Modeling and design of a cone-beam CT head scanner using task-based imaging performance optimization.

J Xu1, A Sisniega, W Zbijewski, H Dang, J W Stayman, X Wang, D H Foos, N Aygun, V E Koliatsos, J H Siewerdsen.   

Abstract

Detection of acute intracranial hemorrhage (ICH) is important for diagnosis and treatment of traumatic brain injury, stroke, postoperative bleeding, and other head and neck injuries. This paper details the design and development of a cone-beam CT (CBCT) system developed specifically for the detection of low-contrast ICH in a form suitable for application at the point of care. Recognizing such a low-contrast imaging task to be a major challenge in CBCT, the system design began with a rigorous analysis of task-based detectability including critical aspects of system geometry, hardware configuration, and artifact correction. The imaging performance model described the three-dimensional (3D) noise-equivalent quanta using a cascaded systems model that included the effects of scatter, scatter correction, hardware considerations of complementary metal-oxide semiconductor (CMOS) and flat-panel detectors (FPDs), and digitization bit depth. The performance was analyzed with respect to a low-contrast (40-80 HU), medium-frequency task representing acute ICH detection. The task-based detectability index was computed using a non-prewhitening observer model. The optimization was performed with respect to four major design considerations: (1) system geometry (including source-to-detector distance (SDD) and source-to-axis distance (SAD)); (2) factors related to the x-ray source (including focal spot size, kVp, dose, and tube power); (3) scatter correction and selection of an antiscatter grid; and (4) x-ray detector configuration (including pixel size, additive electronics noise, field of view (FOV), and frame rate, including both CMOS and a-Si:H FPDs). Optimal design choices were also considered with respect to practical constraints and available hardware components. The model was verified in comparison to measurements on a CBCT imaging bench as a function of the numerous design parameters mentioned above. An extended geometry (SAD = 750 mm, SDD  = 1100 mm) was found to be advantageous in terms of patient dose (20 mGy) and scatter reduction, while a more isocentric configuration (SAD = 550 mm, SDD  = 1000 mm) was found to give a more compact and mechanically favorable configuration with minor tradeoff in detectability. An x-ray source with a 0.6 mm focal spot size provided the best compromise between spatial resolution requirements and x-ray tube power. Use of a modest anti-scatter grid (8:1 GR) at a 20 mGy dose provided slight improvement (~5-10%) in the detectability index, but the benefit was lost at reduced dose. The potential advantages of CMOS detectors over FPDs were quantified, showing that both detectors provided sufficient spatial resolution for ICH detection, while the former provided a potentially superior low-dose performance, and the latter provided the requisite FOV for volumetric imaging in a centered-detector geometry. Task-based imaging performance modeling provides an important starting point for CBCT system design, especially for the challenging task of ICH detection, which is somewhat beyond the capabilities of existing CBCT platforms. The model identifies important tradeoffs in system geometry and hardware configuration, and it supports the development of a dedicated CBCT system for point-of-care application. A prototype suitable for clinical studies is in development based on this analysis.

Entities:  

Mesh:

Year:  2016        PMID: 27025783     DOI: 10.1088/0031-9155/61/8/3180

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Effects of Image Quality on the Fundamental Limits of Image Registration Accuracy.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Joseph Goerres; Matthew W Jacobson; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2017-07-11       Impact factor: 10.048

2.  Task-driven source-detector trajectories in cone-beam computed tomography: I. Theory and methods.

Authors:  J Webster Stayman; Sarah Capostagno; Grace J Gang; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-02

3.  Multi-resolution statistical image reconstruction for mitigation of truncation effects: application to cone-beam CT of the head.

Authors:  Hao Dang; J Webster Stayman; Alejandro Sisniega; Wojciech Zbijewski; Jennifer Xu; Xiaohui Wang; David H Foos; Nafi Aygun; Vassilis E Koliatsos; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-12-29       Impact factor: 3.609

4.  Correction of patient motion in cone-beam CT using 3D-2D registration.

Authors:  S Ouadah; M Jacobson; J W Stayman; T Ehtiati; C Weiss; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-11-09       Impact factor: 3.609

5.  Cone-beam CT for imaging of the head/brain: Development and assessment of scanner prototype and reconstruction algorithms.

Authors:  P Wu; A Sisniega; J W Stayman; W Zbijewski; D Foos; X Wang; N Khanna; N Aygun; R D Stevens; J H Siewerdsen
Journal:  Med Phys       Date:  2020-04-03       Impact factor: 4.071

6.  Predicting image properties in penalized-likelihood reconstructions of flat-panel CBCT.

Authors:  Wenying Wang; Grace J Gang; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Med Phys       Date:  2018-11-20       Impact factor: 4.071

7.  Spatial Resolution and Noise Prediction in Flat-Panel Cone-Beam CT Penalized-likelihood Reconstruction.

Authors:  W Wang; G J Gang; J H Siewerdsen; J W Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.