Literature DB >> 28593931

Performance characterization of a 3D liquid scintillation detector for discrete spot scanning proton beam systems.

Chinmay D Darne1, Fahed Alsanea, Daniel G Robertson, Narayan Sahoo, Sam Beddar.   

Abstract

Existing systems for proton beam dosimetry are limited in their ability to provide a complete, accurate, and detailed account of volumetric dose distribution. In this work, we describe the design and development of a portable, fast, and reusable liquid scintillator-based three-dimensional (3D) optical detection system for use in proton therapy. Our long-term goal is to use this system clinically for beam characterization, dosimetry, and quality assurance studies of discrete spot scanning proton beam systems. The system used a 20  ×  20  ×  20 cm3 liquid scintillator volume. Three mutually orthogonal cameras surrounding this volume captured scintillation photons emitted in response to the proton beams. The cameras exhibited a mean spatial resolution of 0.21 mm over the complete detection volume and a temporal resolution of 11 ms. The system is shown to be capable of capturing all 94 beam energies delivered by a synchrotron and performing rapid beam range measurements with a mean accuracy of 0.073  ±  0.030 mm over all energies. The range measurement uncertainty for doses less than 1 cGy was found to be  ±0.355 mm, indicating high precision for low dose detection. Finally, we demonstrated that using multiple cameras allowed for the precise locations of the delivered beams to be tracked in 3D. We conclude that this detector is capable of real-time and accurate tracking of dynamic spot beam deliveries in 3D. The high-resolution light profiles it generates will be useful for future 3D construction of dose maps.

Entities:  

Mesh:

Year:  2017        PMID: 28593931      PMCID: PMC5737629          DOI: 10.1088/1361-6560/aa780b

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system.

Authors:  L Archambault; F Poenisch; N Sahoo; D Robertson; A Lee; M T Gillin; R Mohan; S Beddar
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  Development and characterization of a tissue equivalent plastic scintillator based dosimetry system.

Authors:  M P Petric; J L Robar; B G Clark
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

3.  Preliminary investigations on the determination of three-dimensional dose distributions using scintillator blocks and optical tomography.

Authors:  Florian Kroll; Jörg Pawelke; Leonhard Karsch
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

4.  Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams.

Authors:  Sam Beddar; Louis Archambault; Narayan Sahoo; Falk Poenisch; George T Chen; Michael T Gillin; Radhe Mohan
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

5.  Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston.

Authors:  Michael T Gillin; Narayan Sahoo; Martin Bues; George Ciangaru; Gabriel Sawakuchi; Falk Poenisch; Bijan Arjomandy; Craig Martin; Uwe Titt; Kazumichi Suzuki; Alfred R Smith; X Ronald Zhu
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

6.  Intensity modulated proton therapy.

Authors:  H M Kooy; C Grassberger
Journal:  Br J Radiol       Date:  2015-05-27       Impact factor: 3.039

7.  Calculations and measurements of the scintillator-to-water stopping power ratio of liquid scintillators for use in proton radiotherapy.

Authors:  W Scott Ingram; Daniel Robertson; Sam Beddar
Journal:  Nucl Instrum Methods Phys Res A       Date:  2015-03-11       Impact factor: 1.455

8.  Optical artefact characterization and correction in volumetric scintillation dosimetry.

Authors:  Daniel Robertson; Cheukkai Hui; Louis Archambault; Radhe Mohan; Sam Beddar
Journal:  Phys Med Biol       Date:  2013-12-10       Impact factor: 3.609

9.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration.

Authors:  A S Beddar; T R Mackie; F H Attix
Journal:  Phys Med Biol       Date:  1992-10       Impact factor: 3.609

10.  Issues involved in the quantitative 3D imaging of proton doses using optical CT and chemical dosimeters.

Authors:  Simon Doran; Tina Gorjiara; Andrzej Kacperek; John Adamovics; Zdenka Kuncic; Clive Baldock
Journal:  Phys Med Biol       Date:  2015-01-02       Impact factor: 3.609

View more
  7 in total

1.  Ionization quenching correction for a 3D scintillator detector exposed to scanning proton beams.

Authors:  Fahed Alsanea; Chinmay Darne; Daniel Robertson; Sam Beddar
Journal:  Phys Med Biol       Date:  2020-04-06       Impact factor: 3.609

2.  A novel proton-integrating radiography system design using a monolithic scintillator detector: experimental studies.

Authors:  Chinmay D Darne; Daniel G Robertson; Fahed Alsanea; Charles-Antoine Collins-Fekete; Sam Beddar
Journal:  Nucl Instrum Methods Phys Res A       Date:  2021-12-16       Impact factor: 1.455

Review 3.  Ultra-high dose rate electron beams and the FLASH effect: From preclinical evidence to a new radiotherapy paradigm.

Authors:  Emil Schüler; Munjal Acharya; Pierre Montay-Gruel; Billy W Loo; Marie-Catherine Vozenin; Peter G Maxim
Journal:  Med Phys       Date:  2022-01-19       Impact factor: 4.506

4.  Optically stimulated luminescence in state-of-the-art LYSO:Ce scintillators enables high spatial resolution 3D dose imaging.

Authors:  Mads L Jensen; Rosana M Turtos; Jacob S Nyemann; Ludvig P Muren; Brian Julsgaard; Peter Balling
Journal:  Sci Rep       Date:  2022-05-18       Impact factor: 4.996

5.  A proton imaging system using a volumetric liquid scintillator: a preliminary study.

Authors:  Chinmay D Darne; Fahed Alsanea; Daniel G Robertson; Fada Guan; Tinsu Pan; David Grosshans; Sam Beddar
Journal:  Biomed Phys Eng Express       Date:  2019-07-12

6.  A GEMPix-based integrated system for measurements of 3D dose distributions in water for carbon ion scanning beam radiotherapy.

Authors:  Johannes Leidner; Mario Ciocca; Andrea Mairani; Fabrizio Murtas; Marco Silari
Journal:  Med Phys       Date:  2020-03-21       Impact factor: 4.071

7.  Development of a time-resolved mirrorless scintillation detector.

Authors:  Wonjoong Cheon; Hyunuk Jung; Moonhee Lee; Jinhyeop Lee; Sung Jin Kim; Sungkoo Cho; Youngyih Han
Journal:  PLoS One       Date:  2021-02-12       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.