Literature DB >> 28362638

Task-driven optimization of CT tube current modulation and regularization in model-based iterative reconstruction.

Grace J Gang1, Jeffrey H Siewerdsen, J Webster Stayman.   

Abstract

Tube current modulation (TCM) is routinely adopted on diagnostic CT scanners for dose reduction. Conventional TCM strategies are generally designed for filtered-backprojection (FBP) reconstruction to satisfy simple image quality requirements based on noise. This work investigates TCM designs for model-based iterative reconstruction (MBIR) to achieve optimal imaging performance as determined by a task-based image quality metric. Additionally, regularization is an important aspect of MBIR that is jointly optimized with TCM, and includes both the regularization strength that controls overall smoothness as well as directional weights that permits control of the isotropy/anisotropy of the local noise and resolution properties. Initial investigations focus on a known imaging task at a single location in the image volume. The framework adopts Fourier and analytical approximations for fast estimation of the local noise power spectrum (NPS) and modulation transfer function (MTF)-each carrying dependencies on TCM and regularization. For the single location optimization, the local detectability index (d') of the specific task was directly adopted as the objective function. A covariance matrix adaptation evolution strategy (CMA-ES) algorithm was employed to identify the optimal combination of imaging parameters. Evaluations of both conventional and task-driven approaches were performed in an abdomen phantom for a mid-frequency discrimination task in the kidney. Among the conventional strategies, the TCM pattern optimal for FBP using a minimum variance criterion yielded a worse task-based performance compared to an unmodulated strategy when applied to MBIR. Moreover, task-driven TCM designs for MBIR were found to have the opposite behavior from conventional designs for FBP, with greater fluence assigned to the less attenuating views of the abdomen and less fluence to the more attenuating lateral views. Such TCM patterns exaggerate the intrinsic anisotropy of the MTF and NPS as a result of the data weighting in MBIR. Directional penalty design was found to reinforce the same trend. The task-driven approaches outperform conventional approaches, with the maximum improvement in d' of 13% given by the joint optimization of TCM and regularization. This work demonstrates that the TCM optimal for MBIR is distinct from conventional strategies proposed for FBP reconstruction and strategies optimal for FBP are suboptimal and may even reduce performance when applied to MBIR. The task-driven imaging framework offers a promising approach for optimizing acquisition and reconstruction for MBIR that can improve imaging performance and/or dose utilization beyond conventional imaging strategies.

Entities:  

Mesh:

Year:  2017        PMID: 28362638      PMCID: PMC5738673          DOI: 10.1088/1361-6560/aa6a97

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies.

Authors:  M Gies; W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Penalized maximum-likelihood image reconstruction for lesion detection.

Authors:  Jinyi Qi; Ronald H Huesman
Journal:  Phys Med Biol       Date:  2006-08-02       Impact factor: 3.609

3.  Fast predictions of variance images for fan-beam transmission tomography with quadratic regularization.

Authors:  Yingying Zhang-O'Connor; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2007-03       Impact factor: 10.048

4.  The feasibility of a piecewise-linear dynamic bowtie filter.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

5.  Task-Based Design of Fluence Field Modulation in CT for Model-Based Iterative Reconstruction.

Authors:  Grace J Gang; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr       Date:  2016-07

6.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

7.  Fluence-Field Modulated X-ray CT using Multiple Aperture Devices.

Authors:  J Webster Stayman; Aswin Mathews; Wojciech Zbijewski; Grace Gang; Jeffrey Siewerdsen; Satomi Kawamoto; Ira Blevis; Reuven Levinson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-22

8.  Regularization design in penalized maximum-likelihood image reconstruction for lesion detection in 3D PET.

Authors:  Li Yang; Jian Zhou; Andrea Ferrero; Ramsey D Badawi; Jinyi Qi
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

Review 9.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

10.  A mathematical model platform for optimizing a multiprojection breast imaging system.

Authors:  Amarpreet S Chawla; Ehsan Samei; Robert S Saunders; Joseph Y Lo; Jay A Baker
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

View more
  9 in total

1.  Dynamic fluence field modulation for miscentered patients in computed tomography.

Authors:  Andrew Mao; Grace J Gang; William Shyr; Reuven Levinson; Jeffrey H Siewerdsen; Satomi Kawamoto; J Webster Stayman
Journal:  J Med Imaging (Bellingham)       Date:  2018-10-24

2.  Effects of Image Quality on the Fundamental Limits of Image Registration Accuracy.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Joseph Goerres; Matthew W Jacobson; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2017-07-11       Impact factor: 10.048

3.  Task-driven source-detector trajectories in cone-beam computed tomography: I. Theory and methods.

Authors:  J Webster Stayman; Sarah Capostagno; Grace J Gang; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-02

4.  Task-driven source-detector trajectories in cone-beam computed tomography: II. Application to neuroradiology.

Authors:  Sarah Capostagno; J Webster Stayman; Matthew Jacobson; Tina Ehtiati; Clifford R Weiss; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-09

5.  Dual source hybrid spectral micro-CT using an energy-integrating and a photon-counting detector.

Authors:  M D Holbrook; D P Clark; C T Badea
Journal:  Phys Med Biol       Date:  2020-10-21       Impact factor: 3.609

6.  Task-Driven Optimization of Fluence Field and Regularization for Model-Based Iterative Reconstruction in Computed Tomography.

Authors:  Grace J Gang; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2017-10-16       Impact factor: 10.048

7.  A scanner-specific framework for simulating CT images with tube current modulation.

Authors:  Giavanna Jadick; Ehsan Abadi; Brian Harrawood; Shobhit Sharma; W Paul Segars; Ehsan Samei
Journal:  Phys Med Biol       Date:  2021-09-13       Impact factor: 3.609

8.  Predicting image properties in penalized-likelihood reconstructions of flat-panel CBCT.

Authors:  Wenying Wang; Grace J Gang; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Med Phys       Date:  2018-11-20       Impact factor: 4.071

9.  Low-dose cone-beam CT via raw counts domain low-signal correction schemes: Performance assessment and task-based parameter optimization (Part II. Task-based parameter optimization).

Authors:  Daniel Gomez-Cardona; John W Hayes; Ran Zhang; Ke Li; Juan Pablo Cruz-Bastida; Guang-Hong Chen
Journal:  Med Phys       Date:  2018-04-06       Impact factor: 4.071

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.