Literature DB >> 28572693

Fundamental limits of image registration performance: Effects of image noise and resolution in CT-guided interventions.

M D Ketcha1, T de Silva1, R Han1, A Uneri2, J Goerres1, M Jacobson1, S Vogt3, G Kleinszig3, J H Siewerdsen1,2,4.   

Abstract

PURPOSE: In image-guided procedures, image acquisition is often performed primarily for the task of geometrically registering information from another image dataset, rather than detection / visualization of a particular feature. While the ability to detect a particular feature in an image has been studied extensively with respect to image quality characteristics (noise, resolution) and is an ongoing, active area of research, comparatively little has been accomplished to relate such image quality characteristics to registration performance.
METHODS: To establish such a framework, we derived Cramer-Rao lower bounds (CRLB) for registration accuracy, revealing the underlying dependencies on image variance and gradient strength. The CRLB was analyzed as a function of image quality factors (in particular, dose) for various similarity metrics and compared to registration accuracy using CT images of an anthropomorphic head phantom at various simulated dose levels. Performance was evaluated in terms of root mean square error (RMSE) of the registration parameters.
RESULTS: Analysis of the CRLB shows two primary dependencies: 1) noise variance (related to dose); and 2) sum of squared image gradients (related to spatial resolution and image content). Comparison of the measured RMSE to the CRLB showed that the best registration method, RMSE achieved the CRLB to within an efficiency factor of 0.21, and optimal estimators followed the predicted inverse proportionality between registration performance and radiation dose.
CONCLUSIONS: Analysis of the CRLB for image registration is an important step toward understanding and evaluating an intraoperative imaging system with respect to a registration task. While the CRLB is optimistic in absolute performance, it reveals a basis for relating the performance of registration estimators as a function of noise content and may be used to guide acquisition parameter selection (e.g., dose) for purposes of intraoperative registration.

Entities:  

Keywords:  CT/CBCT; Fisher Information; Image Guided Procedures; Image Quality; Image Registration; Performance Limits

Year:  2017        PMID: 28572693      PMCID: PMC5448715          DOI: 10.1117/12.2256025

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  10 in total

1.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter.

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  2001-02       Impact factor: 4.071

2.  The distribution of target registration error in rigid-body point-based registration.

Authors:  J M Fitzpatrick; J B West
Journal:  IEEE Trans Med Imaging       Date:  2001-09       Impact factor: 10.048

3.  Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography).

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

4.  Fundamental performance limits in image registration.

Authors:  Dirk Robinson; Peyman Milanfar
Journal:  IEEE Trans Image Process       Date:  2004-09       Impact factor: 10.856

5.  Optimization of mutual information for multiresolution image registration.

Authors:  P Thévenaz; M Unser
Journal:  IEEE Trans Image Process       Date:  2000       Impact factor: 10.856

6.  Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

7.  Objective assessment of image quality. II. Fisher information, Fourier crosstalk, and figures of merit for task performance.

Authors:  H H Barrett; J L Denny; R F Wagner; K J Myers
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1995-05       Impact factor: 2.129

8.  Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance.

Authors:  Grace J Gang; Junghoon Lee; J Webster Stayman; Daniel J Tward; W Zbijewski; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

9.  The Design of SimpleITK.

Authors:  Bradley C Lowekamp; David T Chen; Luis Ibáñez; Daniel Blezek
Journal:  Front Neuroinform       Date:  2013-12-30       Impact factor: 4.081

10.  Technical Note: spektr 3.0-A computational tool for x-ray spectrum modeling and analysis.

Authors:  J Punnoose; J Xu; A Sisniega; W Zbijewski; J H Siewerdsen
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

  10 in total
  2 in total

1.  Effects of Image Quality on the Fundamental Limits of Image Registration Accuracy.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Joseph Goerres; Matthew W Jacobson; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2017-07-11       Impact factor: 10.048

2.  Spine Surgery Supported by Augmented Reality.

Authors:  Barbara Carl; Miriam Bopp; Benjamin Saß; Mirza Pojskic; Benjamin Voellger; Christopher Nimsky
Journal:  Global Spine J       Date:  2020-05-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.