Literature DB >> 23688878

Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction.

José F Alfonso1, Carlos Lisa, Luis Fernández-Vega Cueto, Lurdes Belda-Salmerón, David Madrid-Costa, Robert Montés-Micó.   

Abstract

PURPOSE: To evaluate the efficacy, predictability, safety, and stability of a new-model posterior chamber Implantable Collamer Lens phakic intraocular lens (pIOL) (V4c Visian) to correct myopia.
SETTING: Private practice, Oviedo, Spain.
DESIGN: Case series.
METHODS: This study enrolled patients who had implantation of a new pIOL design with a central hole for more natural aqueous flow, eliminating the need for neodymium:YAG iridotomy or peripheral iridectomy. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refractive error, intraocular pressure (IOP), endothelial cell count, central vault, and adverse events were evaluated 6 months postoperatively.
RESULTS: The study enrolled 138 eyes (70 patients). The mean spherical equivalent decreased from -8.73 diopters (D) ± 2.54 (SD) preoperatively to -0.03 ± 0.19 D 6 months postoperatively; 98.5% of eyes were within ±0.50 D and 100% of eyes were within ±1.00 D. The mean UDVA and CDVA were 20/20 or better in 92.1% and 95.0% of eyes, respectively, at 6 months. The safety and efficacy indices were 1.01 and 1.00, respectively. Postoperatively, the IOP remained stable over time. No significant rises in IOP (including pupillary block) and no secondary cataract were found. After 6 months, the mean vault was 482.7 ± 210.5 μm (range 90 to 970 μm) and the mean endothelial cell loss was 8.5%.
CONCLUSIONS: Implantation of the pIOL was effective, predictable, safe, and stable for the correction of moderate to high myopic errors. This design, which avoids iridotomy or iridectomy, provided good IOP outcomes. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23688878     DOI: 10.1016/j.jcrs.2013.01.036

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  29 in total

1.  [Can the implantable collamer lens with AquaPORT technology safely prevent an angle block? Early experiences in the Homburg/Saar refractive surgery center].

Authors:  T Tsintarakis; T Eppig; A Langenbucher; B Seitz; M El-Husseiny
Journal:  Ophthalmologe       Date:  2015-05       Impact factor: 1.059

2.  Theoretical study on the need for laser iridotomy in an implantable collamer lens with a hole using computational fluid dynamics.

Authors:  T Kawamorita; K Shimizu; N Shoji
Journal:  Eye (Lond)       Date:  2017-01-20       Impact factor: 3.775

3.  Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens.

Authors:  Min Ji Park; Hye Min Jeon; Kyoung Heon Lee; Sang Youp Han
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

4.  Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults.

Authors:  Jing Zhang; Jing Zhuang; Ke-Ming Yu
Journal:  Int J Ophthalmol       Date:  2018-11-18       Impact factor: 1.779

5.  Phakic posterior chamber intraocular lens for unilateral high myopic amblyopia in Chinese pediatric patients.

Authors:  Jing Zhang; Jin-Rong Li; Zi-Dong Chen; Min-Bin Yu; Ke-Ming Yu
Journal:  Int J Ophthalmol       Date:  2016-12-18       Impact factor: 1.779

6.  [Intraocular pressure after implantation of an ICL with aquaport : Development of intraocular pressure after implantation of an ICL (model V4c) with aquaport without iridotomy].

Authors:  B Repplinger; T Kohnen
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

Review 7.  Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation.

Authors:  Hao Zhang; Rui Gong; Xiaolan Zhang; Yingping Deng
Journal:  Int Ophthalmol       Date:  2022-06-22       Impact factor: 2.029

8.  Inter-eye and postoperative prediction of vault after implantation of EVO + Visian phakic implantable collamer lens.

Authors:  Elena Martínez-Plaza; Alberto López-Miguel; Alberto López-de la Rosa; Miguel J Maldonado
Journal:  Int Ophthalmol       Date:  2022-10-19       Impact factor: 2.029

9.  Implantable collamer lens V4b and V4c for correction of high myopia.

Authors:  Vipul Bhandari; Smitha Karandikar; Jagdeesh K Reddy; Kirti Relekar
Journal:  J Curr Ophthalmol       Date:  2016-02-09

Review 10.  Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens.

Authors:  Mark Packer
Journal:  Clin Ophthalmol       Date:  2016-06-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.