Literature DB >> 21733922

Early clinical outcomes of implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for moderate to high myopia.

Kimiya Shimizu1, Kazutaka Kamiya, Akihito Igarashi, Tetsu Shiratani.   

Abstract

AIM: To assess the early clinical outcomes of an ICL with a central hole (Hole ICL) implantation for the correction of moderate to high myopia.
METHODS: This study evaluated 20 eyes of 20 patients with spherical equivalents of -7.36 ± 2.13 D (mean ± SD) who underwent Hole ICL implantation. Before surgery and at 1 week and 1, 3 and 6 months after surgery, we assessed the safety, efficacy, predictability, stability and adverse events of the surgery.
RESULTS: Logarithm of the minimum angle of resolution (logMAR) uncorrected visual acuity and logMAR best spectacle-corrected visual acuity were -0.20 ± 0.12 and -0.25 ± 0.06, respectively, 6 months after surgery. The safety and efficacy indices were 1.13 ± 0.24 and 1.03 ± 0.30, respectively. At 6 months, 95%, and 100% eyes were within ± 0.5 and ± 1.0 D of the targeted correction, respectively. Change in manifest refraction from week 1 to month 6 was 0.06 ± 0.28 D. No significant rise in intraocular pressure (including pupillary block) or a secondary cataract occurred in any case during the period of observation.
CONCLUSIONS: Implantation of a newly developed Hole ICL offered good results for all measures of safety, efficacy, predictability and stability for the correction of moderate to high myopic errors, even without peripheral iridectomy, suggesting its viability as a surgical option for the treatment of such eyes.

Entities:  

Mesh:

Year:  2011        PMID: 21733922     DOI: 10.1136/bjophthalmol-2011-300148

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  52 in total

1.  [Can the implantable collamer lens with AquaPORT technology safely prevent an angle block? Early experiences in the Homburg/Saar refractive surgery center].

Authors:  T Tsintarakis; T Eppig; A Langenbucher; B Seitz; M El-Husseiny
Journal:  Ophthalmologe       Date:  2015-05       Impact factor: 1.059

2.  A case of hypermature cataract formation following implantation of an implantable collamer lens with an Aquaport.

Authors:  Kyu-Yeon Hwang; Sung A Lim; So-Hyang Chung
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

3.  Theoretical study on the need for laser iridotomy in an implantable collamer lens with a hole using computational fluid dynamics.

Authors:  T Kawamorita; K Shimizu; N Shoji
Journal:  Eye (Lond)       Date:  2017-01-20       Impact factor: 3.775

4.  Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens.

Authors:  Min Ji Park; Hye Min Jeon; Kyoung Heon Lee; Sang Youp Han
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

5.  Effect of hole size on fluid dynamics of a posterior-chamber phakic intraocular lens with a central perforation by using computational fluid dynamics.

Authors:  Takushi Kawamorita; Kimiya Shimizu; Nobuyuki Shoji
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-02-19       Impact factor: 3.117

6.  [Intraocular pressure after implantation of an ICL with aquaport : Development of intraocular pressure after implantation of an ICL (model V4c) with aquaport without iridotomy].

Authors:  B Repplinger; T Kohnen
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

Review 7.  Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation.

Authors:  Hao Zhang; Rui Gong; Xiaolan Zhang; Yingping Deng
Journal:  Int Ophthalmol       Date:  2022-06-22       Impact factor: 2.029

8.  Effects of tilt and decentration of Visian Implantable Collamer Lens (ICL V4c) on visual quality: an observational study.

Authors:  Lingling Niu; Zhe Zhang; Huamao Miao; Jing Zhao; Meiyan Li; Ji C He; Peijun Yao; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2022-07-05       Impact factor: 2.086

9.  Comparison of optical quality and intraocular scattering after posterior chamber phakic intraocular lens with and without a central hole (Hole ICL and Conventional ICL) implantation using the double-pass instrument.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Aya Saito; Akihito Igarashi; Hidenaga Kobashi
Journal:  PLoS One       Date:  2013-06-25       Impact factor: 3.240

10.  Visian implantable contact lens versus AcrySof Cachet phakic intraocular lenses: comparison of aberrmetric profiles.

Authors:  Mohamed Hm Hosny; Ahmad Mm Shalaby
Journal:  Clin Ophthalmol       Date:  2013-07-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.