25) | 0.384 |
Fig 1Cumulative percentages of eyes attaining specified cumulative levels of uncorrected distance visual acuity after V4 and V4c toric implantable collamer lenses (TICLs) implantations.
Fig 2Scatter plots of the attempted versus the achieved manifest spherical equivalent (SEQ) after A) V4 and B) V4c toric implantable collamer lenses (TICLs) implantations.
Fig 3Percentages of eyes within different diopter ranges of the attempted spherical equivalent (SEQ) after V4 and V4c toric implantable collamer lenses (TICLs) implantations.
Fig 4Percentages of eyes attaining specified levels of astigmatism after V4 (A) and V4c (B) toric implantable collamer lenses (TICLs) implantations.
Fig 5Postoperative rotational stability of the V4 and V4c toric implantable collamer lens (TICL).
The angle represents the axis deviation including intraoperative misalignment of two types of TICL.
Intraoperative adjustment and postoperative rotation of the toric implantable collamer lenses.
| V4 TICL | V4c TICL | ||
|---|---|---|---|
| Power of ICL | |||
| ● Sphere (D) | -16.48 ± 3.24 (-23.00 to -9.50) | -12.27 ± 2.86 (-17.00 to -6.50) | <0.001 |
| ● Estimated Sphere (D)(Sphere*0.78) | -11.70 ± 4.53 (-17.94 to -7.41) | -12.27 ± 2.86 (-17.00 to -6.50) | 0.620 |
| ● Cylinder (D) | 2.83 ± 1.37 (1.00 to 6.00) | 2.19 ± 0.81 (1.00 to 4.00) | 0.113 |
| Mean amount of intraoperative adjustment(degree) | 7.75 ± 6.06 (0.00 to 21.00) | 3.00 ± 2.52 (0.00 to 11.00) | 0.006 |
| Mean postoperative rotation (degree) | 4.17 ± 3.31 (0 to 11.00) | 3.39 ± 2.36 (0.31 to 9.57) | 0.489 |
| Postoperative vault (μm) | 687.50 ± 232.65 | 674.71 ± 192.71 | 0.902 |
D = Diopter; ICL = Implantable collamer lens; TICL = Toric implantable collamer lens
*: Mann-Whitney U test
Vector analysis and comparison of the astigmatic change of two types of toric implantable collamer lenses (TICLs).
| V4 TICL | V4c TICL | ||
|---|---|---|---|
| TIA | 2.31 ± 1.24 (1.00 to 5.22) | 2.14 ± 0.77 (0.98 to 3.91) | 0.837 |
| SIA | 2.11 ± 1.09 (0.75 to 4.50) | 1.78 ± 0.70 (0.51 to 3.25) | 0.503 |
| DV | 0.52 ± 0.31 (0.11 to 1.22) | 0.40 ± 0.25 (0.02 to 1.09) | 0.257 |
| Magnitude of Error | -0.21 ± 0.53 (-1.19 to 0.99) | -0.36 ± 0.26 (-0.99 to 0.13) | 0.343 |
| Correction Index | 0.95 ± 0.32 (0.50 to 1.99) | 0.82 ± 0.14 (0.52 to 1.07) | 0.224 |
| Index of success | 0.26 ± 0.21 (0.06 to 1.00) | 0.19 ± 0.11 (0.01 to 0.39) | 0.353 |
TIA = target induced astigmatism; SIA = surgically induced astigmatism; DV = difference vector
*: Mann-Whitney U test
Spearman’s rho correlation between postoperative rotation of toric implantable collamer lens (TICL) and possible risk factors.
| Rotational stability | ||||
|---|---|---|---|---|
| V4 | V4c | |||
| r | r | |||
| Preoperative MRSE | -0.258 | 0.223 | -0.199 | 0.351 |
| Power of lens | ||||
| ● Sphere (D) | -0.334 | 0.110 | -0.167 | 0.436 |
| ● Cylinder (D) | 0.164 | 0.443 | -0.353 | 0.091 |
| Postoperative vault | 0.314 | 0.136 | 0.024 | 0.913 |
| Intraoperative adjustment (degree) | 0.041 | 0.848 | -0.153 | 0.474 |
MRSE = Manifest refractive spherical equivalent; D = Diopter